5.0 Operation

5.1  General Precautions

5.1.1  After operating, please press EMS (Emergency Mushroom Stop) 
mushroom to shut off main power in the receiver remove transmitter key.

5.1.2  Stop operating when irregular response occurs due 
to insufficient transmitter power, beyond the remote control 
range, or severe interference.

5.1.3  

Remove the batteries when the equipment is not going to be 

used for a long period of time.

5.1.4  Operators must be properly trained and certified, understanding 
safe operation of the machine and this radio control.

5.1.5  Operator must be familiar with emergency procedures 
before operating (See Section 5.4).

5.1.6  Transmitter is durable and weather-resistant, but care should be 
taken not to subject it to severe impacts or undue abuse.

5.1.7  This product is suitable for use in industrial environments. Proper 
care and maintenance will extend system’s life.

5.1.8  Check EMS mushroom and the other security functions of entire 
system before daily operation, including (but not limited to) switches, 
E-Stop operation, etc.

5.1.9  Stop operating if the operator’s view is not clear of machine or 
load.

5.1.10  Press EMS mushroom when malfunctions or abnormal conditions 
occur.

5.2  Standard Operation

5.2.1  Default Power On Procedure

1.  Rotate EMS mushroom clockwise and pull out.
2.  Turn rotary key switch clockwise to “ON” position.
3.  Continue to turn key switch to “START” position in order to turn on 
power (after releasing the rotary key switch, it will  automatically return to 
the “ON” position).

5.2.2  Transmitter Power Indication

Transmitter has power indication function with LED display.

  

“Green Color Flashing”  Sufficient power to operate transmitter 
(In order to save power, one can program to turn off LED 

 

display when power level is sufficient).

  

“Red Color Flashing” Insufficient Power.  Transmitter will send 
out an emergency stop signal to the receiver due to insufficient 
power. Operator should avoid this situation in order to maintain 
operation safely.

Содержание 701L10001

Страница 1: ...L10 SERIES RADIO CONTROL MANUAL PN 701L10005 1 5 1 Radio Control Manual Series L10...

Страница 2: ...hall arise once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guarantee or wa...

Страница 3: ...tion Preparation 4 2 2 Installation Procedure 4 3 Transmitter Setup 4 3 1 Procedure 5 0 Operation 5 1 General Precautions 5 2 Standard Operation 5 2 1 Power on Procedure 5 2 2 TX Power Indication 5 3...

Страница 4: ...improper operation ignorance of environmental specifications and or improper software interfacing 1 5 Remarks 1 5 1 No other warranty is expressed or implied except for the above mentioned The remedi...

Страница 5: ...use to avoid accidental pressing of buttons 2 2 8 The crane should be equipped with mainline contactor limit switches and other require safety devices as dictated by CMAA OSHA or all other applicable...

Страница 6: ...equency drives and power cables shown on page 5 4 1 8 Coil suppressors must be installed on all contactor coil and relay coils Conductix Wampfler recommends RC type suppressors Conductix Wampfler Part...

Страница 7: ...ding to the receiver s wiring diagram and control contact diagram 5 Secure the cables between the receiver and crane so that the cable sheath will not wear out due to vibration of the crane 6 Turn on...

Страница 8: ...will extend system s life 5 1 8 Check EMS mushroom and the other security functions of entire system before daily operation including but not limited to switches E Stop operation etc 5 1 9 Stop operat...

Страница 9: ...a check mark V and please make sure not to replace a VHF crystal unit into UHF PC board or vice versa 5 2 3 1 Instructions 1 Pry up the crystal unit with a flat screwdriver 2 Remove the crystal unit f...

Страница 10: ...ress and hold the transmitter EMS button b Press UP push button and hold it c Press DOWN push button 4 times and release EMS UP push buttons when the red light on the transmitter is flashing d Start t...

Страница 11: ...impossible to Power ON the radio system 4 Maintenance technicians can use these error messages However we recommend the technician replace only the module The defective module should be returned to t...

Страница 12: ...etween Pushbutton and Relay Output 7 2 1 SAGA1 L10 only Up Down is with 4 relays others with 3 Their corresponding relation is shown as below Relay is on Relay is off UP DOWN 1 Normal Normal 1st Step...

Страница 13: ...ond step pushbutton must be pressed and held when pushing or turning Start pushbutton or key to reach third speed 8 Digital Acce Digital Acce 1st Step 2nd Step 1st Step 2nd Step 3rd Step 4th Step 3rd...

Страница 14: ...en released 7 4 Password Operation 1 Rotate EMS mushroom clockwise and pull out 2 Turn key clockwise to ON position 3 Press the pushbutton sequentially to enter password within 10 seconds Remark This...

Страница 15: ...rance 10 Sensitivity 110DBm Date Error Rate 10 3 Image Rejection 60dB Adjacent Channel Rejection 80dB 20kHz Output Relays 10A 250VAC 8A 30VDC Dimensions 6 57 x 6 06 x 3 46 167 x 154 x 88mm L x W x H W...

Страница 16: ...16 L10 SERIES RADIO CONTROL MANUAL PN 701L10005 1 5 9 0 Appendix 9 1 General Wiring Diagram for Radio Pendant Operation...

Страница 17: ...17 L10 SERIES RADIO CONTROL MANUAL PN 701L10005 1 5 Notes...

Страница 18: ...L10 SERIES RADIO CONTROL MANUAL PN 701L10005 1 5 Contact us for our Global Sales Offices www conductix us Conductix Wampfler 2017 Subject to Technical Modifications Without Prior Notice 18...

Отзывы: