MBT-4000 Multi-Band Transceiver System
Revision 6
Remote Control
MN/MBT4000.IOM
Remote Control
A–18
MN/MBT4000.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Configuration
Status
N/A
All
65 bytes
(MBT-4000)
98 bytes
(BDC),
76 bytes
(BUC)
alphanumeric
Query only.
Used to Query the configuration status of the unit
Example for MBT-4000 base:
<0001/RCS?{cr}
>0001/RCS={cr}
BF1=X {cr}
BF2=X {cr}
BT1=DN{cr}
BT2=UP{cr}
RED=0{cr}
RAM=00{cr}
MBT=N, A, or B
EXT=0{cr}{lf}
Example for BDC or BUC:
<0001A1/RCS?{cr}
>0001A1/RCS={cr}
FLO=06300{cr}
ATT=01.00{cr}
MUT=1{cr}
SLP=0.3{cr}
LCS=0{cr}
LCW=99{cr}
LFL=1{cr}
REF=XXXX{cr} (reserved for future use)
XRE=X{cr} (reserved for future use)
AFR=0{cr}{lf}
Note:
For BUC, LCS, LCW, & LFL will not be shown.
N/A
RCS?
RCS=x….x
(see description
for details of
arguments)
Redundancy
State
RED=x
MBT
1 byte,
value of 0,1,
or 2
Command or Query.
Controls redundancy state, where:
0=Off
1=Enables redundancy using single base unit
2=Enables redundancy using dual base units
Example:
RED=1
RED= (message OK)
RED? (received OK,
but invalid arguments
found)
RED* (message OK,
but not permitted in
current mode)
RED?
RED=x
(same format as
command
arguments)
Содержание MBT-4000
Страница 8: ...MBT 4000 Multi Band Transceiver System Revision 6 Table of Contents TOC 6 MN MBT4000 IOM BLANK PAGE ...
Страница 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Страница 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Страница 21: ...1 7 Notes ...
Страница 35: ...MBT 4000 Multi Band Transceiver System Revision 6 External Connectors 3 12 MN MBT4000 IOM Notes ...
Страница 38: ...MBT 4000 Multi Band Transceiver System Revision 6 System Operating Parameters 4 3 MN MBT4000 IOM Notes ...
Страница 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Страница 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Страница 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Страница 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...