Compool

Cp3810 AQUATIC CONTROL SYSTEM

Installation & Operating Instructions

04/23/97
941-1100

Содержание Cp3810

Страница 1: ...Compool Cp3810 AQUATIC CONTROL SYSTEM Installation Operating Instructions 04 23 97 941 1100...

Страница 2: ......

Страница 3: ...Circuit Board 12 Low Voltage Cables 13 Gas Heater Connections 13 Water Temperature Sensor 14 Freeze Temperature Sensor 14 Control Panel 15 Modular Crimping Tool 16 System Options 17 Spa side Remote 1...

Страница 4: ...ming 28 Programming 29 Programming additional Run Times 29 Programming a Time out 29 Programming a Once only 30 Canceling Programs 30 Setting the Time of Day 30 Remote Control key 30 Calibration 31 Po...

Страница 5: ...unless they are closely supervised at all times Water in excess of 100 degrees Fahrenheit may be hazardous to your health A terminal bar marked for equipment ground only is located inside the high vol...

Страница 6: ...4 Compool Cp3810 Introduction Package Contents The CP3810 S system includes the following components CP 3810 Control Panel w cable 1 qty LX 3810 Power Center 1 qty SNS KIT2 Sensor Kit 1 qty...

Страница 7: ...5 Compool Cp3810 The CP3810 SL system includes the following components CP 3810 Control Panel w cable 1 qty LX 3810L Power Center 1 qty SNS KIT2 Sensor Kit 1 qty...

Страница 8: ...SOLAR PUMP VACUUM RELIEF WATER SENSOR SKIMMER FILTER PUMP FILTER MAIN DRAIN HW 5B WATERFALL POOL LIGHT POOL 7 3 8 5 FREEZE SENSOR CONTROL PANEL POWER CENTER SOLAR SENSOR HEATER CVA 24 VACUUM RELIEF W...

Страница 9: ...low draining of panels This prevents damage from overheating water Install drain valve at solar feed line and connect to the pool fill line 5 Plumb solar feed and return lines between the filter and h...

Страница 10: ...the equipment Provide power from the Main panel located at the house to Power Center Power Center without built in Sub panel At the equipment pad mount a 100 amp electrical circuit breaker panel Sub p...

Страница 11: ...ipment Water Sensor Solar Sensor Sensor Status Auto Auto Service Press Filter key 2 times quickly Filter Pump On Press Filter key 3 times quickly Filter Pump Off To cancel The 3 hour override can be c...

Страница 12: ...LOAD 1 LOAD 2 R6 LINE 1 LINE 2 LOAD 1 LOAD 2 R7 HIGH VOLTAGE RELAYS FULL LOAD 20AMP LOCKED ROTOR 60AMP Lx3810 SUB PANEL Filter Pump Heater 6 5 4 3 2 1 P Solar Auto Service IMPORTANT Switch back to Au...

Страница 13: ...2 R2 LINE 1 LINE 2 LOAD 1 LOAD 2 R3 LINE 1 LINE 2 LOAD 1 LOAD 2 R4 LINE 1 LINE 2 LOAD 1 LOAD 2 R5 LINE 1 LINE 2 LOAD 1 LOAD 2 R6 LINE 1 LINE 2 LOAD 1 LOAD 2 R7 HIGH VOLTAGE RELAYS FULL LOAD 20AMP LOCK...

Страница 14: ...OT SHORT PINS OF RELAY SOCKETS RELAY CONNECTIONS 944 1099 GND HLMP HBST FLTR REM1 REM2 REM3 REM4 REM5 REM6 TRANSFORMER CONNECTIONS AUXILIARY VALVE ACTUATORS AUX VALVE ACTUATOR 18 10 24 PART PC LX3810...

Страница 15: ...Power Center Caution Do not install low voltage and high voltage wires in the same conduit Use conduit when cable goes underground Gas Heater Connections The diagram above shows how to wire a gas heat...

Страница 16: ...ff stripped ends of cable Insert the 2 wires to be connected into the connector and squeeze the connector with a pair of pliers Two extra connectors are included Caution Do not strip wires 6 At the Po...

Страница 17: ...location inside the house or other weather protected area to mount the Control Panel The Control Panel should be installed at or below eye level 2 Remove backplate from Control Panel Position backplat...

Страница 18: ...ng from an electrical supply store verify it is designed to crimp 6 position connectors To install the modular connectors 1 Use stripper to remove cable jacket 2 Insert modular connector into crimper...

Страница 19: ...c pipe with pvc cement so that the red button will be on top 5 At the Power Center connect Spa side Remote wires to appropriate screw terminals located at bottom of the of the circuit board 6 Connect...

Страница 20: ...a coupler model 6COND DUAL is required Valve Actuators Valve Actuators come with 15 feet of cable If this distance is not long enough it is possible to splice in additional wire to lengthen cable Use...

Страница 21: ...ter circuit board at the appropriate relay socket FLTR AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 EHTR SOL PUMP 2SPD FLRCL 6 The D I P switch located at the upper left side of Valve Module allows combining the ope...

Страница 22: ...color coding of wires 5 Turn on SYST SOLR configuration switch located at the bottom of the Power Center circuit board 6 Connect solar Valve Actuator cord into AUX VLV socket at the Power Center circ...

Страница 23: ...an be installed These relays are controlled by Equipment keys 3 and 4 Each relay can switch a maximum of 1000 watts To install the Dimmer Relay 1 Install the Dimmer Relay s into high the voltage compa...

Страница 24: ...ump is on Additional parts required one Valve Actuator model CVA 24T and one 3 port valve model PTV 2T To install the Floor Cleaner Valve 1 Install Valve Actuator onto Floor Cleaner valve 2 Plug valve...

Страница 25: ...nterlocks Cleaner must be installed on AUX1 FDEL Activate filter delay heater cool down SYST System System settings are used to configure the following equipment SOLR Activate solar system HTPMP Activ...

Страница 26: ...position If it is 180 degrees out of phase flip the toggle switch on the rear of Valve Actuator to reverse phase ON1 ON2 5 Check Sensor Status lights If a light is on check appropriate sensor wiring a...

Страница 27: ...s needed Equipment Keys Equipment keys activate the spa or pool and up to 6 additional items Each key can be custom labeled for your specific application To turn equipment on or off press the appropri...

Страница 28: ...filter pump on for an additional 10 minutes to allow the heater to cool down During this cool down cycle and icon on the display will indicate DELAY Some heaters do not require a cool down period so t...

Страница 29: ...or added convenience whenever the H key Spa High or Pool High is manually activated from either the Control Panel or the Spa side Remote the Spa Heat Source Lamp will automatically switch to Heater Tu...

Страница 30: ...ey Located behind the right door of the Control Panel is the Temp Display key Press this key to select Fahrenheit or Celsius temperature display Programming Behind the right door of the Control Panel...

Страница 31: ...the RUN TIME 6 Press the Program key to end Programming additional Run Times It is possible to program up to four separate START TIME and RUN TIME s for each equipment key Follow the previous example...

Страница 32: ...ow a row of blinking icons located immediately above the eight Equipment keys 2 Press and hold down the Cancel key for 5 seconds After 5 seconds a continuous alarm will sound until you release the Can...

Страница 33: ...ess the Spa Heat Source key 3 Enter correct pool temperature and press Spa Heat Source key 4 Enter correct solar temperature and press Spa Heat Source key 5 Enter correct air temperature and press Spa...

Страница 34: ...s for calibrating the temperature sensors Water Sensor Let the pool run for 5 minutes to allow water temperature sensor to accurately pickup current pool water temperature Solar Sensor Put a thermomet...

Страница 35: ...the following modes Auto Control Panel and Spa side Remote are enabled Power Center keys are disabled Service Power Center keys are enabled Control Panel and Spa side Remote are disabled A blinking A...

Страница 36: ...s the P key Filter Pump 3 times quickly The Auto mode Status Lamp will begin to blink and the Filter Pump Status Lamp will not be illuminated during the 3 Hour cycle Sensor Status If there is a fault...

Страница 37: ...he light will blink during the 5 minute cycle to indicate that the spa is being heated If you wish to turn the heater off at any time during this 5 minute cycle press the Heat Boost button again The l...

Страница 38: ...peed filter pump can be switched to high speed under the following conditions High is on Heater is on Aux1 is on Solar is on Note When the 2 speed filter is turned on it will start in high speed and a...

Страница 39: ...Sensor model TS 5L Display shows Err 4 If the Control Panel is not able to communicate with the Power Center the display will show Err 4 Check communication cable and connections Use test cable provi...

Страница 40: ...anel Check circuit breakers in the Sub panel and Power Center Check communication cable Clock lost time after power failure Replace battery located on Power Center circuit board System not responding...

Страница 41: ...39 Compool Cp 3810...

Страница 42: ...mps 26 Fahrenheit Celsius key 28 Floor Cleaner Valve 22 FREEZE 23 Freeze Protection 36 Freeze Temperature Sensor 14 Gas Heater Connections 13 Heat Pump or Electric Heater 19 Heater Protection 26 HI SP...

Страница 43: ...0 Solar Booster Pump Control 20 Solar Heating 20 Spa side Heat Boost 34 Spa side Remote 17 Spa side Remote 34 SPEC FUNCT Special Functions 23 SYST System 23 System Options 17 System Options 36 System...