MBT-4000 Multi-Band Transceiver System
Revision 6
Remote Control
MN/MBT4000.IOM
Remote Control
A–12
MN/MBT4000.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Concise Utility
Status
N/A
MBT
21 bytes
alphanumeric
Query only.
Used to query the utility status of the MBT-400 Base Unit,
response is comma delimited, where:
aaaa=Physical Address
bbbb=Remote Baud Rate
Example:
<0001/CUS?
>0001/CUS=aaaa,bbbb{cr}{lf}
N/A
CUS?
CUS=x…x
(see description
for details of
arguments)
Set RTC
(Real-Time-
Clock) Date
DAT=mmddyy
All
6 bytes,
numeric
Command or Query.
A command in the form mmddyy, where;
dd = day of the month, between 01 and 31
mm = month of the year, between 01 and 12
yy = year, between 00 and 96 (2000 to 2096)
Example:
DAT=042503 would be April 24, 2003.
DAT= (message OK)
DAT? (received OK,
but invalid arguments
found)
DAT* (message OK,
but not permitted in
current mode)
DAT?
DAT=mmddyy
(same format as
command
arguments)
Enable Aux
Com
Fault Input
Monitoring
EAM=nm
MBT
n=1 AUX
COMM1
2=AUX
COMM2
m=0
(disabled), 1
(monitoring
enabled)
Command or Query.
EAM controls monitoring of external fault logic inputs to Aux
Comm connectors (J8/J9 pin F). If enabled and external fault
input is at Logic 1 ( > 2.6 vdc) a fault will be reported.
Note:
The inputs may be driven by a contact closure relay.
They have an internal pull-up resistor (4.7k) to +5 vdc.
Example:
EAM=21
EAM=(message OK)
EAM?(received OK,
but invalid arguments
found)
EAM?n
EAM=nm
(same format as
command
arguments)
Operating
RF Frequency
FRE=xxxxx.xxx
BDC
BUC
9 bytes,
numeric
Command or Query
Valid Operating RF frequency, in MHz.
For Ku BDCs:
FRE values: 10950-11700 MHz an LO of 10000 MHz is activated
FRE values: 11701-12250 MHz an LO of 10700 MHz is activated
FRE values: 12251-12750 MHz an LO of 11300 MHz is activated
Example:
FRE=11300.000
FRE=(message OK)
FRE? (received OK,
but invalid arguments
found)
FRE* (message OK,
but not permitted in
current mode)
FRE! (command not
accepted by MBT-
4000 base unit. It
must be addressed
to BUC or BDC sub-
units)
FRE?
FRE=xxxxx.xxx
(see description
of arguments)
Retreive
Firmware
Number
N/A
All
Query only
Gets the Firmware Number of the unit.
Example:
FRW=FW12001’cr’’lf’
N/A
FRW?
FRW=FWxxxxx
Содержание MBT-4000
Страница 8: ...MBT 4000 Multi Band Transceiver System Revision 6 Table of Contents TOC 6 MN MBT4000 IOM BLANK PAGE ...
Страница 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Страница 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Страница 21: ...1 7 Notes ...
Страница 35: ...MBT 4000 Multi Band Transceiver System Revision 6 External Connectors 3 12 MN MBT4000 IOM Notes ...
Страница 38: ...MBT 4000 Multi Band Transceiver System Revision 6 System Operating Parameters 4 3 MN MBT4000 IOM Notes ...
Страница 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Страница 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Страница 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Страница 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...