Door lifting spring strength
adjustment
Due to the material used for the cover
plate, the weight will differ accordingly.
You may set the spring strength using
screws (Fig. 20) on the front side so that
the door holds in the open position, and
close smoothly when lifted.
Connection of the discharge hose
Connect the discharge hose:
a) to a discharge pipe with a diameter of 40 mm with a hole,
b) or use the supplied adapter that enables discharge into a basin or a bathtub. Note: If you use the adapter, it must be
fixed properly. Otherwise, it can come loose and the water can spill on the floor.
c) Or use the siphon side hose of the sink or basin. Fix the hose to the lower side of the worktop. Thus, you will prevent
the water from flowing back into the dishwasher.
The end of the discharge hose should be 400 – 1,000 mm (Fig. 21) above the floor, not immersed in water to prevent
back flow.
Make sure the hose is not bent or jammed to prevent a reduced or stopped water supply.