Chapter 2. Installation
This section provides unpacking and installation instructions, and a description of external
connections, status and contact closure alarm information.
2.1
Installation Requirements
The RRS11 Solid-State Transfer Switches is a standard one rack unit (1RU) high (1.75
inches/4.45 cm) vertically, 19 inches (48.3 cm) wide, and 17 inches (43.2 cm) deep. The RRS11
Switch is installed between two DM240-PIIC or DM240XR modulators. The supplied cables
lengths only allow for this configuration.
There are no user-serviceable parts or configuration settings located
inside any Solid-State Transfer Switch Chassis. There is a potential
shock hazard internally at the power supply module. DO NOT open the
Solid-State Transfer Switch Chassis under any circumstances.
Before initially applying power to the unit, it is a good idea to disconnect
the transmit output from the operating ground station equipment. This is
especially true if the current Solid-State Transfer Switch configuration
settings are unknown, where incorrect settings could disrupt existing
communications traffic.
Содержание RADYNE RRS11
Страница 4: ...Table of Contents MN RRS11 RRS11 Solid State Transfer Switch Rev 3 iv Notes...
Страница 12: ...RRS11 Solid State Transfer Switch Introduction MN RRS11 1 2 Rev 3 Notes...
Страница 18: ...RRS11 Solid State Transfer Switch Operation MN RRS11 3 2 Rev 3 Figure 3 1 RRS11 Functional Block Diagram...
Страница 22: ...RRS11 Solid State Transfer Switch Operation MN RRS11 3 6 Rev 3 Notes...
Страница 24: ...RRS11 Solid State Transfer Switch Maintenance and Troubleshooting MN RRS11 4 2 Rev 3 Notes...
Страница 28: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...