25
Maintenance
Condair TE
6.6
Removing the Water Supply Strainer
Figure 9: Water supply strainer
To remove the water supply strainer (and clean the tubular mesh):
1. Remove the humidifier cover. Refer to chapter
2. Remove the drain cap from the drain pan, and remove the white connector of the water leakage
sensor. Refer to chapter
.
3. Remove the drain pan (and humidification module). Refer to chapter
4. Remove the water supply strainer cap. The tubular mesh can now be removed and cleaned.
•
Clean the tubular mesh with water.
5. Replace the equipment by following these instructions in reverse order.
6.7
Cleaning the Humidifier Filter
Figure 10:
Cleaning the humidifier air filter
Turn off the humidifier and remove power from the unit.
1. Open the humidifier cover then remove the filter from it.
2. Wash the filter with water. A neutral detergent may be used to clean the filter if necessary.
3. Dry the filter in a shaded location.
4. After it has dried, reattach the filter to the cover.
5. You may then restore power to the humidifier.
Water supply hose (with
built-in check valve)
Check valve
Water supply strainer
Strainer cap
O-ring
Gasket
Tubular mesh
Air outlet side
Filter
21.1 x 8.5 in (535 x 215 mm)