Errata
A
for
MN/CDM710.IOM
Rev
11
Update
'FLT'
Serial
Remote
Control
Query
ER-CDM710-EA11
THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE!
PLM CO C-0025029
Page
3
of
4
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and
Status
N/A
4 bytes
Query only.
Unit returns the current fault and status codes for the Unit (hardware), Tx Traffic
and Rx Traffic, in the form abcd, where:
a = Unit Faults:
0=No faults
1=Framer FPGA Load
2=Power supply fault, +1.5 Volts, Framer Card
3=Power supply fault, +1.5 Volts, Interface #1
4=Power supply fault, +1.5 Volts, Interface #2
5=Power supply fault, +3.3 Volts, Framer Card
6=Power supply fault, +5.0 Volts, Framer Card
7=Power supply fault, +12.0 Volts, Framer Card
8=Power supply fault, -12.0 Volts, Framer Card
9=Power supply fault, +18.0 Volts, Framer Card
A=FLASH Checksum
B=FEC1 Load
C=FEC2 Load
D=Interface #1 Load
E=Interface #2 Load
F=192 MHz PLL
G=External Reference
H=Framer Card Temperature
I=Modem Temperature
J=Cooling Fans
K=Interface #1 Removed
L=Interface #2 Removed
b = Tx Traffic Status:
0=No faults
1= +1.5V Power Supply Unit (Modulator Card)
2= FPGA Failed to Load (Modulator Card)
3= Symbol Rate PLL Clock
4= Tx Synthesizer Unlocked
5= Tx Digital Clock Manager Unlocked
6= I & Q Baseband Channels are Inactive
7= FPGA Temperature (Modulator Card)
8= Reserved
9= ASI Port Transmit FIFO Empty (Interface 1)
A= Reserved
B= ASI Port Transmit FIFO Full (Interface 1)
FLT?
FLT*
FLT#
FLT? FLT=abcd
e
d=
New faults since last check
Note:
Each section has faults
listed in order of priority. For
each section, only the highest
priority fault is returned. There
maybe multiple faults for each
section, but only the highest
fault is returned.
Содержание CDM-710
Страница 2: ......
Страница 8: ...This page is intentionally blank ...
Страница 26: ...CDM 710 Broadcast Satellite Modem Revision 11 Preface MN CDM710 IOM xx Notes ...
Страница 64: ...CDM 710 Broadcast Satellite Modem Revision 11 Flash Upgrading MN CDM710 IOM 4 6 Notes ...
Страница 120: ...CDM 710 Broadcast Satellite Modem Revision 11 Front Panel Operation MN CDM710 IOM 5 56 Notes ...
Страница 144: ...CDM 710 Broadcast Satellite Modem Revision 11 Ethernet Management MN CDM710 IOM 6 24 Notes ...
Страница 230: ...CDM 710 Broadcast Satellite Modem Revision 11 Appendix A MN CDM710 IOM A 56 Notes ...
Страница 236: ...CDM 710 Broadcast Satellite Modem Revision 11 Eb No Measurement MN CDM710 IOM B 6 Notes ...
Страница 242: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...