RRS11 Solid-State Transfer Switch 

Operation 

MN-RRS11 

3–4 

Rev. 3 

Table 3-1A, RRS11-L L-Band Rear Panel Connectors 

Connector 

ID 

Nomenclature 

Description 

J1 

Online Status 

Output 

9-Pin D-Sub Switch Status Form-C Relay Outputs 

J2 

Prime Mod Control 

9-Pin D-Sub Control Connector From Prime Modulator 

J3 

Backup Mod Control 

9-Pin D-Sub Control Connector From Backup Modulator 

J4 

Monitor A Input 

SMA 50 Ohm from Modulator A Monitor Output 

J5 

Monitor B Input 

SMA 50 Ohm from Modulator B Monitor Output 

J6 

On-Line Output 

N-Type 50 Ohm, Output of On-Line Modulator to Uplink Chain. 

J7 

Off-Line Output 

N-Type 50 Ohm Output of Monitor Port of Off-Line 

Modulator 

J8 

L-Band Input A 

SMA 50 Ohm From Modulator A 

J9 

L-Band Input B 

SMA 50 Ohm From Modulator B 

 
 
 
Each modulator has a 9-Pin D-Sub Connector that connects to the RRS11 switch.  A 1:1 cable is 
connected from each modulator to the RRS11 switch.  The pinout for the control connector is 
listed in Table 3-2.  
 

Table 3-2.  Switch Prime/Backup Control Pinout 

Pin No. 

Signal Name 

Direction 

Description 

Signal Ground 

Input 

Modulator GND 

Backup Select 

Output 

One modulator is designated as Backup.  This line 

is tied low on the Backup Mod Control connector. 

+DC 

Input 

+12V DC Power 

nPrime_Sel 

Input 

Forces On-Line Output to Prime 

nBackup_Sel 

Input 

Forces On-Line Output to Backup 

Fault-In 

Input 

Fault Output From Modulator 

Fault-Out 

Output 

Connects to Fault-In Monitor on Modulator 

Switch-State 

Output 

Switch State Monitor.                                       

Logic '1' = Prime Online 

NC 

--- 

--- 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание RADYNE RRS11

Страница 1: ...contained in this document supersedes all previously published information regarding this product This manual is subject to change without prior notice RRS11 Solid State Transfer Switch Installation...

Страница 2: ...Copyright 2010 Comtech EF Data All rights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161...

Страница 3: ...r Switch Backup Operation 3 3 CHAPTER 4 MAINTENANCE AND TROUBLESHOOTING 4 1 4 1 Basic Troubleshooting and Maintenance 4 1 4 2 Basic User Checks 4 1 4 2 1 Checking the Cabling and Connectors 4 1 CHAPTE...

Страница 4: ...Table of Contents MN RRS11 RRS11 Solid State Transfer Switch Rev 3 iv Notes...

Страница 5: ...estions Concerning this Manual Comments and suggestions regarding the content and design of this manual are appreciated To submit comments please contact the Comtech EF Data Technical Publications dep...

Страница 6: ...dicates a statement associated with the task being performed or information critical for proper equipment function CAUTION CAUTION indicates a hazardous situation that if not avoided may result in min...

Страница 7: ...ation as defined in EN60950 Low Voltage Directive LVD The following information is applicable for the European Low Voltage Directive EN60950 HAR Type of power cord required for use in the European Com...

Страница 8: ...ech EF Data Corporation s obligations under this warranty are limited to repair or replacement of failed parts and the return shipment to the buyer of the repaired or replaced parts Limitations of War...

Страница 9: ...tated is in lieu of all other warranties expressed implied or statutory including those of merchantability and fitness for a particular purpose The buyer shall pass on to any purchaser lessee or other...

Страница 10: ...ber serial number and a description of the problem Request a Return Material Authorization RMA number from the Comtech EF Data Customer Support representative Pack the product in its original shipping...

Страница 11: ...an be configured to support 70 140 MHz or L Band System An external power source is not required DC power and fault status is supplied to by each DM240XR The RRS11 will trigger a switchover in the eve...

Страница 12: ...RRS11 Solid State Transfer Switch Introduction MN RRS11 1 2 Rev 3 Notes...

Страница 13: ...lators The supplied cables lengths only allow for this configuration There are no user serviceable parts or configuration settings located inside any Solid State Transfer Switch Chassis There is a pot...

Страница 14: ...Unit RRS11 Test Data Sheet Interconnect Cables IF Monitor and Control Installation and Operation Manual 2 2 1 Test Data Sheet Each RRS11 Solid State Transfer Switch is shipped with a Test Data Sheet T...

Страница 15: ...etup and configuration perform the following procedure 1 Interconnect the units as shown in the figures below 2 Proceed to Section 3 User Interface for information on the Solid State Transfer Switch c...

Страница 16: ...Cable Connections between RRS11 and two DM240XR Units Table 2 2 70 140 MHz Interconnect Cable Part Numbers Cable Quantity Description Part Number A 2 Control Cable DB 9 Straight Cable CA 3677 1 B 2 I...

Страница 17: ...MN RRS11 3 1 Rev 3 Chapter 3 Operation 3 1 Solid State Transfer Switch Operation A functional block diagram of the RRS11 RRS11 L signal flow is illustrated in Figure 3 1 below...

Страница 18: ...RRS11 Solid State Transfer Switch Operation MN RRS11 3 2 Rev 3 Figure 3 1 RRS11 Functional Block Diagram...

Страница 19: ...ll automatically cause the switch to place the backup on line The switch is non revertive That is once a switch occurs it requires a manual command either through the M C or from the front panel to re...

Страница 20: ...tor J8 L Band Input A SMA 50 Ohm From Modulator A J9 L Band Input B SMA 50 Ohm From Modulator B Each modulator has a 9 Pin D Sub Connector that connects to the RRS11 switch A 1 1 cable is connected fr...

Страница 21: ...Table 3 3 Table 3 3 Switch Online Statue Pinout Pin No Signal Name Description 4 Signal Ground Switch GND 1 Relay 1 NO Relay Normally Open Contact Closed When the Backup Modulator is On Line 3 Relay 1...

Страница 22: ...RRS11 Solid State Transfer Switch Operation MN RRS11 3 6 Rev 3 Notes...

Страница 23: ...er Service Department at 602 437 9620 for further information and instructions 4 2 Basic User Checks Upon the detection of an operational failure the source of the failure must be determined Basic use...

Страница 24: ...RRS11 Solid State Transfer Switch Maintenance and Troubleshooting MN RRS11 4 2 Rev 3 Notes...

Страница 25: ...ion DM240 PIIC OR DM240XR only Switch Time 50 msec Maximum Rear Panel Ports L Band input J7 SMA 50 ohm mod A L Band input J8 SMA 50 ohm mod B L Band output J6 N type 50 ohm online L Band output J9 N t...

Страница 26: ...z Configuration DM240 PIIC OR DM240XR only Switch Time 50 msec Maximum Rear Panel Ports IF input J7 BNC F 75 ohm mod A IF input J8 BNC F 75 ohm mod B IF output J6 BNC F 75 ohm online IF output J9 BNC...

Страница 27: ...3 1 760 x 103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoirdupois Pound Troy Kilogram 1 gram 0 03527 0 032...

Страница 28: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...

Отзывы: