background image

8

IOM CLUSTER BAR MANUAL

964000.5.0

2.0 Installation

7/8” REF

1-1/8” REF

1” REF

1-5/32 REF

Hanger Clamp

3-5/32” REF

8” MIN
18” MAX

75’-

96’-0” Copper
141’-0” Steel

Legend

Hager Clamp

End Cover

Expansion

Anchor Clamp

Straight Run

Figure 11

Anchor Clamps

 

Figure 10

2.6  Expansion Section

2.6.1  

Note: 

 Location of expansion sections is important!  If no installation 

drawings for location of expansion sections, install as shown in Figure 11 
above.  Mount  expansion sections halfway between anchor points.  See 
installation drawing for placement.  

Special Note:

  Expansion sections will not operate on curves.    

2.6.2  Maximum distance between expansions are as follows:  

2.6.3  Attach expansion section in same manner as conductor bar.  Set 
gaps according to the following chart:

Copper

96 ft.

Galvanized Steel

141 ft.

Bar Temperature

Gap Setting (in.)

(Degrees F)

(Dim “X”. Between

ends of Conductors.)

110

3.25

100

3.36

90

3.47

80

3.58

70

3.68

60

3.80

50

3.91

40

4.02

30

4.13

Expansion Section

 

Figure 12

19/32”

3/16”

7/16”

3/16”

3/16”

View A-A

View B-B 

View C-C

A

B

C

A

B

C

1-1/8”

REF

3/4”

Gap Setting-Dim “X”

1/2” REF

3”

9-1/2” REF

6’-0” Expansion Shown

Side View

1” REF

1” REF

Содержание Cluster Bar

Страница 1: ...IOM CLUSTER BAR MANUAL 964000 5 0 1 Conductor Bar Manual Cluster Bar...

Страница 2: ...se once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guarantee or warranty a...

Страница 3: ...Splices 2 3 Field Cutting 2 4 Powerfeed 2 5 Anchor Clamps 2 6 Expansion Section 2 7 End Cap 2 8 Transfer Cap 2 9 Collector Mounting Dimensions 3 0 Maintenance 3 1 Warning 3 2 Atmospheric Conditions F...

Страница 4: ...Administration OSHA etc and city or local ordinances When using electrical power the law imposes the general obligation to use care to protect against accidental injury or damage to properties 2 0 Ins...

Страница 5: ...ounting Bkrt By Others Mounting Surface 3 4 REF 1 3 16 REF WEB BRACKET 2 1 2 REF 3 4 REF 1 1 4 REF 5 REF 3 1 8 REF 3 8 REF 2 1 4 REF 3 4 REF TYP 3 4 REF Contact Surface 3 8 REF 2 1 4 REF 1 1 2 MIN 4 1...

Страница 6: ...see Figure 5 2 2 Splices 2 2 1 Crimp Splices 2 2 1 1 One end of each 15 length of Cluster Bar has a factory attached crimp joint 2 2 1 2 To join two conductors slide the end without a splice into the...

Страница 7: ...ainer Cap Powerfeed Kit Assembly Figure 7 Figure 8 19 32 1 7 16 13 16 1 2 1 5 8 8 AWG or 10 AWG 2 4 Powerfeed 2 4 1 Locate powerfeed at a joint or end or install powerfeed at any point along a straigh...

Страница 8: ...ay between anchor points See installation drawing for placement Special Note Expansion sections will not operate on curves 2 6 2 Maximum distance between expansions are as follows 2 6 3 Attach expansi...

Страница 9: ...ery six months after the first year of service 3 3 Collectors 3 3 1 Any accumulation of dirt or dust should be removed from the collector 3 3 2 Replace worn collector shoes 3 3 3 Check spring tension...

Страница 10: ...Oper Position Lateral Movement 1 7 13 16 REF Channel Mount Figure 17 1 4 REF 8 REF Staff Collector Mount Figure 16 1 5 8 7 16 4 1 8 2 1 2 REF 1 3 16 1 15 32 2 3 16 31 32 O 344 3 1 1 8 Stroke Contact...

Страница 11: ...uster Bar Conductor Troubleshooting Problem Probable Cause Solution Shoes wearing unevenly Collector not mounted directly under conductor Square bar is rotated out of square Tighten joint check hanger...

Страница 12: ...12 IOM CLUSTER BAR MANUAL 964000 5 0 5 0 Typical Installations...

Страница 13: ...13 IOM CLUSTER BAR MANUAL 964000 5 0 Notes...

Страница 14: ...14 IOM CLUSTER BAR MANUAL 964000 5 0 Notes...

Страница 15: ...15 IOM CLUSTER BAR MANUAL 964000 5 0 Notes...

Страница 16: ...IOM CLUSTER BAR MANUAL 964000 5 0 Contact us for our Global Sales Offices www conductix us Conductix Wampfler 2017 Subject to Technical Modifications Without Prior Notice 16...

Отзывы: