CRS-180 70/140 MHz IF 1:1 Redundancy Switch
MN/CRS180.IOM
Modem and Switch Configuration
Revision 11
4–12
4.4.2 IP Redundancy Configuration
Before continuing you must remember that, when you use the Command Line
Interface (CLI), you can make configuration changes to the Online modem only.
Make sure to press ‘S’ to “Save Parameters to permanent storage” after making any
changes to an active CLI page. This ensures that the configuration change is also
applied to the Backup modem.
Do these steps for setup of a CDM-570/A 1:1 IP Redundancy System:
Step
Task
1
Use a Layer 2 switch (preferred) or hub to establish an Ethernet connection between the two modems.
2
Before you connect the modems to the CRS-180, you must first use the modem CLI to configure the
following CDM-570LAL IP operation settings:
•
Disable 1:1 Redundancy operation – From the
Main Menu
, press ‘
E
’ to open the
1:1 Redundancy
Configuration
page.
o
Press ‘
R
’ to toggle 1:1 Redundancy as
[Disabled].
•
From the
Main Menu
, press ‘
A
’ to open the
Administration
page.
o
Press ‘
W
’ (
Administration
Working Mode
) and set both modems to the same Working
Mode.
o
Press ‘
F
’ (
Administration
Feature Configuration
) and make sure to configure, using all
applicable submenus, both modems to have the same IP-related operability and settings.
3
For each modem, use the CLI to enter a unique IP Address that is on the same subnet:
•
From the Main Menu, press ‘
I
’ to open the
Interface Configuration
page.
•
Press ‘
E
’ to open the
Ethernet Interface
page (
Interface Configuration
Ethernet Interface
):
•
Press ‘
I
’ to enter the IP Address.
4
Verify that you can ping from one modem to the other:
•
From the Main Menu, press ‘
O
’ to open the
Operations and Maintenance
page.
•
Press ‘
G
’ to open the
Diagnostics
page (
Operations and Maintenance
Diagnostics
):
•
Press ‘
P
’ and then enter the IP Address of the other modem in the redundant pair.
5
Re-enable 1:1 Redundancy operation – From the
Main Menu
, press ‘
E
’ to open the
1:1 Redundancy
Configuration
page.
•
Press ‘
R
’ to toggle 1:1 Redundancy as
[Enabled]
.
6
Power down both modems.
7
Connect the modems to the CRS-180.
CDM-570/CDM-570L/CDMR-570L Satellite Modem Installation and Operation
Manual (CEFD P/N MN/CDM570L.IOM): Sect. H.6 Cabling with the CDM-570L.
Содержание CRS-180
Страница 10: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Table of Contents Revision 11 x BLANK PAGE ...
Страница 18: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Preface Revision 11 xviii Notes ...
Страница 46: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Modem and Switch Configuration Revision 11 4 6 Notes ...
Страница 48: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Modem and Switch Configuration Revision 11 4 8 Notes ...
Страница 82: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Cables and Connections Revision 11 5 24 Notes ...
Страница 90: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Cables and Connections Revision 11 5 32 Notes ...
Страница 110: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Cables and Connections Revision 11 5 52 Notes ...
Страница 133: ......
Страница 134: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...