Technical features 

 ________________________________________________________________________ 

Installation

  ______________________________________________________________________________________________ 

Connection to the ball valve

  _______________________________________________________________________________________________ 

Electrical connections

 __________________________________________________________________________ 

Reference positions 

 __________________________________________________________________________ 

Emergency manual opening

 __________________________________________________________________________ 

Auxiliary microswitch signals

 __________________________________________________________________________ 

Position feedback

 __________________________________________________________________________ 

Operation 

 __________________________________________________________________________ 

Fail Safe (optional)

 __________________________________________________________________________ 

Motor anti-overheating (optional upon request) 

 __________________________________________________________________________ 

Monitoring 

 __________________________________________________________________________ 

Wi-Fi communication (optional)

 __________________________________________________________________________ 

Serial RS458 communication - Modbus (optional)

 __________________________________________________________________________ 

Operating anomalies 

 __________________________________________________________________________ 

General warranty conditions 

 __________________________________________________________________________

NOTICES

 

Read the warnings contained in the manual carefully, since they provide important information about safe installation, use and maintenance. Installation and maintenance shall be performed in accordance with the 
relevant regulations and the manufacturer's instructions. In case of failure and/or malfunctioning of the appliance, do not attempt any repair or direct servicing. Always contact qualified personnel, as provided by 
law. Only qualified technicians are allowed to carry out any repair operation. Failure to comply with the provisions listed above may compromise the safety of the appliance. 
 

 

TECHNICAL FEATURES

TABLE OF CONTENTS

2

 

 

3

 

 

4

 

6

 

6

 

7

 

7

 

7

 

12

 

13

     

13

 

14

 

16

 

18

 

18

 

 
 

DANGER:

DANGER:

12Vdc • 24Vdc • 24V 50/60 Hz • 100...    240V 50/60 Hz

10W

25W

25W

2W

3W

3W

3W

5W

5W

11Nm

22Nm

40Nm

Diamant  

SMART 

PRO

Compact  

SMART 

PRO

Universal  

SMART 

PRO

Power supply 

Maximum power consumption during operation 

Power consumption during standby 

Heating resistance power 

Supply cable 

Signal cable 

Auxiliary micro output 

Rated torque 

Control type ON/FF 

Proportional positioning signal 

Position signal dead band 

Position signal impedance 

Positioning feedback 

Maximum position feedback current 

Positioning accuracy 

Motor rotation direction 

Manual override 

Rotation angle 

Angular positioning correction 

Operating time (         90°) 

Maximum noise 

Protection degree 

Connection to the valve 

Accumulator 

Emergency position 

Fail safe operating time (         90°) 

Minimum charging time 

Maximum power consumption 
 

4 x 0,5 mm^2 (AWG 20) - Length 1m 

12 x 0,2 mm^2 (AWG 24) - Length 1m 

max 30Vdc - 0,1 A

2-point • 3-point • 0°- 45° - 90° • 0°- 90° - 180° 

0-10V • 2-10V • 0-20 mA • 4-20 mA • PWM1 • PWM2 

Adjustable: 1% • 3% • 5% 

100k

Ω

 

(0-10V / 2-10V) •

 

500k

Ω

 

(0-20 mA / 4-20 mA) • 133k

Ω

 

(PWM) 

2-10Vdc 

40 mA 

+/- 5% 

Reversible 

Release lever and button 

90° • 180° 

With Modbus or Wi-Fi interface

DIAMANT SMART PRO / COMPACT SMART PRO / UNIVERSAL SMART PRO

ELECTRICAL DA

TA

ELECTRICAL DA

TA

FAIL SAFE

15s* • 30s • 60s • 120s

15s* • 30s • 60s • 120s

30s • 60s • 120s

45 dB (A)

60 dB (A)

Supercapacitors 

Programmable opening / closing / intermediate

IP67

65 dB (A)

0,6 W

3 W

3 W

20s

26s

30s **

15 min (90°) • 60 min (180°)

9 min (90°) • 18 min (180°)

50 min (90°)

Comparato • ISO 5211 F03/F05

 ISO 5211 F03/F05

 ISO 5211 F05/F07

*        time not available with 12Vdc power supply. 
**      for the 180° rotation angle fail safe operation, please contact our technical office.

Electrical hazard!

 The unit contains high-voltage equipment.

Scalding hazard! 

Even in normal operation conditions, the unit can reach very high temperatures which may cause scalds.

Содержание Compact SMART PRO

Страница 1: ...VER 3 21...

Страница 2: ...cturer s instructions In case of failure and or malfunctioning of the appliance do not attempt any repair or direct servicing Always contact qualified personnel as provided by law Only qualified techn...

Страница 3: ...1 None 10 C 50 C 40 C 80 C RH max 95 no condensa None CE WI FI MODBUS SAFETY 3 COMPARA TO NELLO SRL DIAMANT SMART PRO COMPACT SMART PRO UNIVERSAL SMART PRO in case of environments with a high density...

Страница 4: ...SMART PRO with COMPARATO connection DIAMANT SMART PRO with ISO 5211 connection COMPACT SMART PRO UNIVERSAL SMART PRO ELECTRICAL CONNECTIONS ALL UNCONNECTED WIRE TERMINALS MUST BE ISOLATED Only for MOD...

Страница 5: ...pply it is possible to make the electrical connection according to the following scheme The actuator has a double half wave power supply stage therefore it cannot be used with other devices with singl...

Страница 6: ...PENING position Press the release button A and simultaneously rotate the lever B 90 COUNTERCLOCKWISE in order to move the actuator in the CLOSED position Actuator in CLOSING position Press the release...

Страница 7: ...V proportional to the angular position reached by the actuator The feedback has monitoring purposes for example it can be connected to a display If the value is 0V the actuator is in a fault condition...

Страница 8: ...llows to bring the actuator in the intermediate position 45 or 90 angle according to the 90 or 180 operating angle combining the power supply phases Cable A BLUE BROWN and BLACK wire Logic states tabl...

Страница 9: ...received signal PWM1 PWM2 POWER SUPPLY Power supply The power supply selection allows the system to automatically set the correct control parameters of the stepper motor For the 12V 24V AC DC version...

Страница 10: ...NG TIME s POWER SUPPLY 12V dc 24V ac dc 100 240V 50 60Hz 15 NO YES YES 30 YES YES YES 60 YES YES YES 120 YES YES YES DIAMANT SMART PRO OPERATING TIME s POWER SUPPLY 12V dc 24V ac dc 100 240V 50 60Hz 1...

Страница 11: ...10V feedback signal and the positioning shown on the Wi Fi interface screen are automatically scaled according to the new opening and closing angular positioning values CLOSING POSITION CORRECTION CL...

Страница 12: ...ans of a temperature reading you can activate and set the setpoint temperature between 5 C and 30 C or deactivate it Heating resistance activation Heater active YES active resistance NO non active res...

Страница 13: ...eached inside the actuator and lets the system manage the heating resistance ELECTRIC MOTOR TEMPERATURE Motor temp C Motor anti overheating feature available upon request For further information pleas...

Страница 14: ...11235813 IP address 192 168 4 1 If the device used for the connection does not automatically open the configuration screen open a browser and type the IP address written on the actuator cover IP addre...

Страница 15: ...ICH ARE NOT WRITTEN PRESSING THE WRITE KEY WILL NOT BE UPDATED READ key reads all the parameters and returns the updated values WRITE key writes all the edited parameters ADVANCED MODE key access to t...

Страница 16: ...ard EIA RS 485 half duplex Baud rate 19200 Baud s N bit 8 Stop bit 1 Parity None SLAVE ADDRESS FUNCTION CODE VALUE CRC WORD SLAVE ADDRESS FUNCTION CODE VALUE CRC WORD PARAMETER DESCRIPTION SLAVE ADDRE...

Страница 17: ...17 COMPARA TO NELLO SRL ADDRESS TABLE DIAMANT SMART PRO COMPACT SMART PRO UNIVERSAL SMART PRO...

Страница 18: ...during the installation wrong incomplete or missing assembling wiring setting electrostatic discharge electric discharge conducted induced because of lightning or other phenomena not ascribable to the...

Страница 19: ...19 COMPARA TO NELLO SRL comparato com DIAMANT SMART PRO COMPACT SMART PRO UNIVERSAL SMART PRO...

Страница 20: ......

Отзывы: