ODU Operation 

RAP-100 Remote Access Panel 

3–2  

Rev. 

3.2 MENU 

TREES 

3.2.1 SELECT 

 

SELECT: CONFIG TEST INFO 
MONIT  STORE/LD UTIL ODU 

 
The user is presented with the following choices: 
 

CONFIG 

(Configuration) This menu branch permits the user to fully configure the unit. 

TEST 

This menu branch permits the user invoke one of several test modes (loopbacks, for example). 

INFO 

(Information) This menu branch permits the user to view information on the unit, without 
having to go into configuration screens. 

MONIT 

(Monitor) This menu branch permits the user to monitor the alarm status of the unit, to view 
the log of stored events, and to display the Receive Parameters screen. 

STORE/LD 

(Store/Load) This menu branch permits the user to store and to retrieve up to 10 different 
modem configurations. 

UTIL 

(Utility) This menu branch permits the user to perform miscellaneous functions, such as 
setting the Real-time clock, adjusting the display brightness, etc. 

ODU 

(Outdoor Unit) This permits the user to monitor and control a Comtech EFData RF 
Transceiver, if connected. 

 
The first six items are covered in the existing modem manuals.  The ODU item is now 
described in detail. 

3.2.2 ODU 

 TRANSCEIVER CONTROL:      

 DISABLE  ENABLE  (ENTER) 

 
DISABLE 

This menu item turns OFF the FSK link to the ODU. 

 
ENABLE 

This menu item turns ON the FSK link to the ODU. 

3.2.3 (ODU,ENABLE) 

System 

Type 

 SELECT ODU SYSTEM TYPE:  

 STAND-ALONE      1:1 

  
The STAND-ALONE items should be selected when the Modem is linked via the Rx IF 
cable to a single Comtech EFData ODU.  The 1:1 items should be selected when the 
Modem is linked to a redundant ODU system via connection between the Rx IF and the 
ODU Redudnancy Controller Box. 

Содержание RAP-100

Страница 1: ...Part Number MN RAP100 IOM Revision 1 RAP 100 Remote Access Panel Installation and Operation Manual...

Страница 2: ...the USA Comtech EFData 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161 RAP 100 Remote Access Panel Installation and Operation Manual Part Number MN RAP100 IOM Revision 1 Dec...

Страница 3: ...tion Update RAP 100 Remote Access Panel Installation and Operation Manual MN RAP100 IOM REV 1 Original Manual Part Number Rev MN RAP100 IOM Rev 1 Errata Number PLM Document ID ER RAP100 EA1 PLM CO Num...

Страница 4: ...ER RAP100 EA1 Revision This document is not subject to revision update PLM CO C 0029408 Page 2 of 2...

Страница 5: ...port Department at service comtechefdata com Contact us via the web at www comtechefdata com 1 To return a Comtech EFData product in warranty and out of warranty for repair or replacement 2 Request a...

Страница 6: ...ranty viii Exclusive Remedies viii Disclaimer viii CHAPTER 1 INTRODUCTION 1 1 1 1 Equipment Use 1 1 1 2 Equipment Power 1 1 1 3 CSAT Interface 1 1 1 4 Getting Started 1 2 CHAPTER 2 REDUNDANT CSAT CONT...

Страница 7: ...T 1 CONFIG TRANSMITTER MUTE ODU ENABLE 1 1 CSAT 2 CONFIG TRANSMITTER MUTE ODU ENABLE STAND ALONE CONFIG TRANSMITTER MUTE 3 5 3 2 17 ODU ENABLE 1 1 CSAT 1 CONFIG TRANSMITTER SLOPE ODU ENABLE 1 1 CSAT 2...

Страница 8: ...ANEOUS REF ADJUST ODU ENABLE STAND ALONE CONFIG MISCELLANEOUS REF ADJUST 3 10 3 2 35 ODU ENABLE 1 1 CSAT 1 CONFIG MISCELLANEOUS RTC ODU ENABLE 1 1 CSAT 2 CONFIG MISCELLANEOUS RTC ODU ENABLE STAND ALON...

Страница 9: ...TAND ALONE ALARMS CURRENT 3 13 3 2 50 ODU ENABLE 1 1 CSAT 1 ALARMS STORED ODU ENABLE 1 1 CSAT 2 ALARMS STORED ODU ENABLE STAND ALONE ALARMS STORED 3 13 3 2 51 ODU ENABLE 1 1 CSAT 1 ALARMS STORED VIEW...

Страница 10: ...es or risks of property damage WARNING WARNING indicates a potentially hazardous situation that if not avoided could result in death or serious injury Metric Conversion Metric conversion information i...

Страница 11: ...other warranty is expressed or implied Comtech EFData specifically disclaims the implied warranties of merchantability and fitness for particular purpose Exclusive Remedies The remedies provided here...

Страница 12: ...nication equipment racks 1 2 Equipment Power The equipment is rated for operation over the range 100 240 volts AC It has a maximum power consumption of 15 watts 1 3 CSAT Interface The RAP 100 is desig...

Страница 13: ...ED when a problem exists If the LED is RED go to the LINK menu and select ESTABLISH Select the when queried RE ESTABLISH COMM LINK The RAP 100 will now attempt to communicate to the CSAT via the globa...

Страница 14: ...AT system with a RAP 100 used as the system monitor and control device RS485Tx RS485Tx RS485 Rx RS485 Rx RS485Tx RS485Tx RS485 Rx RS485 Rx RS485Tx RS485Tx RS485 Rx RS485 Rx Micro Controller A AUXCOM T...

Страница 15: ...a change in the switch position via either a serial command to the Redundancy Controller Box or by shorting the appropriate pins on the interface connector Again this assumes that both unit are non fa...

Страница 16: ...This will take you to the REDUNDNANCY BOX menu selection There are four 4 sub windows in this menu branch ONLINE MODE SWITCHES and VOLTAGES The paragraphs below explain each of these sub windows in de...

Страница 17: ...change the position of the Tx and Rx transfer switches thus controlling the ONLINE OFFLINE status of the two CSATs If the cursor is on CSAT 1 then CSAT 1 is ONLINE and CSAT 2 is OFFLINE IF the cursor...

Страница 18: ...hen it is displayed LEFT ARROW Moves the cursor to the left when it is displayed UP ARROW Used for editing the value at the current cursor position if appropriate If this is a numeric field this will...

Страница 19: ...to retrieve up to 10 different modem configurations UTIL Utility This menu branch permits the user to perform miscellaneous functions such as setting the Real time clock adjusting the display brightne...

Страница 20: ...of 4 items 3 2 6 ODU ENABLE 1 1 RED BOX ONLINE ONLINE UNIT CSAT 1 CSAT 2 The cursor will be flashing under either CSAT 1 or CSAT 2 This is the indication of the currently ONLINE unit If the user desi...

Страница 21: ...TAND ALONE Selections ODU SELECT CONFIG INFO MONITOR ALARMS ENTER The user is prompted from 1 of 4 sub menu branches using the LEFT RIGHT arrow keys then press ENTER 3 2 11 ODU ENABLE 1 1 CSAT 1 CONFI...

Страница 22: ...T ODU TX ATTENUATION 15 00 dB PRESS ENTER The user is prompted to edit the transmit attentuation This is accomplished by selecting the digit to be edited using the LEFT RIGHT arrow keys The value of t...

Страница 23: ...transmit slope setting This is accomplished using the UP DOWN arrow keys The user then presses ENTER 3 2 19 ODU ENABLE 1 1 CSAT 1 CONFIG RECEIVER ODU ENABLE 1 1 CSAT 2 CONFIG RECEIVER ODU ENABLE STAN...

Страница 24: ...LONE CONFIG RECEIVER MUTE SELECT RX MUTE STATE MUTED UNMUTED ENTER The user is prompted to select either MUTED or UNMUTED using the LEFT RIGHT arrow keys then to press ENTER 3 2 23 ODU ENABLE 1 1 CSAT...

Страница 25: ...ble 3 2 27 ODU ENABLE 1 1 CSAT 1 CONFIG RECEIVER LNA CAL Calibrate ODU ENABLE 1 1 CSAT 2 CONFIG RECEIVER LNA CAL Calibrate ODU ENABLE STAND ALONE CONFIG RECEIVER LNA CAL Calibrate CALIBRATE LNA CURREN...

Страница 26: ...EOUS ODU ENABLE STAND ALONE CONFIG MISCELLANEOUS MISC COLD START AFR XREF REF ADJUST RTC This menu item is used to select miscellaneous ODU parameter for modification Use the LEFT RIGHT arrow keys the...

Страница 27: ...The user is prompted to edit the Internal 10MHz Reference setting using the UP Down arrow keys then to press ENTER The value will scroll between 000 and 255 NOTE The Internal Refernece is adjusted in...

Страница 28: ...ope adjustment press ENTER 3 2 39 ODU ENABLE 1 1 CSAT 1 INFO RECEIVER ODU ENABLE 1 1 CSAT 2 INFO RECEIVER ODU ENABLE STAND ALONE INFO RECEIVER Rx ON 3625 0 10 00 MUTE OFF 0 0 This window provides the...

Страница 29: ...3 2 44 ODU ENABLE 1 1 CSAT 1 MONITOR RX Receiver ODU ENABLE 1 1 CSAT 2 MONITOR RX Receiver ODU ENABLE STAND ALONE MONITOR RX Receiver RX SYNTH TUNE 03 1 IFLO 10 9 TEMP 28C This window provides the Rx...

Страница 30: ...rms Log Use the LEFT RIGHT arrow keys then press ENTER 3 2 49 ODU ENABLE 1 1 CSAT 1 ALARMS CURRENT ODU ENABLE 1 1 CSAT 2 ALARMS CURRENT ODU ENABLE STAND ALONE ALARMS CURRENT TX OK RX OK PWR SUP OK MIS...

Страница 31: ...UP DWN The operator uses the UP DOWN arrow keys to sequentially view the individual entries in the Stored Events Log then press CLEAR to exit the window 3 2 52 ODU ENABLE 1 1 CSAT 1 ALARMS STORED CLEA...

Страница 32: ...103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoir Pound Troy Kilogram 1 gram 0 03527 0 03215 0 002205 0 0...

Страница 33: ......

Страница 34: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...