Electrical Installation
The equipment is rated for operation over the range 100 - 240 volts AC. It has a maximum power
consumption of 140 Watts (when all inputs are supplying DC to LNBs), and draws a maximum of
1.5 Amps.
The installation and connection to the line supply must be made in compliance to local or national
wiring codes and regulations.
The CDD-562L/564 is shipped with a line inlet cable suitable for use in the country of operation.
If it is necessary to replace this cable, ensure the replacement has an equivalent specification.
Examples of acceptable ratings for the cable include HAR, BASEC and HOXXX-X.
Examples of acceptable connector ratings include VDE, NF-USE, UL, CSA, OVE, CEBEC,
NEMKO, DEMKO, BS1636A, BSI, SETI, IMQ, KEMA-KEUR and SEV.
Operating Environment
DO NOT OPERATE THE UNIT IN ANY OF THESE EXTREME OPERATING
CONDITIONS:
•
AMBIENT TEMPERATURES LESS THAN 0°C (32°F) OR MORE THAN 50°C
(122°F). (MAXIMUM STORAGE TEMPERATURE ALLOWED IS -25°C
(-13°F) TO 85°C (185°F)).
•
PRECIPITATION, CONDENSATION, OR HUMID ATMOSPHERES OF MORE
THAN 95% RELATIVE HUMIDITY.
•
UNPRESSURIZED ALTITUDES OF MORE THAN 2000 METRES (6561.7
FEET).
•
EXCESSIVE DUST.
•
FLAMMABLE GASES.
•
CORROSIVE OR EXPLOSIVE ATMOSPHERES.
European Union Radio Equipment and Telecommunications Terminal
Equipment (R&TTE) Directive (1999/5/EC) and EN 301 489-1
Independent testing verifies that the unit complies with the European Union R&TTE Directive, its
reference to EN 301 489-1 (
Electromagnetic compatibility and Radio spectrum Matters [ERM];
ElectroMagnetic Compatibility [EMC] standard for radio equipment and services, Part 1:
Common technical requirements)
, and the Declarations of Conformity for the applicable
directives, standards, and practices that follow:
European Union Electromagnetic Compatibility (EMC) Directive
(2004/108/EC)
•
EN 55022 Class B – Limits and Methods of Measurement of Radio Interference
Characteristics of Information Technology Equipment.
Содержание Vipersat CDD-562L
Страница 2: ......
Страница 4: ...ii This page is intentionally blank ...
Страница 24: ...CDD 562L 564 Demodulator with Optional IP Module Revision 2 Preface MN CDD564L IOM xxii Notes ...
Страница 40: ...CDD 562L 564 Demodulator with IP Module Revision 2 Introduction MN CDD564L IOM 1 16 Notes ...
Страница 46: ...CDD 562L 564 Demodulator with IP Module Revision 2 Installation and Startup MN CDD564L IOM 2 6 Notes ...
Страница 70: ...CDD 562L 564 Demodulator with IP Module Revision 2 IP Module Ethernet Interface MN CDD564L IOM 4 14 Notes ...
Страница 80: ...CDD 562L 564 Demodulator with IP Module Revision 2 Updating Firmware MN CDD564L IOM 5 10 Notes ...
Страница 160: ...CDD 562L 564 Demodulator with IP Module Revision 2 CDD 56X CLI and Telnet Operation MN CDD564L IOM 8 56 Notes ...
Страница 206: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix A MN CDD564L IOM A 6 Notes ...
Страница 216: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix C MN CDD564L IOM C 4 Notes ...
Страница 254: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...