6. Before installing the unit in the cut-out in the worktop, stick sealing against the leakage of liquids along the
perimeter of the bottom part of the glass-ceramic plate (enclosed depending on the type).
7. Position the unit onto the edge of the board and pass the power cord through the opening so that the plug or
terminals remain accessible after installation.
8. Push the unit carefully into place. Be careful not to squeeze the power cord. Fix it in the required position using
4 clamps (supplied).
9. Plug the supply cable in the wall outlet or the terminal box.
Removal
To uninstall the unit, it is important to proceed correctly:
1. First, unplug the power cord from the mains (pull out the plug or switch off the circuit breaker).
2. Remove the attachment screws.
3. Slide out the unit and at the same time pull out the power cord carefully.
Connecting to the mains
•
Only authorized personnel can install the connection!
• Make sure the mains voltage and current protection correspond to the values on the rating plate. Otherwise
the installed electric circuit could be overloaded, especially in the case of single-phase connection (230 V). We
recommend using a separately protected electric circuit.
•
Use solely electric power distribution with PE protective conductor.
• Do not use adapter plugs, connectors or extension cables. They could create a risk of fire due to overheating.
• The supply cable plug or the circuit breaker has to be freely accessible even after the installation of the unit.
• The electrical safety of the unit can only be guaranteed if the protective terminal of the unit is connected to the
protective conductor of the mains.
• The manufacturer bears no responsibility for damage caused to people or objects as a result of a missing or bad
protective connection.
• The power cord must be located so that it does not come into contact with hot parts of the unit and so that it is
not deformed and excessively bent.
Connection of the terminal box of the unit
WARNING!
Only authorized personnel can install the connection!
A switch or circuit breaker for disconnection of the unit from the mains must be installed in the wiring before the
unit, where the distance between open contacts of all poles is at least 3 mm.
The unit can be connected in the following two ways:
a) By a 3-core supply cable (230 V)
Use a cable with wires of a diameter of at least 4 mm, e.g. the H05V2V2-F3x4.0 type, and press endings on its ends to
prevent fraying. For the connection see Fig. 3.
b) By a 4-core or 5-core supply cable (400 V 2N)
Use e.g. a cable with wires of a diameter of at least 4 mm, e.g. the H05V2V2-F4x4.0 or H05V2V2-F5x4,0 type, and press
endings on its ends to prevent fraying. For the connection see Fig. 4.