6-20
Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide
Compaq Confidential – Need to Know Required
Writer: Bryan Hicks Project: Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide Comments:
Part Number: 380362-003 File Name: g-ch6 Troubleshooting the Compaq ProLiant Clusters HAF100 and HAF200.doc Last Saved On: 8/24/00 12:04
PM
Table 6-8
Error Messages
continued
Message
Description
Action
Logical disk could not be
reached in the following
RA4x00: <xxxxxx>.
Redundancy Manager found an
array with no drives in it. This
could be caused by a damaged
array or a bad connection.
Check the array and all
connections.
The lock could not be set.
The array controller board is in
an unknown state that caused a
failed connection to the array
controller.
No action needed to view the
data.
To configure the data, check the
array controller and all physical
connections.
The loop has been locked by
another application. Redundancy
Manager is running in Read Only
mode.
Another application has issued a
lock management command to
an array controller. The lock
management command only
allows viewing the data.
No action needed to view the
data.
To configure the data, close the
other application to unlock the
array controller. If the lock has
expired, Redundancy Manager
allows overriding the lock and
taking control of the array
controller.
There was an error attempting
to shut down Windows NT.
Please close all applications and
shut down now.
An error occurred while shutting
down Windows NTS/E.
Close all applications and shut
down the computer
immediately.
A version of the Compaq Fibre
Channel Host Adapter SCSI
Miniport Driver (
CPQFCALM.SYS
)
is being used that does not
support redundancy. The
minimum version for
redundancy support is VX.X. The
current version is VX.Z.
Redundancy has been disabled.
This message informs you that
the version of
CPQFCALM.SYS
doesn’t support redundancy.
Make sure you have the correct
version of
CPQFCALM.SYS
.
Содержание ProLiant Clusters HA/F100
Страница 8: ......