3.1 Unit description
$OOGHKXPLGL¿HUVRIWKHVHULHDUHKLJKSHUIRUPDQFHVXQLWVHVSHFLDOO\GHVLJQHGIRULQGXVWULDORUFRPPHUFLDOSXUSRVHVZKHUHKXPLGLW\OHYHO
should be controlled or water vapor condensation should be prevented. These units are particularly indicated for archives, ironing rooms,
bookstores, cheese factories, underground rooms, cellars and industrial sites where high humidity level is present. This series comprises
5 models which cover a capacity range from 50 to 200 l/24h. The units are designed for easy maintenance and service, each part being
readily accessible and, when required, easily replaceable thus reducing service and maintenance costs.
HBA units are designed for easy maintenance and service, each part being readily accessible and, when required, easily replaceable thus
reducing service and maintenance costs. The units are supplied with a solenoid valves set for the hot gas injection used to defrost the
evaporator in case of severe working conditions.
3.1.1 Frame
All units are made from hot-galvanised thick sheet metal, painted with polyurethane powder enamel at 180°C to ensure the best resistance
DJDLQVWWKHDWPRVSKHULFDJHQWVDQGWRRSHUDWHLQDJJUHVVLYHHQYLURQPHQWV7KHIUDPHLVVHOIVXSSRUWLQJZLWKUHPRYDEOHSDQHOV$39&GULS
tray is installed on all units. The colour of the unit is RAL 9010 both for the base and for the frontal panel.
5HIULJHUDQWFLUFXLW
The refrigerant circuit is made by using international primary brands components and according to ISO 97/23 concerning welding proce-
dures. The refrigerant gas used in these units is R410A. The refrigerant circuit includes: capillary tube, Schrader valves form maintenance
and control, pressure safety device (according to PED regulation). All the units are supplied with injection valves kit for hot gas defrost cycle.
3.1.3 Compressors
The compressors are rotative type, with thermal overload protection by a klixon embedded in the motor winding. The compressor is mount-
ed on rubber vibration dampers and it is supplied,standard, with sound-proof cover to reduce noise emission. The inspection is possible
through the frontal panel of the unit that allows the maintenance of the compressor.
3.1.4 Condenser and evaporator
&RQGHQVHUVDQGHYDSRUDWRUVDUHPDGHRIFRSSHUSLSHVDQGDOXPLQLXP¿QV
7KHGLDPHWHURIWKHFRSSHUSLSHVLV´DQGWKHWKLFNQHVVRIWKHDOXPLQLXP¿QVLVPP7KHWXEHVDUHPHFKDQLFDOO\H[SDQGHGLQWRWKH
DOXPLQLXP¿QVWRLPSURYHWKHKHDWH[FKDQJHIDFWRU7KHJHRPHWU\RIWKHVHKHDWH[FKDQJHUVJXDUDQWHHVDORZDLUVLGHSUHVVXUHGURSDQG
then the use of low rotation (and low noise emission) fans. All units are supplied, standard, with a powder coated steel drip tray and all
evaporators are supplied with a temperature sensor used as automatic defrost probe.
3.1.5 Fans
The fans are made of galvanized steel, centrifugal type. It is statically and dynamically balanced and supplied. The electric motors are
directly connected to the fan; they are all at 3 speeds, with integrated therma protection. The protection class of the motors is IP 54.
$LUÀOWHU
It
LVPDGHRIV\QWKHWLF¿OWHULQJPHGLDRQGXODWHGW\SHZLWKRXWHOHFWURVWDWLFFKDUJHWKH\DUHDOOUHPRYDEOHIRUGLIIHUHQWLDOGLVSRVDO(I¿FLHQF\
class G2, accordino to EN 779:2002.
2.6.3 Contact with eyes
,QJHVWLRQ
2.6.5 Further medical treatment
Rinse immediately using an eyewash or clean water, keeping eyelids open, for at least ten minutes. Seek medical assistance.
Do not induce vomiting. If the injured person is conscious, rinse his/her mouth with water and make him/her drink 200-300ml of water. Seek
immediate medical assistance.
Treat symptoms and carry out support therapy as indicated. Do not administer adrenaline or similar sympathomimetic drugs following
exposure, due to the risk of cardiac arrhythmia.
3. TECHNICAL CHARACTERISTICS
Содержание DC 100-R
Страница 48: ...Rev A 09 2017 48 DCIndustrial HKXPLGL HUV...
Страница 49: ...Rev A 09 2017 49 DC QGXVWULDO HKXPLGL HUV...
Страница 50: ...Rev A 09 2017 50 DCIndustrial HKXPLGL HUV...
Страница 51: ...Rev A 09 2017 51 DC QGXVWULDO HKXPLGL HUV...
Страница 52: ...RQGDLU URXS 7DOVWUDVVH 3IlI NRQ 6 3KRQH D LQIR FRQGDLU FRP ZZZ FRQGDLU FRP 2168 7 1 6 6 1 6 59 CH94 0002 00...