Sum Fault Input
Refer to Figure 14. The Sum Fault input comes from the other amplifier.
The Sum Fault input provides a pull up resistor of 100K to + 13V for an
open collector input at J6-M. A logic HI is present when the other amplifier
faults.
Figure 14, Sum Fault Input
Sum Fault Output
Refer to Figure 15. The Sum Fault output is an open collector output at
J6-L. The output transistor will be off when this amplifier faults.
Figure 15, Sum Fault Output