Revision 11
Front Panel Operation
MN/CDM710.IOM
5–28
(CONFIG: Intfc1 HSSI) Rx
Æ
Buffer
Intfc1 Rx Buffer:
Size Recenter (
E)
Select
Size
or
Recenter
using the
W
X
arrow keys, then press
ENTER
.
(CONFIG: Intfc1 HSSI) Rx
Æ
Buffer
Æ
Size
Intfc1 Rx Buffer Size:
10.0 mSec (0343,680 Bits)
The range of Rx Buffer Size values is from
5.0
to
32.0
mSec in
0.1
mSec increments. To
edit, use the
W
X
arrow keys to select the digit to be edited, then use the
ST
arrow keys to
change the value of that digit. Press
ENTER
when done.
(CONFIG: Intfc1 HSSI) Rx
Æ
Buffer
Æ
Recenter
Intfc1 Rx Buffer Fill:
(046%) ReCenter (
E)
This screen indicates the current buffer fill status – in this example, the percentage is
listed at 46%. To reset the buffer to the midpoint (50%), select
ReCenter
using the
◄
►
arrow keys, then press
ENTER
.
(CONFIG: Intfc1 HSSI) Rx
Æ
Clock
Intfc1 Rx Clock:
Source Invert (
E)
Select
Source
or
Invert
using the
◄
►
arrow keys, then press
ENTER
.
(CONFIG: Intfc1 HSSI) Rx
Æ
Clock
Æ
Source
Intfc1 Rx Clock:
Rx-Sat Tx-Terr Internal
This selection determines which source clocks the output of the Rx Buffer for delivering
data to the Rx port at the user interface. Select
Rx-Sat, Tx-Terr
, or
Internal
using the
W
X
arrow keys, then press
ENTER
. Note the following:
Rx-Sat
(default)
Effectively disables the Rx Buffer because the input and output clocks are the
same. Normally, the Rx Buffer is set for minimum when Rx-Sat is selected.
Tx-Terr
Uses the clock from the Tx input (TT) to clock out the Rx Buffer.
Internal
Derives a clock from the internal 10 MHz reference clock.
Содержание CDM-710
Страница 2: ......
Страница 8: ...This page is intentionally blank ...
Страница 26: ...CDM 710 Broadcast Satellite Modem Revision 11 Preface MN CDM710 IOM xx Notes ...
Страница 64: ...CDM 710 Broadcast Satellite Modem Revision 11 Flash Upgrading MN CDM710 IOM 4 6 Notes ...
Страница 120: ...CDM 710 Broadcast Satellite Modem Revision 11 Front Panel Operation MN CDM710 IOM 5 56 Notes ...
Страница 144: ...CDM 710 Broadcast Satellite Modem Revision 11 Ethernet Management MN CDM710 IOM 6 24 Notes ...
Страница 230: ...CDM 710 Broadcast Satellite Modem Revision 11 Appendix A MN CDM710 IOM A 56 Notes ...
Страница 236: ...CDM 710 Broadcast Satellite Modem Revision 11 Eb No Measurement MN CDM710 IOM B 6 Notes ...
Страница 242: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...