background image

CDM-710G High-Speed Satellite Modem      

Revision 1 

HSSI Interface (CDI-60) 

MN-CDM710G 

13–2 

13.2 

Physical Description 

Figure 13-2

 depicts the block diagram for the interface. The HSSI data interface is implemented 

on a 3.95 x 7.022 inch (10.03 x 17.83 cm)  PCB. Connection to the modem is provided when the 
96-pin DIN connector is engaged into the modem slot.   

 

Figure 13-2.   CDI-60 HSSI Data Interface Module Block Diagram 

Figure 13-3 

shows the CDI-60 HSSI interface, looking towards the real panel. The 50-pin 

SCSI-2 connector serves as the data port, and a Light-Emitting Diode (LED), labeled 

Activity

, is 

lit green when the interface is enabled. 

The CDI-60 HSSI interface provides: 

 

A single HSSI interface; 

 

DCE Connection; 

 

ST clock is sourced to the terrestrial interface for use as reference by DTE; 

 

TT is treated as an incoming External Clock, and the interface phase locks to it; 

 

TA / CA is supported. 

The connector pinout for the interface is provided in 

Sect. 13-3; a

 summary of specifications for the 

interface is provided in 

Sect. 13-4

.  

 

Processor

Mux /

Demux

PLL

Rx 

Buffer

Interface

Loopback

Control

Processor

Mux /

Demux

PLL

Rx 

Buffer

Interface

Loopback

Control

Modem
Interface

Clk

&

Data

μ

C

HSSI Interface

TT

SD

ST

Common

J1

Rx Clock

Rx Data

50 Pi

H

S

S

I Fem

al

e

TA

CA

(RTS)

(CTS)

Tx Clock Input (External)

Tx Data

Output Clock (Rate Programmable)

RT

RD

Содержание CDM-710G

Страница 1: ...ent supersedes all previously published information regarding this product Product specifications are subject to change without prior notice CDM 710G High Speed Satellite Modem Installation and Operat...

Страница 2: ......

Страница 3: ...Appendix A REMOTE CONTROL Original Manual Part Number Rev MN CDM710G Rev 1 Errata Number PLM Document ID ER CDM710G EA1 PLM CO Number C 0025029 Comments The updated information will be incorporated in...

Страница 4: ...Errata A for MN CDM710G Rev 1 Update FLT Serial Remote Control Query ER CDM710G EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION UPDATE PLM CO C 0025029 Page 2 of 4 This page is intentionally blank...

Страница 5: ...pply fault 5 0 Volts Framer Card 7 Power supply fault 12 0 Volts Framer Card 8 Power supply fault 12 0 Volts Framer Card 9 Power supply fauilt 18 0 Volts Framer Card A FLASH Checksum B FEC1 Load C FEC...

Страница 6: ...00 PPM C GBEI Card Data rate 200 PPM D GBEI No PHY Link E Encoder FIFO Empty F Encoder FIFO Full G SERDES Parity Errors H Reserved I Tx Ais Interface 1 J Tx Ais Interface 2 K Tx Cable Interface 1 L Tx...

Страница 7: ...Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161 CDM 710G High Speed Satellite Modem Installation and Operation Manual Includes data for the CDM 710G 70 140 MHz and CDM...

Страница 8: ...This page is intentionally blank...

Страница 9: ...ons Terminal Equipment Directive xv CE Mark xv RoHS Compliancy xv EMC Electromagnetic Compatibility xv Warranty Policy xvii Customer Support xix Online Customer Support xix CHAPTER 1 INTRODUCTION 1 1...

Страница 10: ...lator 1 16 1 5 3 Demodulator 1 16 1 5 3 1 CDM 710G 70 140 MHz Demodulator 1 16 1 5 3 2 CDM 710GL L Band Demodulator 1 17 1 5 4 Test Functions 1 19 1 5 5 Monitor Functions 1 19 1 5 6 Remote Port Operat...

Страница 11: ...rms Connector DB 15M 4 4 4 4 2 P2 Remote Port Connector RS 232 485 DB 9M 4 5 4 4 3 J7 External Reference Input 4 5 CHAPTER 5 FLASH UPGRADING 5 1 5 1 Flash Updating via Internet 5 1 5 2 Base Modem Ethe...

Страница 12: ...t Ethernet Rx 6 31 CONFIG Intfc2 Gigabit Ethernet Man 6 31 CONFIG Intfc2 Gigabit Ethernet Stats 6 32 CONFIG Intfc2 Gigabit Ethernet SWOP SWitch OPeration 6 34 6 3 1 7 CONFIG Ref 6 35 6 3 1 8 CONFIG Au...

Страница 13: ...7 1 7 2 User Login 7 2 7 2 1 Web Server Menu Tree 7 3 7 3 Web Server Page Descriptions 7 4 7 3 1 Home Page 7 4 7 3 1 1 Home Home Page 7 4 7 3 1 2 Home Contact Page 7 5 7 3 1 3 Home Support Page 7 6 7...

Страница 14: ...CDI 60 HSSI Interface Transmit Clocking 10 4 10 3 2 CDI 60 HSSI Interface Receive Clocking 10 4 10 4 CDI 70 10 100 1000 Base T Gigabit Ethernet GigE Interface 10 5 CHAPTER 11 FORWARD ERROR CORRECTION...

Страница 15: ...GigE Interface 14 6 14 6 GigE Operational Setups 14 9 APPENDIX A REMOTE CONTROL A 1 A 1 Overview A 1 A 2 RS 485 A 1 A 3 RS 232 A 2 A 4 Basic Protocol A 2 A 5 Packet Structure A 2 A 5 1 Start Of Packe...

Страница 16: ...ame 188 Byte Format 1 20 Table 1 6 Data Rate Range Short FECFrame 188 Byte Format 1 21 Table 4 1 CDM 710G Rear Panel Connectors Reference 4 2 Table 6 1 Symbol Rate Data Rate Range Standard FECFrame an...

Страница 17: ...or Point to Multipoint with Routers 3 11 Figure 3 12 Wired around for Point to Multipoint with Routers 3 11 Figure 3 13 Point to Multipoint using Switches 3 12 Figure 3 14 Wired thru Hub to Remotes Sp...

Страница 18: ...3 CDI 10 1 Rear Panel View 12 2 Figure 13 1 CDI 60 HSSI Data Interface Module 13 1 Figure 13 2 CDI 60 HSSI Data Interface Module Block Diagram 13 2 Figure 13 3 CDI 60 HSSI Data Interface Module Rear P...

Страница 19: ...ata com Metric Conversion Metric conversion information is located on the inside back cover of this manual This information is provided to assist the operator in cross referencing non metric to metric...

Страница 20: ...is exposed to extremes of temperature outside the ambient range 0 to 50 C 32 to 122 F precipitation condensation or humid atmospheres above 95 RH altitudes unpressurized greater than 2000 meters exces...

Страница 21: ...iancy This unit satisfies with exemptions the requirements specified in the European Union Directive on the Restriction of Hazardous Substances Directive 2002 95 EC EU RoHS EMC Electromagnetic Compati...

Страница 22: ...the following instructions Connections to the transmit and receive IF ports N type female connectors should be made using a good quality coaxial cable for example RG213 U All D type connectors attach...

Страница 23: ...the repaired or replaced parts Limitations of Warranty The warranty does not apply to any part of a product that has been installed altered repaired or misused in any way that in the opinion of Comte...

Страница 24: ...Corporation s products the aforementioned warranty and shall indemnify and hold harmless Comtech EF Data Corporation from any claims or liability of such purchaser lessee or user based upon allegatio...

Страница 25: ...port representative with the model number serial number and a description of the problem Request a Return Material Authorization RMA number from the Comtech EF Data Customer Support representative Pac...

Страница 26: ...CDM 710G High Speed Satellite Modem Revision 1 Preface MN CDM710G xx Notes...

Страница 27: ...6APSK and 32APSK Note DVB S and DVB DSNG are not supported Constant Coding and Modulation CCM operation with a single input stream is provided for operation The unit is available in modulator only dem...

Страница 28: ...ess enterprise data distribution Broadband Interactive and Internet services Any networking application relying on o Point to point transmission o Point to multipoint transmission o Arbitrary topology...

Страница 29: ...M 710G performs several key functions It accepts incoming data from the terrestrial interface and converts it into appropriate clock and data signals The modulator operates on the data to frame and en...

Страница 30: ...tor and reverses the process performed by the modulator The demodulator has an FEC decoder that corrects errors incurred during transmission to improve the integrity of the data delivered to the data...

Страница 31: ...and status is provided through the RS 232 RS 485 2Wire or 4Wire port or 10 100 Base T Ethernet port The management Ethernet port supports SNMP Telnet and HTTP Web browser operation 1 3 2 Major Assembl...

Страница 32: ...CDM 710G High Speed Satellite Modem Revision 1 Introduction MN CDM710G 1 6 1 3 3 Dimensional Envelope Figure 1 3 Dimensional Envelope...

Страница 33: ...omprises six individual keyswitches They have a positive click action which provides tactile feedback The user enters data via the keypad and messages are displayed on the VFD The VFD is an active dis...

Страница 34: ...ional 9 pin Type D female Asynchronous Engineering Channel Utility Sect 4 4 P1 Alarms 15 pin Type D male Form C Alarms relay closures P2 Remote 9 pin Type D male Serial Remote Interface RS232 485 J7 E...

Страница 35: ...e point where there are no more paths left to route traffic this is the reason why the CRS 300 supports a limited set of the interface combinations supported by the CDM 710G Table 1 1 Allowable Unit S...

Страница 36: ...port located on the modem rear panel These unique access codes may be purchased at any time from Comtech EF Data FAST System Theory FAST facilitates on location upgrade of the operating feature set w...

Страница 37: ...ancements Users are strongly urged to upgrade the CDM 710G to its most current firmware release for further information refer to Chapter 5 FLASH UPGRADING 1 4 1 CDM 710G Modem Firmware Release Notes F...

Страница 38: ...or Telnet Physical PL Layer Scrambling User specified value one of n 0 to 262 141 per EN 302 307 Pilot Insertion Selection for On or Off Reflash Ethernet port Frequency Reference Selectable Internal...

Страница 39: ...2 fN 0 2 fN 0 40 0 07 fN E 0 4 fN 0 4 fN 0 4 fN 0 25 0 07 fN F 0 4 fN 0 4 fN 0 4 fN 0 40 0 07 fN G 0 8 fN 0 86fN 0 89 fN 0 15 0 07 fN H 0 8 fN 0 86 fN 0 89 fN 1 10 0 07 fN I 0 9 fN 0 93 fN 0 94 fN 0 5...

Страница 40: ...ndard Modular design Simplex or Duplex Dimensional Envelope 1RU 1 72H x 19 00W x 18 65D inches 4 37H x 48 26W x 47 37D cm Weight 15lbs 6 8 kg Front Panel Operational Features Keypad Up down left right...

Страница 41: ...racy 0 5 dB at 25 C Output Power Stability Within 0 5 dB of 25C value over all specified environments Carrier Mute 55 dB below main carrier output Harmonics and Spurious 55 dBc 4 kHz over operating fr...

Страница 42: ...inuous component 1 degrees RMS double sided 100 Hz to 10 MHz Spectral Inversion Normal or Inverted Quadrature Phase Error 2 Quadrature Amplitude Imbalance 0 2 dB maximum Carrier Null 35 dB below an un...

Страница 43: ...ol Rate in MHz dBm 58 dBm at 1 Msps 41 5 dBm at 45 Msps AGC Range 45 dB above minimum Max Composite Level 30 dBc composite to desired up to 10 dBm Acquisition Range 100 kHz programmable in 1 kHz steps...

Страница 44: ...5 1 587196 1 508181 5 18 3 17 5 6 1 654663 1 596093 5 68 3 49 8 9 1 766451 1 727961 6 70 4 23 9 10 1 788612 NA 6 92 4 39 8PSK 3 5 1 779991 1 725319 6 20 3 70 2 3 1 980636 1 922040 7 32 4 35 3 4 2 228...

Страница 45: ...l 1 5 6 Remote Port Operation Description Requirements Comtech EF Data Remote Port See Appendix A REMOTE CONTROL Ethernet Telnet Ethernet transport of standard Remote Control commands Ethernet SNMP Se...

Страница 46: ...100 265560 2 177525 2 177525 97 988646 5 6 2 478562 2 478562 111 535270 2 422276 2 422276 109 002433 8 9 2 646012 2 646012 119 070539 2 585924 2 585924 116 366586 9 10 2 679207 2 679207 120 564315 2...

Страница 47: ...84959 84 823151 3 4 2 118761 2 118761 95 344262 2 077885 2 077885 93 504823 5 6 2 381056 2 381056 107 147541 2 335120 2 335120 105 080386 8 9 2 577778 2 577778 116 000000 2 528046 2 528046 113 762058...

Страница 48: ...CDM 710G High Speed Satellite Modem Revision 1 Introduction MN CDM710G 1 22 Notes...

Страница 49: ...ected and checked for normal operation CAUTION Do not use any cutting tool that will extend more than 1 into the container and cause damage to the unit Unpack and inspect the modem as follows Step Des...

Страница 50: ...Description 2 HW 10 32SHLDR Screw 10 Shoulder 4 HW 10 32FLT Washer 10 Flat 2 HW 10 32SPLIT Washer 10 Split 2 HW 10 32HEXNUT Nut 10 Hex 2 FP 6138 1 Bracket Rear Support 4 HW 10 32x1 2RK Bolt 10 Rack B...

Страница 51: ...lation MN CDM710G 2 3 Figure 2 1 Installation of Optional Rear Mounting Support Brackets KT 6228 2 Equipment Rack Rear Mounting Rail 10 Shoulder Screw 10 Bracket Bolt Support Bracket Back of unit 10 S...

Страница 52: ...lings Figure 2 2 depicts installation of the optional side railings FP SL0006 using standard shop tooling and customer furnished standard shop hardware Optional Side railings FP SL0006 Quantity CEFD P...

Страница 53: ...M table to determine where to forward Ethernet frames By default Ethernet switches will update the CAM table automatically for example if an Ethernet switch sees traffic from Machine A coming in on Po...

Страница 54: ...g Switches Point to Multipoint 3 3 1 Ethernet Network Overview When placing modems in a network there are a number of issues that must be addressed first and foremost on the list of concerns is whethe...

Страница 55: ...serial data interface provides a single connection for the User Data Interface and provides simple Form C relays that route the Ethernet connection from the user connection to either the Traffic or Re...

Страница 56: ...s where all the traffic being transmitted and received is on the same LAN VLAN Figure 3 3 shows a simplified version of the Networking Loop Since there is no router in the network and all the traffic...

Страница 57: ...CDM 710G High Speed Satellite Modem Revision 1 Ethernet Network Configurations MN CDM710G 3 5 This page is intentionally blank...

Страница 58: ...example is shown in Figure 3 5 When the CRS 300 1 10 Redundancy Switch backs up a faulted Traffic Modem the physical port on the router does not change because the Ethernet connection is properly rer...

Страница 59: ...atellite Modem Revision 1 Ethernet Network Configurations MN CDM710G 3 7 Figure 3 5 Wired thru for Hub to Hub with Standard Traffic using Routers Figure 3 6 Wired around for Hub to Hub with Standard T...

Страница 60: ...Routers or Switches A wired thru Ethernet redundancy example is shown in Figure 3 8 When the CRS 300 1 10 Redundancy Switch backs up a faulted Traffic Modem the physical port on the router does not c...

Страница 61: ...evision 1 Ethernet Network Configurations MN CDM710G 3 9 Figure 3 8 Wired thru for Hub to Remotes with Standard Traffic using Routers or Switches Figure 3 9 Wired around for Hub to Remotes with Standa...

Страница 62: ...ure Figure 3 10 Point to Multipoint using Routers A wired thru Ethernet redundancy example is shown in Figure 3 11 When the CRS 300 1 10 Redundancy Switch backs up a faulted Traffic Modem the physical...

Страница 63: ...High Speed Satellite Modem Revision 1 Ethernet Network Configurations MN CDM710G 3 11 Figure 3 11 Wired thru for Point to Multipoint with Routers Figure 3 12 Wired around for Point to Multipoint with...

Страница 64: ...to Multipoint using Switches A wired thru Ethernet redundancy example is shown in Figure 3 14 When the CRS 300 1 10 Redundancy Switch backs up a faulted Traffic Modem the physical port on the Switch d...

Страница 65: ...sion 1 Ethernet Network Configurations MN CDM710G 3 13 Figure 3 14 Wired thru Hub to Remotes Split path Traffic using Switches Point to Multipoint Figure 3 15 Wired around Hub to Remotes Split path Tr...

Страница 66: ...CDM 710G High Speed Satellite Modem Revision 1 Ethernet Network Configurations MN CDM710G 3 14 Notes...

Страница 67: ...l View CDM 710G shown w optional interfaces installed Note The CDM 710G supports Simplex Tx Only or Rx Only operation Duplex Tx Rx operation and 1 1 or 1 N redundant operation The European EMC Directi...

Страница 68: ...pin Type D male Form C Alarms relay closures P2 Remote 9 pin Type D male Serial Remote Interface RS232 485 J7 Ext Ref BNC female External Reference Input Power Ground AC IEC Chassis prime power input...

Страница 69: ...45 The J4 Ethernet connector is a RJ 45 female interface The J4 connector pinout is as follows Pin Description Direction 1 Tx Out 2 TX Out 3 Rx In 4 N A 5 N A 6 Rx In 7 N A 8 N A 4 3 2 J6 ASYNC Chann...

Страница 70: ...Tx COM I O I O I O 5 12 4 Unit Fault De energized Faulted Note 1 2 Unit Fault Energized No Fault Unit Fault Unit NC Unit NO Unit Com I O I O I O 11 3 Rx I Channel Constellation Monitor Rx Q Channel Co...

Страница 71: ...is user selectable for either RS 232 or RS 485 The connector pinout is as follows Pin Description Direction 1 Ground 2 RS 232 Transmit Data Out 3 RS 232 Receive Data In 4 Not Used 5 Not Used 6 RS 485...

Страница 72: ...CDM 710G High Speed Satellite Modem Revision 1 Rear Panel Connector Pinouts MN CDM710G 4 6 Notes...

Страница 73: ...now be sent via the Internet Figure 5 1 via E mail or on CD This chapter outlines the complete upgrading process as follows New firmware can be downloaded via the Internet to an external PC The upgrad...

Страница 74: ...d in this example Any valid writable drive letter can be used CMD Prompt At the command prompt c type mkdir temp or MD temp without quotes mkdir and MD stand for make directory This is the same as cre...

Страница 75: ...Ethernet M C port via a hub or a switch or directly to a PC with a crossover cable IMPORTANT BASE MODEM firmware can only be loaded via the Ethernet M C port do not use the Ethernet Traffic port 7 Se...

Страница 76: ...n by typing bye and closing the DOS window d Verify that the new file loaded using the procedure in Step 1 e Change the desired image to boot from the modem font panel menu SELECT UTIL Firmware Select...

Страница 77: ...ersion shown The user can fully control and monitor the operation of the CDM 710G from the front panel using the keypad and display Nested menus are used that display all available options and prompt...

Страница 78: ...or 1 N redundancy system STORED EVENT Orange There is a Stored Event in the log that may either be viewed from the front panel or retrieved via the remote control interface Off There are no Stored Ev...

Страница 79: ...n executed using ENTER Pressing CLEAR generally returns the display to the previous selection W X Left Right Used to move to the next selection or to move the cursor functions At times they may also u...

Страница 80: ...rmware Version version number varies Pressing any key takes the user to the top level Select menu On most menu screens users will see a flashing solid block cursor that blinks at a once per second rat...

Страница 81: ...Dis Force 1 1 6 3 1 9 CONFIG Alarms Select Tx Intfc1 Intfc2 6 3 2 Monitor Select Alarms Rx_Stats Event Log 6 3 2 1 Monitor Alarms Select Transmit Receive Unit 6 3 2 2 Monitor Rx Stats 6 3 2 3 Monitor...

Страница 82: ...the function of each menu branch along with the section in this chapter that provides information on that branch and its accompanying submenus SELECTION MENU BRANCH DESCRIPTION Config Configuration P...

Страница 83: ...nto Slot 1 or Slot 2 on the back of the unit The menus change depending on the type of interface as of this manual revision Single G 703 HSSI or Gigabit Ethernet GigE are available Int1 CDI 10 1 Singl...

Страница 84: ...is pressed the user is returned to the CONFIG menu When Remote is selected menu operations associated with Local control are disabled and the user may see the following messages and prompts when menu...

Страница 85: ...of the remote control bus connected locally to the M C computer Use the ST arrow keys to change the value then press ENTER Note The Asynchronous character format is FIXED at 8 data bits No parity and...

Страница 86: ...ENTER or CLEAR to return to the previous menu If SNMP Community is selected SNMP Community Read E If Community Read is selected Read Community E public If SNMP Traps is selected SNMP Trap IP Address I...

Страница 87: ...he W X arrow keys then press ENTER If Tx Modulation Type is selected Tx Mod QPSK 8PSK 16QAM 16APSK 32APSK E Use the W X arrow keys to select the Transmit Modulation Type QPSK 8PSK 16APSK or 32APSK the...

Страница 88: ...pilot symbols into the physical layer frame Use the W X arrow keys to make the selection then press ENTER Tx Modulation Pilot Average Peak E The solid cursor indicates the current configuration choic...

Страница 89: ...git Press ENTER when done The Data Rate digits also change as the Symbol Rate values are edited The value of the Data Rate depends upon the code rate modulation type and the Mode type selected When mo...

Страница 90: ...0 1 788612 1 788612 80 487535 1 746049 1 746049 78 572201 8PSK LDPC BCH 3 5 1 45 1 779991 1 779991 80 099585 1 739569 1 739569 78 280616 2 3 1 980636 1 980636 89 128631 1 935658 1 935658 87 104623 3 4...

Страница 91: ...03 1 884959 1 884959 84 823151 3 4 2 118761 2 118761 95 344262 2 077885 2 077885 93 504823 5 6 2 381056 2 381056 107 147541 2 335120 2 335120 105 080386 8 9 2 577778 2 577778 116 000000 2 528046 2 528...

Страница 92: ...equency range The modem disallows settings that exceed the range and will turn off the Tx Carrier CONFIG Tx Pwr TX Power Level On Off Imped E Select Level On Off or Imped using the W X arrow keys then...

Страница 93: ...tting is all 0s To edit use the W X arrow keys to select the digit to be edited then use the ST arrow keys to change the value of the digit Press ENTER when done 6 3 1 3 CONFIG Rx Rx FEC Dem Code SymR...

Страница 94: ...lator automatically resolves frequency inversion Normal or Inverted is not reported in the demodulation Press ENTER or CLEAR to return to the previous menu If Rx Demod Acq is selected Demod Acquisitio...

Страница 95: ...the Alarm Connector that an oscilloscope is connected to monitor I and Q Select Pre Eq or Post Eq using the W X arrow keys then press ENTER If Rx Demod Pilot is selected Rx Demodulation Pilot Off On E...

Страница 96: ...th is not synchronized After synchronization the correct Data Rate appears in the display and the demodulator has automatically resolved the modulation type code rate pilots ON OFF FEC frame length sp...

Страница 97: ...t the threshold use the W X arrow keys to select the digit to be edited then use the arrow keys to change the value of the digit Press ENTER when done If Eb No Alarm Alarm Fault is selected Eb No Alar...

Страница 98: ...nd subsequently the switching logic when the modem is in a 1 1 redundancy configuration Intfc1 E3 T3 STS1 Port1 Ext Clk E Select Port1 or Ext Clk using the W X arrow keys then press ENTER CONFIG Intfc...

Страница 99: ...rsion AMI that is no line coding After making the selection press ENTER If Intfc1 Port1 E3 T3 STS1 Tx is selected Intfc1 Port1 Tx Inv Data Ena Dis E Select Inv Data or Ena Dis using the W X arrow keys...

Страница 100: ...e W X arrow keys to control data inversion then press ENTER If Intfc1 Port1 Rx Data is selected Intfc1 Port 1 Data Rate Rx 34 368000 E Intfc1 Port 1 Data Rate Rx Disabled E This is a read only status...

Страница 101: ...ts in the frame and the maximum buffer size is based upon the integral number of frames that can fit in the buffer memory If Intfc1 Port1 Rx Buffer Size is selected Intfc1 Port1 Rx Buffer 10 0 mSec 03...

Страница 102: ...from the Tx input to clock out the Rx Buffer Ext Clk Derives a clock from a signal input to the Ext Clk connector on the E3 T3 STS 1 Interface Card If Intfc1 Port1 Rx Ena Dis is selected Intfc1 Port1...

Страница 103: ...Datarate Invert E Select Datarate or Invert using the W X arrow keys then press ENTER If Intfc1 Tx Data Datarate is selected Intfc1 Data Rate Tx 032 000000 Mbps This is a read only status message that...

Страница 104: ...d Intfc1 Rx Data Datarate Invert E Select Datarate or Invert using the W X arrow keys then press ENTER If Intfc1 Rx Data Datarate is selected Intfc1 Data Rate Rx 032 000000 Mbps This is a read only st...

Страница 105: ...urce or Invert using the arrow keys then press ENTER If Intfc1 Rx Clock Source is selected Intfc1 Rx Clock Rx Sat Tx Terr Internal This selection determines which source clocks the output of the Rx Bu...

Страница 106: ...he CDM 710G allows only one interface to be active For example if Interface 1 is active and Interface 2 is then enable selected the unit will automatically disable Interface 2 For information on valid...

Страница 107: ...Rx Data is selected Intfc2 Data Rate Rx 075 000000 Mbps E This display is read only If Rx Disabled is displayed the port is turned off Intfc2 Data Rate Rx Disabled E Press ENTER or CLEAR to return to...

Страница 108: ...stics View is selected Intfc1 Statistics FPGA LAN WAN MNG ALL Select FPGA LAN WAN MNG or ALL using the W X arrow keys then press ENTER The available statistics for the Gigabit Ethernet Interface as de...

Страница 109: ...d FCS LAN Oversize In Total frames received from the LAN with a length greater than the maximum size of octets but with a valid FCS LAN Jabber In Total frames received from the LAN with a length great...

Страница 110: ...nt processor with a CRC error that was not counted in the Fragments or Rx Err totals Mng Pause In The number of good flow control frames received from local GBEI management processor Mng Undersize In...

Страница 111: ...and the Gigabit Ethernet Interface GBEI learns connections based on source MAC addresses and ingress ports The hub thinks the remote site network nodes are local to the hub site network and does not...

Страница 112: ...in Local mode When the unit is in Remote mode and the user attempts to select Disable using the W X arrow keys the following message displays follow the prompt as shown THIS UNIT IS CURRENTLY IN REMOT...

Страница 113: ...1 Intfc2 E Select Tx Rx Intfc1 or Intfc2 using the W X arrow keys then press ENTER CONFIG Alarm Mask Tx Tx Alarm Mask None Currently masking of Tx Alarms associated with the modulator is not allowed C...

Страница 114: ...ted Tx AIS Alarm Alarm Fault Mask E Tx AIS Alarm affects the event reporting status upon detection of a Tx AIS condition and subsequently the switching logic when the modem is in a 1 1 redundancy conf...

Страница 115: ...Mask using the arrow keys then press ENTER CONFIG Alarm Mask Intfc1 CDI 60 HSSI Interface Card Intfc1 HSSI Alarms Tx Rx E Select Tx or Rx using the arrow keys then press ENTER If Intfc1 HSSI Alarms T...

Страница 116: ...t using the arrow keys then press ENTER If Live Alarms Transmit is selected TX Traffic GBEI Card PHY Not Connected E This will report only if there are modulator errors otherwise it will report No Err...

Страница 117: ...UCTION for threshold information Additionally Usable Es No Range Typical Modulation Es No Range dB QPSK 0 0 to 14 0 8QPSK 4 5 to 18 5 16APSK 8 0 to 22 0 32APSK 11 5 to 25 00 6 3 2 3 SELECT Monitor Eve...

Страница 118: ...temperature out of range Modem Cooling Fans Framing card sense cooling fan problem Intfc1 has been removed Slot 1 interface card removed Intfc2 has been removed Slot 2 interface card removed 1 5V PSU...

Страница 119: ...nager unlocked Intf1 Rx Buffer Underflow Rx buffer has underrun Slot 1 Intff Rx Buffer Overflow Rx buffer has overflowed Slot 1 Intf2 Rx Buffer Underflow Rx buffer has underrun Slot 2 Intf2Rx Buffer O...

Страница 120: ...s again selected all of the previous values are restored I O Input Output Loop This test mode invokes two distinct loopbacks The first Loopback is an inward loop that takes data being received from th...

Страница 121: ...rd DeMod Card I O Loop Available Some Interfaces Data Driver FEC Encode Modulator Data Driver FEC Decode DeMod Framer Card Mod Card FEC Card DeMod Card Tx Data Tx Data Buffer Rx Data Rx Data Buffers I...

Страница 122: ...eys then press ENTER 6 3 4 1 SELECT INFO Rem Remote M C 100BaseTx IP Addr 192 168 001 006 This display provides the status as applicable of the Remote Monitor Control configuration 6 3 4 2 SELECT INFO...

Страница 123: ...8P 8 PSK 16A 16 APSK 32A 32 APSK 1 2 Code Rate LF FECFrame Type SF Short Frame LF Long Frame 6 3 5 SELECT Save Load Save Load Configuration Save Load E Note When the unit is in Remote mode and the use...

Страница 124: ...d configuration the following screen is displayed New Config has been Saved to Loc 9 E However if the selected location does contain a previously stored configuration the following screen is displayed...

Страница 125: ...AST using the W X arrow keys then press ENTER 6 3 6 1 SELECT UTIL RT Clk Edit Real Time Clock 10 23 51 23 05 06 E Edit the time and date settings of the real time clock Use the W X arrow keys to selec...

Страница 126: ...arrow keys Press ENTER when done 6 3 6 5 SELECT UTIL Firmware IMPORTANT These commands are for DIAGNOSTIC PURPOSES ONLY DO NOT CHANGE an image unless instructed to do so by Comtech EF Data customer s...

Страница 127: ...mage 2 is selected Image x Bulk App Framer FEC Mod Demod Interfaces On the next page Table 6 5 provides an overall summary of examples for each available firmware info screen As shown the first column...

Страница 128: ...od Filters 11 23 05 FW12695 1 1 1 Mod FPGA Mod FPGA 09 12 07 FW12549B 2 2 1 Mod FPGA Mod FPGA 09 12 07 FW12549B 2 2 1 Demod Filters UDD Equalizer Demod Filters UDD Equalizer Demod Filters Dem Filters...

Страница 129: ...he W X arrow keys to move to each character position then editing the character in that position by using the ST arrow keys Once the 20 digit FAST Code has been correctly edited into place press ENTER...

Страница 130: ...CDM 710G High Speed Satellite Modem Revision 1 Front Panel Operation MN CDM710G 6 54 Notes...

Страница 131: ...Sect 4 3 1 for details and pinout information Note Only one remote method can be in control of either Ethernet or Serial while the other can be used for query 7 1 1 Web Server Interface Introduction T...

Страница 132: ...ght HTTP Login Access Levels Default User Names and Passwords are defined as follows CDM 710G High Speed Satellite Modem HTTP Login Access Levels User Interface User Login Access Level Admin User Read...

Страница 133: ...Data logo at the left hand top side as shown at right While the CDM 710G Web Server Interface is depicted throughout this chapter the appearance and function of the CDM 710GL Web Server Interface is f...

Страница 134: ...Config Mdm Modem Configuration Sect 7 3 3 Stats Status Statistics Sect 7 3 4 Maint Maintenance Sect 7 3 5 For a complete and detailed description of each configuration parameter available via each pag...

Страница 135: ...er Interface MN CDM710G 7 5 7 3 1 2 Home Contact Page Figure 7 2 Home Contact Information page Use the Home Contact page Figure 7 2 to obtain basic contact information to reach Comtech EF Data Sales a...

Страница 136: ...s up to 256 characters maximum The CDM 710G Support Web Page uses Simple Mail Transport Protocol SMTP to send E mail to Comtech EF Data Modem Support cdmipsupport comtechefdata com IMPORTANT For this...

Страница 137: ...et up user names passwords the E mail server and the host IP addresses as needed to facilitate communication with the CDM 710G Web Server Network Maintenance MAC Address This parameter is read only an...

Страница 138: ...here you want to send the e mail SMTP Domain Name Destination The Administrator can assign the SMTP Domain Name and Destination This is required if the e mail feature of the Support Page Sect 6 1 4 1...

Страница 139: ...gn up to two SNMP Trap IP addresses The Administrator can assign a SNMP Trap Community String The factory default for this parameter is public The SNMP Trap Community String field can be any combinati...

Страница 140: ...he interfaces installed in Expansion Slot 1 Intfc1 and Expansion Slot 2 Intfc2 In the above example a CDI 60 HSSI Interface Module has been installed in Expansion Slot 1 and a CDI 70 Gigabit Ethernet...

Страница 141: ...present as shown in Figure 7 7 the message Interface Not Installed is displayed in place of an operable configuration window In this example a CDI 10 1 Single G 703 E3 T3 STS1 Interface Module has bee...

Страница 142: ...x parameters IMPORTANT The Tx Rx Interface Types and Framing Modes have higher priority than other parameters and should be configured before setting other parameters For details pertaining to the con...

Страница 143: ...Reboot Saving and Loading Configurations Setting up Redundancy Operation Setting the Date and Time Setting the Clock Mode Selecting the Test Mode Re centering the Buffer Assigning a Circuit ID Setting...

Страница 144: ...istics windows 7 3 4 1 Stats Modem Status Figure 7 10 Stats Modem Status page Use the Stats Modem Status page Figure 7 10 to review read only status information pertaining to General modem operating a...

Страница 145: ...ect to buffer the next group of five stored events into the scrollable Events window Clear Events Log Select to wipe clean the stored events log Initialize Events Pointer Select to reset the log s int...

Страница 146: ...e Figure 7 12 Maint Unit Info page Use the Maint Unit Info page Figure 7 12 to review a read only scrollable status window which provides information about the currently loaded Bootrom for Image 1 and...

Страница 147: ...ile is a tree of nodes that is unique to a particular device There are three MIB files associated with the CDM 710G MIB File Name Description Fw10874 2 mib ComtechEFData MIB file ComtechEFData MIB fil...

Страница 148: ...e community string is entered into the MIB Browser or Network Node Management software and is used to authenticate users and determine access privileges to the SNMP agent The user defines three Commun...

Страница 149: ...ovides parameters necessary to configure the SNMP interface Interface TX Group Provides parameters that control the modulator options Interface RX Group Provides parameters that control the demodulato...

Страница 150: ...CDM 710G High Speed Satellite Modem Revision 1 SNMP Interface MN CDM710G 8 4 Notes...

Страница 151: ...nterface for two primary functions Equipment M C via the standard equipment Remote Control protocol Equipment M C via Comtech Monitor and Control System CMCS application The Telnet interface requires...

Страница 152: ...S cannot translate a r to a r n for the messages coming from Telnet Server the multi line command response for example FRW response will be displayed as one line with the latter lines overwriting the...

Страница 153: ...CDM 710G High Speed Satellite Modem Revision 1 Telnet Interface MN CDM710G 9 3 The following screen captures depict examples of HyperTerminal configured as Telnet Client...

Страница 154: ...essor which responds to it as if it was a serial remote command To summarize Start of Packet is either a or a where is used to send a command query to the modem and is the modem response Defines the a...

Страница 155: ...e modem locks its internal IF synthesizers and signal processing circuitry to the Ext Ref signal It is a low phase noise highly stable signal When the Ext Ref is used it replaces the internal referenc...

Страница 156: ...out of the modem and send the received data to the DTE depending upon the data interface The Rx Buffer Clocks include Tx Terr TT or SD Int Clk derived from Int Ref or Ext Ref or Ext Clk Some interfac...

Страница 157: ...SD signal applied to the Tx input Internal Clock and Rx Loop Timed operation do not apply to G 703 applications 10 2 2 CDI 10 1 Single G 703 Interface Receive Clocking When the Rx Buffer is disabled t...

Страница 158: ...n operating with HSSI interfaces always send ST to the DTE and assure that TT derived from ST is delivered to the DCE Rx Loop Timed where ST is programmed to a rate derived from the Rx Sat clock from...

Страница 159: ...ernal The Internal Clock comes from the modem It is derived from either the Ext Ref J7 or Int Ref oscillator in the main part of the modem not from the data interface 10 4 CDI 70 10 100 1000 Base T Gi...

Страница 160: ...CDM 710G High Speed Satellite Modem Revision 1 Clock Modes MN CDM710G 10 6 Notes...

Страница 161: ...decoding In this process the data initially corrected by the LDPC decoder is re encoded and run through the decoder again to correct additional errors Key to this is the soft decision output from the...

Страница 162: ...gin and specifies performance The other difference is the use of PER packet error rate based upon a 188 or 204 byte MPEG frame size instead of BER bit error rate Note The CDM 710G uses only a 188 byte...

Страница 163: ...6 669 QPSK 9 10 6 92 1 788612 0 559 6 430 1 746049 0 573 6 586 8PSK 3 5 6 20 1 779991 0 562 6 461 1 739569 0 575 6 611 8PSK 2 3 7 32 1 980636 0 505 5 806 1 935658 0 517 5 941 8PSK 3 4 8 61 2 228124 0...

Страница 164: ...6 802 QPSK 9 10 7 22 NA NA NA NA NA NA 8PSK 3 5 6 50 1 725319 0 580 6 665 1 692033 0 591 6 797 8PSK 2 3 7 62 1 922040 0 520 5 983 1 884959 0 531 6 101 8PSK 3 4 8 91 2 118761 0 472 5 428 2 077885 0 481...

Страница 165: ...CDM 710G High Speed Satellite Modem Revision 1 Forward Error Correction Options MN CDM710G 11 5 Figure 11 1 DVB S2 QPSK Packet Error Rate versus Es No QPSK 1 4 1 3 and 2 5 Information Only...

Страница 166: ...CDM 710G High Speed Satellite Modem Revision 1 Forward Error Correction Options MN CDM710G 11 6 Figure 11 2 DVB S2 8PSK Packet Error Rate versus Es No...

Страница 167: ...CDM 710G High Speed Satellite Modem Revision 1 Forward Error Correction Options MN CDM710G 11 7 Figure 11 3 DVB S2 16APSK Packet Error Rate versus Es No...

Страница 168: ...CDM 710G High Speed Satellite Modem Revision 1 Forward Error Correction Options MN CDM710G 11 8 Figure 11 4 DVB S2 32APSK Packet Error Rate versus Es No...

Страница 169: ...the modulator and demodulator are more problematic at low data rates and generally negligible at higher data rates Delay for the Gigabit Ethernet and HSSI interfaces is shown in Figure 11 5 and Figur...

Страница 170: ...CDM 710G High Speed Satellite Modem Revision 1 Forward Error Correction Options MN CDM710G 11 10 Figure 11 6 CDM 710G HSSI Latency With Modem In IF Loopback...

Страница 171: ...s Data Communications Equipment DCE where Tx data enters the data interface and Rx data exits The plug in interface has full duplex capability In addition the module is automatically configured for si...

Страница 172: ...s and installable combinations refer to Sect 1 3 5 Allowable Data Interface Combinations 12 2 Physical Description Figure 12 2 depicts the block diagram of the interface Figure 12 3 shows the rear pan...

Страница 173: ...Satellite Modem Revision 1 Single G 703 E3 T3 STS 1 Interface CDI 10 1 MN CDM710G 12 3 12 3 CDI 10 1 Connector Pinouts Connector Description Direction Connector Type Ext Clk J1 In BNC Female Rx J2 Dat...

Страница 174: ...Test Baseband Loopback at interface Interface Loopback through interface module Hot Swap Capability None Interfaces G 703 Unbalanced Connector Type Signals Supported Data Rate Tx and Rx Data Rates Li...

Страница 175: ...The plug in interface has full duplex capability In addition the module is automatically configured for simplex transmit or simplex receive operation when the module is plugged into a simplex chassis...

Страница 176: ...iode LED labeled Activity is lit green when the interface is enabled The CDI 60 HSSI interface provides A single HSSI interface DCE Connection ST clock is sourced to the terrestrial interface for use...

Страница 177: ...C LC undefined 5 30 From DCE Not used Send Timing ST 114 6 31 From DCE Signal Ground SG 102 7 32 Ground DTE Available TA 108 2 8 33 to DCE Terminal Timing TT 113 9 34 to DCE Loopback circuit A LA 143...

Страница 178: ...Data Relationship The data transitions occur during the OFF to ON transition of the clock Data is stable during the ON to Off transition of the clock Tx Clock Modes TT Input clock continuous ST outpu...

Страница 179: ...5 13 5 Environmental And Physical Specifications Item Requirement Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 40 to 70 C 40 to 158 F Humidity 95 maximum non condensing Mechanical...

Страница 180: ...CDM 710G High Speed Satellite Modem Revision 1 HSSI Interface CDI 60 MN CDM710G 13 6 Notes...

Страница 181: ...Base T connectivity and supports data rates from 1 Mbps to 155 Mbps IP traffic entering the interface is encapsulated in HDLC protocol for transmission over the satellite link In normal mode the packe...

Страница 182: ...face 14 2 Physical Description The CDI 70 data interface is implemented on a 3 95 x 7 022 inch 10 03 x 17 83 cm PCB Connectivity to the CDM 710G is implemented with a 96 pin DIN receptacle The LAN int...

Страница 183: ...E 802 3ab 1000Base T copper compliant female RJ 45 connector This connector features Light Emitting Diode LED indicators labeled LINK STATUS and LINK ACTIVITY The connector pinout is as follows Pin De...

Страница 184: ...e card NO LEDs Link status link activity Monitor and Control M C Data Rate 1 5 to 155 52 Mbps Packet Filtration Parameters generic IP address match value configuration for management packets Optional...

Страница 185: ...link errors Rx packet count Tx packet count Management Port Statistics Ingress good oclets Ingress bad oclets Ingress unicast packets Ingress broadcast packets Ingress multicast packets Ingress pause...

Страница 186: ...external PC The upgrade can be performed without opening the unit by simply connecting the GigE Interface s J1 10 100 1000 Ethernet Traffic port to the Ethernet port of a computer Once downloaded the...

Страница 187: ...ary folder that was created in Step 1 a At least four 4 files must be extracted file naming is approximate FW12738x bin Bulk Image file where x is the revision ReleaseNotes_FW12738_vxxx pdf Where xxx...

Страница 188: ...e Successful appears in the status field of the CReflash exe application window a similar message displays on the modem s front panel h Cycle power to the CDM 710G to have the new firmware loaded on t...

Страница 189: ...acts like a direct wire connection and passes all Ethernet traffic and broadcasts Figure 14 4 is an example of using the GigE Interface to bridge a remote host on a common LAN over the satellite It al...

Страница 190: ...CDM 710G High Speed Satellite Modem Revision 1 10 100 1000 Base T Gigabit Ethernet GigE Interface CDI 70 MN CDM710G 14 10 Figure 14 5 M C Port Assignment Example IP Address NOT on Common LAN...

Страница 191: ...via one of the pairs Many target devices are connected to this pair which all simultaneously receive data from the controller The controller is the only device with a line driver connected to this pa...

Страница 192: ...ket are printable ASCII characters less than ASCII code 127 In this context the Carriage Return and Line Feed characters are considered printable All messages from controller to target require a respo...

Страница 193: ...entifies the subject of the message Wherever possible the instruction codes have been chosen to have some significance For example TFQ for Transmit FreQuency etc This aids in the readability of the me...

Страница 194: ...he character Example XYZ ASCII code 42 The code target to controller is only used as follows If the controller sends an instruction to set a parameter to a particular value then if the value sent in t...

Страница 195: ...34 IMP X X A 8 A 20 A 29 SNO X A 12 A 26 A 42 DLK X A 17 A 34 IPA X X A 8 A 21 A 38 R SWR X A 12 A 26 A 42 IPG X X A 10 A 21 A 38 RAR X X A 22 A 39 W E ITF X A 10 A 21 A 38 RBS X X A 22 A 29 A 39 T EB...

Страница 196: ...uery Tx Code Rate where 0 Rate 3 4 1 Reserved 2 Rate 3 5 3 Rate 4 5 4 Rate 5 6 5 Rate 8 9 6 Rate 9 10 7 Rate 2 3 8 Rate 1 2 Example TCR 0 which is Rate 3 4 NOTE Please refer to Sect 1 8 Summary of Spe...

Страница 197: ...99 Example DAY 240457 April 24 2057 DAY DAY DAY DAY DAY DAY ddmmyy Enable Redundancy Switch Mode ESW 1 byte value of 0 or 1 Command or Query Set redundancy mode where 0 Disable 1 Enable Example ESW 1...

Страница 198: ...d DSNG only 4 45 0 Msps S1 and DSNG only d S W option Tx 8PSK 0 Not installed 1 Installed e S W option Tx 16 QAM 0 Not installed 1 Installed f S W option Tx 16APSK 0 Not installed 1 Installed g S W op...

Страница 199: ...18 0 Volts Framer Card A FLASH Checksum B FEC1 Load C FEC2 Load D Interface 1 Load E Interface 2 Load F 192 MHz PLL G External Reference H Framer Card Temperature I Modem Temperature J Cooling Fans K...

Страница 200: ...e IPG 010 006 030 001 IPG IPG IPG IPG IPG IPG xxx xxx xxx xxx Interface Type N A 2 bytes Query Only Interface Type where s Defines which interface slot 1 or 2 x Defines the interface type where 0 Rese...

Страница 201: ...t 2 MSK MSK MSK MSK MSK MSK abcdefghijkLmxxx Soft Reboot RBT 1 1 byte Command Only Soft Reboot 1 Reboot System RBT RBT RBT N A RBT Retrieve next 5 unread Stored Events N A 75 bytes Query Only Unit ret...

Страница 202: ...Crossover Disabled SCX SCX SCX SCX SCX s SCX a Gigabit Learning Mode SLM 2 bytes Command or Query s Slot2 Only a 1 GBEI Learning Enabled a 0 GBEI Learning Disabled SLM SLM SLM SLM SLM s SLM a Serial...

Страница 203: ...9 bytes Command or Query Tx Frequency in MHz 52 to 88 MHz and 104 to 176 MHz 70 140 Modulator 950 to 1950 MHz L Band Modulator Resolution 100Hz Example TFQ 0950 0000 TFQ TFQ TFQ TFQ TFQ TFQ xxxx xxxx...

Страница 204: ...e value of the internal temperature in the form of sxxx degrees C Where s is the sign and and xxx is the number of degrees Example TMP 026 TMP TMP TMP TMP TMP sxxx Tx Pilot On Off TPI 1 byte Command o...

Страница 205: ...rameter Type Command Instruction Code and Qualifier Arguments for Command or Response to Query Description of Arguments Response to Command Query Instruction Code and Qualifier Response to Query Rx Mo...

Страница 206: ...tween 1 to 99 Returns 00 if demodulator is unlocked Note Command not valid for Gigabit interface Example BFS 133 which is 33 on interface slot 1 channel 1 N A BFS s BFS sxx Rx BER Alarm Threshold BTH...

Страница 207: ...ent configuration in the specified configuration location 0 to 9 Example CST 4 store the current configuration in location 4 CST CST CST CST N A N A Real time Clock Date DAY 6 bytes Command or Query A...

Страница 208: ...1 22 5 Msps 2 30 0 Msps 3 37 5 Msps S1 DSNG only 4 45 0 Msps m S W option Rx 8PSK 0 Not installed 1 Installed n Reserved o S W option Rx 16APSK 0 Not installed 1 Installed p S W option Rx 32APSK 0 No...

Страница 209: ...ference Frequency where 0 Internal 1 External 1 MHz 2 External 2 MHz 3 External 5 MHz 4 External 10 MHz 5 External 20 MHz Example ERF 0 External reference not used uses internal ERF ERF ERF ERF ERF ER...

Страница 210: ...IP GIP GIP GIP s GIP siii iii iii iii nn Gigabit Interface Management MAC Address GMC N A Query Only s Defines Interface slot 2 Example To get MAC address for Gigabit in Slot 1 GMC 2 GMC 2s0006B000471...

Страница 211: ...gement port in the format xxx xxx xxx xxx where xxx xxx xxx xxx is the IP address Example IPG 010 006 030 001 IPG IPG IPG IPG IPG IPG xxx xxx xxx xxx Interface Type N A 2 bytes Query Only Interface Ty...

Страница 212: ...xxx Alarm masks for interface slot Slot 2 Ebno Rx Agc MSK MSK MSK MSK MSK MSK abcdefghijkLmxxx Number of Unread stored Events N A 3 bytes Query Only Unit returns the Number of stored Events which rema...

Страница 213: ...Inverted Note Command valid with HSSI Example RCI 11 selects Inverted RX Clock Slot 1 RCI RCI RCI RCI RCI s RCI sx see description of arguments Rx Clock Source RCK 2 bytes Command or Query Rx Clock S...

Страница 214: ...arameters Rx Buffer Frame where s Defines which interface slot 1 or 2 x Rx Ternary Code where 0 None Valid for E3 T3 and STS 1 1 G 751 Valid for E3 2 G 752 Valid for T3 3 G 753 Valid for E3 4 STS 1 Va...

Страница 215: ...IE RIE s RIE sx Retrieve next 5 unread Stored Events N A 75 bytes Query Only Unit returns the oldest 5 Stored Events which have not yet been read over the remote control in the form CR Sub body CR Sub...

Страница 216: ...GBEI Learning Disabled SLM SLM SLM SLM SLM s SLM a Serial Number N A 9 bytes Query Only Used to query the unit 9 digit serial number Unit returns its S N in the form xxxxxxxxx Example SNO 176500143 S...

Страница 217: ...rameter can override any of the parameters of lower priority Parameter Type Command Instruction Code and Qualifier Arguments for Command or Response to Query Description of Arguments Response to Comma...

Страница 218: ...lid only with CDI 10 1 G 703 interface Example EFI 14 Selects 10MHz on slot 1 EFI EFI EFI EFI EFI s EFI sx see description of arguments E3 T3 STS1 Mode Select ETS 2 bytes Command or Query Sets the E3...

Страница 219: ...RBS RBS RBS RBS RBS s RBS sxx x see description of arguments ReCenter Buffer RCB 2 bytes Command only Forces the software to recenter the receive Plesiochronous Doppler buffer s Defines which interfac...

Страница 220: ...TCI s TCI sx see description of arguments Tx Data Invert TDI 2 bytes Command or Query Invert Transmit Data where s Defines which interface slot 1 or 2 x Invert Transmit Data where 0 Normal 1 Inverted...

Страница 221: ...ace Slot Enable Disable where s Defines which interface slot 1 or 2 x Tx Interface Status where 0 Disabled 1 Enabled Example TIE 11 Enables transmit interface TIE TIE TIE TIE TIE s TIE sx Tx Location...

Страница 222: ...s sign xx x Tx Output power level 05 0 and 20 0 dBm L Band 25 0 to 05 0 dBm 70 140 MHz 20 0 to 00 0 dBm Note Beyond 20 dBm is beyond the specification Example TPL 13 4 TPL TPL TPL TPL TPL TPL sxx x T...

Страница 223: ...if Demodulator unlocked This is automatically detected on demod acquisition N A RMD RMD x Rx FEC Code Rate N A 1 byte Query Only Rx Code Rate where 0 Rate 3 4 1 Reserved 2 Rate 3 5 3 Rate 4 5 4 Rate...

Страница 224: ...CLD CLD CLD CLD N A N A Configuration Save CST 1 byte Command Only Stores the current modulator configuration in the specified configuration location 0 to 9 Example CST 4 store the current configurati...

Страница 225: ...ramer Card A FLASH Checksum B FEC1 Load C FEC2 Load D Interface 1 Load E Interface 2 Load F 192 MHz PLL G External Reference H Framer Card Temperature I Modem Temperature J Cooling Fans K Interface 1...

Страница 226: ...Card 3 Demod Unlocked 4 FPGA Temperature Demodulator Card 5 Ber Limit excedded 6 AGC Level Out of Range 7 Eb No Limit Exceeded 8 Demodulator Synth 1 PLL 9 Demodulator Synth 2 PLL A SERDES Demod to Fr...

Страница 227: ...SN 022 ESN ESN ESN ESN ESN xxxx Enable Redundancy Switch Mode ESW 1 byte Command or Query Set redundancy mode where 0 Disable 1 Enable Example ESW 1 Enable redundancy mode ESW ESW ESW ESW ESW ESW x Fi...

Страница 228: ...gement port in the format xxx xxx xxx xxx where xxx xxx xxx xxx is the IP address Example IPG 010 006 030 001 IPG IPG IPG IPG IPG IPG xxx xxx xxx xxx Interface Type N A 2 bytes Query Only Interface Ty...

Страница 229: ...in milliseconds where s Defines which interface slot 1 or 2 xx x Rx Buffer Size HSSI 5 0 to 32 0 ms in 0 1 ms steps GBEI N A E3T3STS1 5 TO 64 MS IN 5MS STEPS Example RBS 130 0 selects 30 0 ms on inter...

Страница 230: ...e unit will always be online Example RED 0 force unit offline RED RED RED RED RED RED x see description of arguments Rx Frequency Offset N A 5 bytes Query only Unit returns the value of the measured f...

Страница 231: ...ry Only Unit returns the oldest 5 Stored Events which have not yet been read over the remote control in the form CR Sub body CR Sub body CR Sub body CR Sub body CR Sub body where Sub body ABCddmmyyhhm...

Страница 232: ...er SCX 2 bytes Command or Query s Slot 2 Only a 1 GBEI Cable Auto Crossover Enabled a 0 GBEI Cable Auto Crossover Disabled SCX SCX SCX SCX SCX s SCX a Serial Number N A 9 bytes Query Only Used to quer...

Страница 233: ...uments for Command or Response to Query Description of Arguments Response to Command Query Instruction Code and Qualifier Response to Query Unit Test Mode TST 1 byte Command or Query Test Mode where 0...

Страница 234: ...ich interface slot is enabled 1 indicates that slot 1 is enabled 2 indicates that slot 2 is enabled I Indicates the interface type for the interface block 4 indicates G 703 2 indicates Gigabit Etherne...

Страница 235: ...Sequence same as TGS n Tx Location of Pilot same as TLP o Tx Transport Stream read only xxxxxxxxxx Spare bytes Rx Block consists of 50 bytes for Receive configuration The format is aaaa aaaabcc ccccc...

Страница 236: ...parameter c Rx Clock Source same as RCK omit interface slot parameter dd d Rx Buffer Size same as RBS omit interface slot parameter f ET3STS1 Type same as ETS omit interface slot parameter e E3T3STS1...

Страница 237: ...ision Set the Resolution Bandwidth of the Spectrum Analyzer to 20 of the symbol rate Use video filtering and or video averaging to reduce the variance in the displayed trace to a low enough level that...

Страница 238: ...d this corresponds to an Eb No of approximately 2 8 dB DVB S2 The relationship used to derive the table values is as follows only simple way for DVB S2 Eb No 10 log10 10 Co No No 10 1 10 log10 Spectra...

Страница 239: ...9 7 1 6 6 6 1 5 8 5 7 5 4 5 3 5 3 4 9 4 4 3 9 3 6 3 6 9 0 8 4 11 5 10 2 9 4 8 5 7 7 7 2 6 7 6 4 6 2 5 9 5 9 5 9 5 4 4 9 4 5 4 2 4 1 9 5 9 0 12 1 10 8 10 0 9 0 8 2 7 8 7 3 7 0 6 8 6 5 6 5 6 5 6 0 5 5 5...

Страница 240: ...9 10 6 10 1 9 9 9 7 9 4 9 3 9 2 8 9 8 7 8 4 8 4 15 5 15 4 11 2 10 7 10 4 10 2 9 9 9 9 9 7 9 4 9 2 8 9 8 9 16 0 15 9 11 7 11 2 10 9 10 7 10 4 10 4 10 2 9 9 9 7 9 5 9 4 16 5 16 4 12 2 11 7 11 4 11 2 10...

Страница 241: ...ccess code to enable configuration of the available hardware The access code can be purchased at any time from Comtech EF Data Once obtained from Comtech EF Data Customer Support the access code is ma...

Страница 242: ...ENTER b Scroll through the modem Options using the arrow keys and note which options are Installed or Not Installed Any that are Not Installed may be purchased as a FAST upgrade View Options 01 IF Mod...

Страница 243: ...ENTER when done The modem responds with Configured Successfully if the new FAST option is accepted Configured Successfully ENTER or CLEAR Press ENTER or CLEAR as directed The modem will then reset to...

Страница 244: ...ds remaining available for the free Demo Mode When enabled Demo Mode allows access to ALL CDM 710G FAST options for 604800 seconds 7 full days Demo Mode may be turned on and off an unlimited number of...

Страница 245: ...3 1 760 x 103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoirdupois Pound Troy Kilogram 1 gram 0 03527 0 032...

Страница 246: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...

Отзывы: