Compu Pool E-Series Manual
20
a.
Language (factory setting “English”): To change the language simply press
the up or down arrow to scroll through the language options.
b.
Which Timer (factory setting “Use External”): Use the down arrow to select
“Use Internal”. Press the up arrow to select "Use Trigger". The trigger
option is selected when using a ORP input. When the ORP input is
activated the "Cell Override" LED will turn on and chlorination will start.
c.
Set Clock: When setting the clock time use the up and down arrow buttons
to select the hour and minutes. Use the left and right buttons to move the
cursor between hour and minutes. If the "Use Internal" timer option is
selected the two On and Off times then need to be set. These are the
running periods for chlorine production.
d.
Low Salt Trim: This is used to adjust the "Low Salt" level.
3. Acid Pump.
An Acid Wash System can be supplied as an additional accessory to
the E-Series Chlorinator.
Pressing the acid pump button will turn the acid pump
on or off. Before using this feature ensure that the M1 and M2 valves are closed
(refer to Figure 1 - Plumbing Diagram). The acid pump will not run if any water
flow is detected.
Also ensure that the electrolytic cells are full of water and the acid tank has been
filled to the correct levels with acid solution. If the pump is run dry damage will
occur. For further instructions see the information provided with the Acid Wash
system.
4. Cell Override.
When this button is pressed on and the timer is set to "Use
Internal" Chlorine production will commence. Press again to turn this function off.
5. Up and Down Arrows.
Pressing the Up or Down arrow will enable navigation
through the menu options.
6. Left and Right Arrows.
Pressing the Left or Right arrow will enable parameter
adjustments in the menu.
7. Output.
Pressing the up or down buttons on the home screen will change the
CHLORINE PRODUCTION output in 10% increments.
10.2 Control Panel LED Indicators
10.2.1
Polarity 1.
For single polarity units the Polarity 1 LED will always remain on. For
dual polarity units the LED will remain on for Polarity 1 and off for Polarity 2.
10.2.2
Water Flow.
The water flow warning LED will be illuminated if the flow sensor
detects no flow. Chlorine production will only occur when water flow is detected.
10.2.3
Low Salt.
The Compu Pool E-Series will automatically let you know if the salinity
concentration has fallen below acceptable levels. The warning LED will be
illuminated when salt levels fall below 2500ppm. When this warning is illuminated
add more salt to the pool to return the residual salt to the correct level of 3500ppm.