background image

Connect one side of an Ethernet cable into any switch port and connect the 

other side to your attached device.  Make sure that the cables are less than 

100 meters (328 feet).

• 

Uplink ports: 

         10BASE-T: 2-pair 

         Category 3, 4, 5 

         cable
• 

Uplink ports: 

         100BASE-TX: 

          2-pair Category 5

• 

Uplink ports: 

         1000BASE-TX: 

         4-pair Category 5 

         cable
• 

PoE ports: 4-pair 

         Category 5e / 6 

         cable

LEDs

This table provides information about the status LEDs.

LEDs

Status

Description

Power

Green

Valid DC input power applied

Off

No power

Alarm

Red

A power link failure has occurred

Off

No failure has occurred

RJ45 Pin 10/100BASE-TX PoE 

(Alternative B)

1000BASE-TX

1

RX+

BI_DA+

2

RX -

BI_DA-

3

TX +

BI_DB+

4

Vport+

BI_DC+

5

Vport+

BI_DC-

6

TX -

BI_DB-

7

Vport-

BI_DD+

8

Vport-

BI_DD-

5

Содержание ROCKETLINX ES7110

Страница 1: ...QUICK INSTALLATION GUIDE 2000550 Rev E Release Date August 2015 ROCKETLINX ES7110 ES7110 ES7110 VB ...

Страница 2: ...ides Gigabit bandwidth uplink for large image traffic but also supports QoS to adjust the priority of data transfer Using the Fault Relay the ES7110 can automatically warn the administrator if there are any failures The compact IP30 rigid aluminum case allows the ES7110 to be reliably operated in an extreme environment Refer to the Comtrol website for more information about specific ES7110 model f...

Страница 3: ...assis and earth ground using 12 24AWG wire to ensure that the ES7110 is not damaged by noise or electrical shock a Loosen the earth ground screw on the bottom of the ES7110 with a screw driver b Tighten the screw after the earth ground wire is connected 2 Relay PWR DC Power output Power Supply AC Power input 12 to 24AWG Wire Power Supply Requirements ES7110 48VDC 96W Min ES7110 VB 12 24VDC 96W Min...

Страница 4: ... DIP switch number mapping to the corresponding PoE and Gigabit ports as follows Port G2 Port G1 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 DIP 9 DIP 10 The port break alarm is limited to an auto negotiation 10 100 full duplex device 3 Maximum 1A 24VDC Alarm System Extra Power System Port Alarm Earth Ground ...

Страница 5: ...htly push the bottom of the DIN rail clip into the track 3 Verify that the DIN rail clip is tightly attached to the track CONNECT THE POE OR RJ45 UPLINK PORTS You can use the following information to connect Ethernet cables between the ES7110 ports and the network nodes Ports G1 and G2 are Gigabit Ethernet ports that support 10BASE T 100BASE TX and 1000BASE TX Ports 1 8 are Fast Ethernet 10 100BAS...

Страница 6: ...gory 5 Uplink ports 1000BASE TX 4 pair Category 5 cable PoE ports 4 pair Category 5e 6 cable LEDs This table provides information about the status LEDs LEDs Status Description Power Green Valid DC input power applied Off No power Alarm Red A power link failure has occurred Off No failure has occurred RJ45 Pin 10 100BASE TX PoE Alternative B 1000BASE TX 1 RX BI_DA 2 RX BI_DA 3 TX BI_DB 4 Vport BI_D...

Страница 7: ... Full Duplex Collision Yellow Full duplex mode connection Blinking Data collision Off The link is inactive or operating in half duplex mode G1 G2 Link Activity Green The port is connected Blinking Transmitting or receiving Off The port link is inactive G1 G2 Speed Yellow Full duplex mode connection Blinking 3 blinks per cycle 1000Mbps 2 blinks per cycle 100Mbps 1 blink per cycle 10Mbps Off The lin...

Страница 8: ...se one of the following methods to contact Comtrol Contact Method Web Address or Phone Number Support http www comtrol com support Downloads http downloads comtrol com html default htm Website http www comtrol com Phone 1 763 957 6000 7 ...

Отзывы: