4
O
p
e
ra
ti
o
n
S t o p p i n g t h e D r y e r
The DC-T Dryer control is programmed to follow a procedure for proper stopping the
dryer. Once the stop button has been pressed (or the Autostop time is reached), the heaters
will be turned off (RW hopper heaters, heater pack, or other hopper heater) and the dryer
blower will continue to run until the regen temperature reaches the factory set cooldown
setpoint.
To stop the dryer:
1
Press the stop button on the dryer control.
The hopper heaters
will turn off immediately and the blower will continue to run until
the dryer reaches the cooldown setpoint.
2
Observe the dryer status changing to “Stopping” or
“Shutdown”.
3
Wait until the dryer status changes to “Standby” which will
alert you that the cooldown setpoint has been reached.
Depending on your process temperature, this cooldown time could
only take a few seconds, or could take longer.
4
If you would like to shut down the dryer at this time, turn the
rotary disconnect switch to the OFF position.
ResinWorks configuration
Stand alone configuration
OFF
O
O
N
I
Standby
IMPORTANT:
Except in an emergency, aways wait until the dryer
control displays “Standby” in the status display before turning the
rotary disconnect to the OFF position. Failure to do so will not allow
the dryer to progress through the cooldown procedure and could
result in damage to your equipment.
125
-40
O p e r a t i o n l
4 - 8 5
Содержание Carousel Plus W Series
Страница 6: ...iv l Table of Contents...
Страница 20: ...2 8 l Description...
Страница 34: ...3 14 l Installation...
Страница 44: ...4 10 l Operation Control Function Flow Charts From the Alarm screen Home Alarms...
Страница 82: ...4 48 l Operation Control Function Flow Charts From the Alarm screen Home Alarms Alarm Banner Pop up...
Страница 114: ...4 80 l Operation...
Страница 115: ...4 O p e r a t i o n General Operation Stand Alone and ResinWorks Dryer Configuration Operation l 4 81...
Страница 130: ...4 96 l Operation...
Страница 184: ...B 3 l Appendix...