ODU Operation
RAP-100 Remote Access Panel
3–4
Rev.
1
3.2.8 (ODU,ENABLE,1:1,RED
BOX)
SWITCHES
WAVEGUIDE SWITCH STATUS:
TX=OK RX=OK
This menu item provides the status of both the Tx and Rx Waveguide transfer switches.
If either switch is reporting an ambiguity from the commanded position the “OK” will
change to “FT”. This indicates a switch fault.
3.2.9 (ODU,ENABLE,1:1,RED
BOX)
VOLTAGES
REDUNDANCY BOX VOLTAGES:
5V= X.X 12V=XX.X
This menu item provides monitor of the voltages inside the Redundancy Controller Box.
This is provided to assist in trouble-shooting system problems.
3.2.10 (ODU,ENABLE,1:1,CSAT#1)
Selections
(ODU,ENABLE,1:1,CSAT#2)
Selections
(ODU,ENABLE,STAND-ALONE)
Selections
ODU SELECT: CONFIG INFO
MONITOR ALARMS (ENTER)
The user is prompted from 1 of 4 sub-menu branches using the LEFT/RIGHT arrow
keys, then press ENTER.
3.2.11 (ODU,ENABLE,1:1,CSAT#1)
CONFIG
(Confiuration)
(ODU,ENABLE,1:1,CSAT#2)
CONFIG (Confiuration)
(ODU,ENABLE,STAND-ALONE)
CONFIG (Confiuration)
ODU CONFIG: TRANSMITTER
RECEIVER MISCELLANEOUS
The user uses this menu item to select either the ‘Transmitter configuration branch”,
“Receiver configuration branch” or “Miscellaneous configuration branch”. Use the
LEFT/RIGHT arrow keys, then press ENTER.
3.2.12 (ODU,ENABLE,1:1,CSAT#1,CONFIG)
TRANSMITTER
(ODU,ENABLE,1:1,CSAT#2,CONFIG)
TRANSMITTER
(ODU,ENABLE,STAND-ALONE,CONFIG)
TRANSMITTER
ODU TX: FREQUENCY ATTEN
AMPLIFIER MUTE SLOPE
This menu item is used to select which ODU Transmitter parameter is to be modified.
Use the LEFT/RIGHT arrow keys, then press ENTER.