8.1.1 Interface Access
1. The demodulator does not allow concurrent access to the menu via Telnet
and the Console port. If the user connects via Telnet, the demodulator
automatically disables the Console port for the duration of the Telnet
session.
All Telnet-based menu pages allow a Telnet Logout to end a Telnet session.
Additionally, the demodulator automatically ends a Telnet session after a
preconfigured period of inactivity (definable from 1 to 60 minutes).
2. Any changes made to the demodulator IP parameters will be lost if the
demodulator is reset or loses power, unless the changes are first saved to
permanent storage. This applies to all of the IP parameters. Type ‘S’ from
any CLI/Telnet Menu page to save the actively set parameters.
3. All demodulator parameters configured via the CLI or Ethernet interface will
be automatically stored in the demodulator unit non-volatile RAM and will be
retained if there is a power loss.
For connection via a Terminal Emulator
: The user PC should be physically attached to the
Console port of the CDD-56X. The terminal emulator should be configured to match the Console
port setting. The default Console port setting is
38,400 bps
,
8 data bits
,
no parity
,
1 stop bit
and
no flow control
.
For connection via Telnet:
The user PC must have network connectivity to the 10/100 Ethernet
port of the CDD-56X. This connectivity can be over a local LAN, a remote LAN, or by satellite
link from another IP modem. The Ethernet Speed Mode is a configurable parameter of the
demodulator and, accordingly, its exact setting can vary between specific installations.
The CLI and Telnet User Access Levels are defined as follows:
User Interface
User Login Access Level
Admin User
Read/Write User
Read Only User
CLI
(direct to Console port)
Full Access – no Login
Full Access – no Login
Full Access – no Login
Telnet
Full Access, all Menus
No Access to Admin Menu
No Access
Full Access all other Menus
The factory defaults for user names/passwords are as follows:
Admin comtech/comtech
Read/Write opcenter/1234
Read Only monitor/1234
Содержание Vipersat CDD-562L
Страница 2: ......
Страница 4: ...ii This page is intentionally blank ...
Страница 24: ...CDD 562L 564 Demodulator with Optional IP Module Revision 2 Preface MN CDD564L IOM xxii Notes ...
Страница 40: ...CDD 562L 564 Demodulator with IP Module Revision 2 Introduction MN CDD564L IOM 1 16 Notes ...
Страница 46: ...CDD 562L 564 Demodulator with IP Module Revision 2 Installation and Startup MN CDD564L IOM 2 6 Notes ...
Страница 70: ...CDD 562L 564 Demodulator with IP Module Revision 2 IP Module Ethernet Interface MN CDD564L IOM 4 14 Notes ...
Страница 80: ...CDD 562L 564 Demodulator with IP Module Revision 2 Updating Firmware MN CDD564L IOM 5 10 Notes ...
Страница 160: ...CDD 562L 564 Demodulator with IP Module Revision 2 CDD 56X CLI and Telnet Operation MN CDD564L IOM 8 56 Notes ...
Страница 206: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix A MN CDD564L IOM A 6 Notes ...
Страница 216: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix C MN CDD564L IOM C 4 Notes ...
Страница 254: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...