3.3.2.2 AC Operation – Replacing Fuses
The CDD-56xA/L uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral connections.
The fuses are contained within a fuse holder that is press-fit into the body of the IEC power module
(located on the rear panel, Figure 3-4).
Figure 3-4. Replacing CDD-56xA/L AC Fuses
WARNING
Disconnect the power supply first.
To replace the fuse(s):
1.
Disconnect the power supply.
2.
Unseat the fuse holder from the IEC power module.
a.
Use the slot to pry the holder outward from the IEC power module.
b.
Pull the holder straight out, and then swing the holder away from the module.
3.
Remove and replace the T2 (2.00 Amp) fuses as needed.
4.
Re-seat the fuse holder in the IEC power module.
CAUTION
For continued operator safety, always replace the fuses with the correct type and rating.
See Table 3-2.
Table 3-2 Correct Fuses
Model
Input
Power Consumption
Fuse
CDD-564A
AC
100-240VAC, 50-60HZ, 0.62-0.26A 1A
CDD-564AL
AC
100-240VAC, 50-60HZ, 1.24-0.52A 2A
CDD-562AL
AC
100-240VAC, 50-60HZ, 0.75-0.31A 1A
CDD-564A
DC
43-60VDC, 1.43-1.1A
2A
CDD-564AL
DC
43-60VDC, 2.9-2.1A
4A
CDD-562AL
DC
43-60VDC, 1.73-1.25A
2.5A
Содержание CDD-562AL
Страница 2: ......
Страница 4: ...Errata A ER CDD562564AL EA0 Rev PLM C 0034791 BLANK PAGE...
Страница 6: ...ER CDD562564L EB0 Rev...
Страница 8: ...ii Blank Page...
Страница 48: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 Installation and Startup MN CDD562AL564AL 2 6 BLANK PAGE...
Страница 82: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 Updating Firmware MN CDD562AL564A L 5 10 BLANK PAGE...
Страница 86: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 FAST Activation Procedure MN CDD562AL564AL 6 4 BLANK PAGE...
Страница 106: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 Quick Start Guide MN CDD562AL564AL 8 10 BLANK PAGE...
Страница 212: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 HTTP Web Server Interface MN CDD562AL564AL 10 42 BLANK PAGE...
Страница 232: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 Forward Error Correction MN CDD562AL564AL A 20 Blank Page...
Страница 236: ...CDD 562AL 564A L Multi Channel Demodulator Revision 0 Eb N0 Measurement MN CDD562AL564AL B 4 BLANK PAGE...
Страница 243: ......
Страница 244: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...