![Comtech Xicom Technology XTD-750K Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/comtech-xicom-technology/xtd-750k/xtd-750k_operation-and-installation-manual_2648551107.webp)
MNC-0500-026
29 of 32
Revision G
Amplifier Communication and Protocol, Rabbit CPU
Simulate Front Panel Input
Command Byte:
‘V’
Function:
Simulates Digital Rack HPA fornt panel keypad/encoder input.
Any/all front panel input can be simulated using this command. Combining
this command with query ‘5’,
Current Screen
, grants remote access to all
digital HPA menus and functions. Since digital HPAs maintain a menu system
internally
even if they have no front panel interface
, these two messages
provide an excellent method for setting up digital outdoor amplifiers.
Standard Parameters
(for all digital amplifers):
A variable length sequence of characters, each simulating a single front-
panel action.
‘A’ HV On.
‘a’ HV ON without enable
‘B’ HV off.
‘b’ HV OFF without enable
‘C’ Fault Reset.
‘D’ Setup.
‘E’ Enable.
‘F’ Fault Reset
‘G’ Terse Status Display.
‘H’ Verbose Status Display.
‘i’ Turn encoder shaft one click to the left.
‘j’ Turn encoder shaft one click to the right.
‘k’ Turn encoder shaft ten clicks to the left.
‘l’ Turn encoder shaft ten clicks to the right.
‘W’ Soft key 1.
‘X’ Soft key 2.
‘Y’ Soft key 3.
‘Z’ Soft key 4.
Note:
If communicating with an amplifier via Xicom’s digital outdoor
controller, reference the alternate parameter list. Otherwise use the standard
parameter list.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.