150 Series
— CompX refrigerator eLock Instructions
4
8. Left click to highlight the name of the lock and then click
Edit
Lock
.
9. Verify and/or adjust all other lock parameters. (
See LockView
Instruction
Manual
for complete details.
)
10. Click
OK
when done.
Manual Method
Note: Any existing Supervisor and /or User credentials that
have already been manually programmed in the eLock will be
removed. If it is desired to keep existing credentials, choose
the Automatic Method to enroll the eLock.
1. Login to LockView.
2. Go to
Lock/User Editor
;
Lock Editor
tab and click
Add Lock
.
3. Enter the required information:
Lock Name
;
Lock Serial
Number
and
Setup Code
(supplied on green sticker set as
Setup Cd).
4. Verify and/or adjust all other lock parameters and click
OK
.
(
See
LockView Instruction Manual
for complete details on
these options
)
5. After 30 seconds, the lock will be updated in LockView. Click
Refresh
to prompt the update.
150 Series
Refrigerator eLock — Programming / Operation continued
Mount the strike
at least
4"
from
NON-HINGED EDGE
of the refrigerator.
There are two main parts of this installation: installing the strike and installing
the eLock assembly. The strike and the eLock assembly can be mounted either
with foam tape or by drilling holes and using screws. It is important to note that
mounting the strike and the eLock assembly are independent of each other. One
can be foam tape mounted, and one can be drill mounted if desired. The two do
not need to be mounted using the same method.
• VERIFY ELOCK OPERATION BEFORE BEGINNING INSTALLATION •
Install the strike
Step
1:
Foam Tape Installation
: Option A
Please note that if foam tape installation
of the strike is used, the strike will
not
be adjustable once it's put in place.
a. Clean the top refrigerator as well as the
strike with rubbing alcohol. Wait for the
alcohol to dry.
b. With a pencil, mark refrigerator 6-7/8"
from the front of the door and at least 4"
from the non-hinged edge.
Measure from this line to the front of the
cabinet (dim. “A”); cut a piece of tape
this length.
c. Remove tape backer and affix to end
of strike. The upward curve should be
on top. Apply tape to the opposite side.
Remove backer. Line up strike with line on
refrigerator; apply pressure to seal it on.
Note:
The end of the metal
strike needs to curve
up.
Option B
Option A
Drilling Installation
: Option B
a. Before drilling, verify that there are no
refrigerant lines inside the top of the
refrigerator.
b. Drill a 9/64” hole, 5-7/8” from the
edge of the front of the refrigerator and
at least 4” from the non-hinged edge of
the refrigerator.
150 Series
—
Installing the
vertical
mount refrigerator kit