background image

VER. 3.21

Содержание Compact SMART PRO

Страница 1: ...VER 3 21...

Страница 2: ...cturer s instructions In case of failure and or malfunctioning of the appliance do not attempt any repair or direct servicing Always contact qualified personnel as provided by law Only qualified techn...

Страница 3: ...1 None 10 C 50 C 40 C 80 C RH max 95 no condensa None CE WI FI MODBUS SAFETY 3 COMPARA TO NELLO SRL DIAMANT SMART PRO COMPACT SMART PRO UNIVERSAL SMART PRO in case of environments with a high density...

Страница 4: ...SMART PRO with COMPARATO connection DIAMANT SMART PRO with ISO 5211 connection COMPACT SMART PRO UNIVERSAL SMART PRO ELECTRICAL CONNECTIONS ALL UNCONNECTED WIRE TERMINALS MUST BE ISOLATED Only for MOD...

Страница 5: ...pply it is possible to make the electrical connection according to the following scheme The actuator has a double half wave power supply stage therefore it cannot be used with other devices with singl...

Страница 6: ...PENING position Press the release button A and simultaneously rotate the lever B 90 COUNTERCLOCKWISE in order to move the actuator in the CLOSED position Actuator in CLOSING position Press the release...

Страница 7: ...V proportional to the angular position reached by the actuator The feedback has monitoring purposes for example it can be connected to a display If the value is 0V the actuator is in a fault condition...

Страница 8: ...llows to bring the actuator in the intermediate position 45 or 90 angle according to the 90 or 180 operating angle combining the power supply phases Cable A BLUE BROWN and BLACK wire Logic states tabl...

Страница 9: ...received signal PWM1 PWM2 POWER SUPPLY Power supply The power supply selection allows the system to automatically set the correct control parameters of the stepper motor For the 12V 24V AC DC version...

Страница 10: ...NG TIME s POWER SUPPLY 12V dc 24V ac dc 100 240V 50 60Hz 15 NO YES YES 30 YES YES YES 60 YES YES YES 120 YES YES YES DIAMANT SMART PRO OPERATING TIME s POWER SUPPLY 12V dc 24V ac dc 100 240V 50 60Hz 1...

Страница 11: ...10V feedback signal and the positioning shown on the Wi Fi interface screen are automatically scaled according to the new opening and closing angular positioning values CLOSING POSITION CORRECTION CL...

Страница 12: ...ans of a temperature reading you can activate and set the setpoint temperature between 5 C and 30 C or deactivate it Heating resistance activation Heater active YES active resistance NO non active res...

Страница 13: ...eached inside the actuator and lets the system manage the heating resistance ELECTRIC MOTOR TEMPERATURE Motor temp C Motor anti overheating feature available upon request For further information pleas...

Страница 14: ...11235813 IP address 192 168 4 1 If the device used for the connection does not automatically open the configuration screen open a browser and type the IP address written on the actuator cover IP addre...

Страница 15: ...ICH ARE NOT WRITTEN PRESSING THE WRITE KEY WILL NOT BE UPDATED READ key reads all the parameters and returns the updated values WRITE key writes all the edited parameters ADVANCED MODE key access to t...

Страница 16: ...ard EIA RS 485 half duplex Baud rate 19200 Baud s N bit 8 Stop bit 1 Parity None SLAVE ADDRESS FUNCTION CODE VALUE CRC WORD SLAVE ADDRESS FUNCTION CODE VALUE CRC WORD PARAMETER DESCRIPTION SLAVE ADDRE...

Страница 17: ...17 COMPARA TO NELLO SRL ADDRESS TABLE DIAMANT SMART PRO COMPACT SMART PRO UNIVERSAL SMART PRO...

Страница 18: ...during the installation wrong incomplete or missing assembling wiring setting electrostatic discharge electric discharge conducted induced because of lightning or other phenomena not ascribable to the...

Страница 19: ...19 COMPARA TO NELLO SRL comparato com DIAMANT SMART PRO COMPACT SMART PRO UNIVERSAL SMART PRO...

Страница 20: ......

Отзывы: