background image

 

 

                                           Compu Pool E-Series Manual

                                                 

 

20 

a. 

Language (factory setting “English”): To change the language simply press 
the up or down arrow to scroll through the language options. 

b. 

Which Timer (factory setting “Use External”):  Use the down arrow to select 
“Use  Internal”.  Press  the  up  arrow  to  select  "Use  Trigger".  The  trigger 
option  is  selected  when  using  a  ORP  input.  When  the  ORP  input  is 
activated the "Cell Override" LED will turn on and chlorination will start.  

c. 

Set Clock: When setting the clock time use the up and down arrow buttons 
to select the hour and minutes.  Use the  left and right buttons to move the 
cursor  between  hour  and  minutes.  If  the  "Use  Internal"  timer  option  is 
selected  the  two  On  and  Off  times  then  need  to  be  set.  These  are  the 
running periods for chlorine production. 

d. 

Low Salt Trim:  This is used to adjust the "Low Salt" level. 

 

3.  Acid Pump. 

An Acid Wash System can be supplied as an additional accessory to 

the  E-Series  Chlorinator.

 

Pressing  the  acid  pump  button  will  turn  the  acid  pump 

on or off. Before using  this feature ensure that the M1 and M2  valves are closed 
(refer  to  Figure  1  -  Plumbing  Diagram).  The  acid  pump  will  not  run  if  any  water 
flow is detected.

 

 Also ensure that the electrolytic cells are full of water and the acid tank has been 
filled  to  the  correct  levels  with  acid  solution.  If  the  pump  is  run  dry  damage  will 
occur.  For  further  instructions  see  the  information  provided  with  the  Acid  Wash 
system.

 

 

4.  Cell  Override. 

When  this  button  is  pressed  on  and  the  timer  is  set  to  "Use 

Internal" Chlorine production will commence. Press again to turn this function off.

 

 

5.  Up  and  Down  Arrows. 

Pressing  the  Up  or  Down  arrow  will  enable  navigation 

through the menu options.

 

 

6.  Left  and  Right  Arrows. 

Pressing  the  Left  or  Right  arrow  will  enable  parameter 

adjustments in the menu.

 

 

7.  Output. 

Pressing  the  up  or  down  buttons  on  the  home  screen  will  change  the 

CHLORINE PRODUCTION output in 10% increments.  

 

 

10.2  Control Panel LED Indicators 

10.2.1 

Polarity 1.  

For single polarity units the Polarity 1 LED will always remain on. For 

dual polarity units the LED will remain on for Polarity 1 and off for Polarity 2.

 

10.2.2 

Water Flow. 

The water flow warning LED will be illuminated if the flow sensor 

detects no flow. Chlorine production will only occur when water flow is detected.

 

10.2.3 

Low Salt. 

The Compu Pool E-Series will automatically let you know if the salinity 

concentration has fallen below acceptable levels.  The warning LED will be 
illuminated when salt levels fall below 2500ppm. When this warning is illuminated 
add more salt to the pool to return the residual salt to the correct level of 3500ppm. 

 

Содержание E-S100

Страница 1: ...Compu Pool E Series Manual 1 E Series Commercial Saltwater Chlorine Generator Owner s Manual 2012 E Series Owners Manual AU V2 docx...

Страница 2: ...S200 4 8 E S300 7 2 E S400 9 6 E S500 12 0 1 4 General 1 4 1 For indoor or protected outdoor use 1 4 2 Optimal Salt Level 3500 ppm 3 5 g L 1 4 3 Caution Over purification may be hazardous and will red...

Страница 3: ...ons in this manual Failure to do so will void the warranty 2 1 5 WARNING Heavy pool and or spa usage and higher temperatures may require higher chlorine output to maintain a proper level of free avail...

Страница 4: ...NERAL PRODUCT SPECIFICATION 2 2 0 SAFETY INSTRUCTIONS 3 3 0 INTRODUCTION 5 4 0 GETTING STARTED 5 5 0 THE CHEMISTRY INVOLVED 6 6 0 WATER CHEMISTRY 6 7 0 ADDING SALT TO POOL OR SPA 9 8 0 INSTALLATION 10...

Страница 5: ...n with the skills and experience required to install it safely and correctly Improper installation or service can result in severe electrical shock to the installer or user of the equipment or pool Pl...

Страница 6: ...t be balanced according to the following guidelines 6 1 1 With proper filtration and chemically balanced water the pool should be clear and sparkling Unbalanced water can result in scaling corrosion o...

Страница 7: ...of the pool 6 2 6 Total Dissolved Solids TDS Adding salt to pool water will raise the TDS level While this does not adversely affect the pool water chemistry or clarity the pool water professional te...

Страница 8: ...pm 6 6 Definitions 6 6 1 Algae Plant like organisms which grow in water Especially active in summer conditions where chlorine disinfectant level is too low to destroy them Algae may be green yellow br...

Страница 9: ...ell Use a salt that is at least 99 8 pure NaCl The preferred salt is an evaporated granulated food quality non iodized salt 7 2 2 Avoid using salt with anti caking agents sodium ferrocyanide also know...

Страница 10: ...used for chemical storage as this will void the warranty 8 1 2 Water leaks no matter how small should be attended to immediately If there is water in the vicinity of the chlorinator condensation may f...

Страница 11: ...four M10 screws are assembled into the rear of the electronics enclosure 03 Check that there is a small gap approximately 0 1 2mm between the screw head and the enclosure sheetmetal This will allow fo...

Страница 12: ...of the three faces with the four holes 0 40 10mm Determine which mounting option would suit the desired plumbing configuration Use strong screws or bolts to fasten the Bracket to the mounting surface...

Страница 13: ...er will need to be used 8 4 4 The flow sensor must be installed in the bypass line before the Chlorinator as shown in the plumbing diagram Figure 1 Chlorine production will only occur when the flow se...

Страница 14: ...Compu Pool E Series Manual 14 8 4 9 Figure 1 Plumbing Diagram M1 VALVE INLET FLOW SENSOR M2 VALVE OUTLET MAIN FLOW RETURN LINE FROM FILTRATION MAIN FLOW RETURN LINE TO POOL M3 VALVE...

Страница 15: ...ot provided with a pre wired cable this will need to be installed into the electronics module through the liquid tight cable gland provided The E Series unit will need to be connected to the power sou...

Страница 16: ...top left cable aperture on the Circuit Breaker compartment 06 With the cable entering the Circuit Breaker compartment Connect the active wire to Supply Active L1 Connect the neutral wire to Supply Neu...

Страница 17: ...e the cable terminal between the brass washers and nuts Using two wrenches tighten the nuts 24mm flats together firmly with a torque of approximately 60 foot pounds 80 newton meters Do not tighten the...

Страница 18: ...220VAC SFA Fuse Protected L1 to Switchmode Fans L1 From AUX Circuit Breaker 1C DFA Fuse Protected L1 to Door Fan L1 From AUX Circuit Breaker 1C TFA Fuse Protected L1 to Transformer L1 From AUX Circuit...

Страница 19: ...re tight 9 1 7 Cell Module locking collar is tight 9 1 8 Circuit breakers are working correctly 9 1 9 Sufficient salt has previously been added and fully dissolved into pool water 10 0 USING THE CONTR...

Страница 20: ...are full of water and the acid tank has been filled to the correct levels with acid solution If the pump is run dry damage will occur For further instructions see the information provided with the Aci...

Страница 21: ...ural result of the electrolytic process which creates chlorine calcium build up is attracted to the titanium plates in the cell The cell requires regular cleaning to ensure that build up does not caus...

Страница 22: ...en the titanium blades inside the Electrolytic Cell have reached the end of their lifespan replacements are available so that the whole system does not have to be removed Replacements are easily switc...

Страница 23: ...cility or returned for repair to our facility at no cost Compu Pool reserves the right to determine whether or not a part will be replaced with a new or refurbished part or repaired 12 2 Void Warranty...

Страница 24: ...se complete the information below at time of installation and retain in the event you need to file a warranty claim Model Number Voltage Electronics Module Serial Number Cell Module Serial Number s Pu...

Отзывы: