line failure
1109 - 06
Serial Clock Test, data
line failure
------------------------------------------------------------------------------
Error
Error
Required
Code
Description
Action
------------------------------------------------------------------------------
Fixed Disk Drive
17yy - xx
------------------------------------------------------------------------------
1700 - xx
Fixed disk drive ID drive
The following steps apply to error
test type
codes 1700 - xx through 1716 - 59:
1701 - xx
Fixed disk drive format
1.
Check the fixed disk drive
test
controller board for the
proper switch setting
1702 - xx
Fixed disk drive read test
(see Chapter 8). *
2.
Replace the fixed disk drive
1703 - xx
Fixed disk drive write/
signal and power cables.
read/compare test
3.
Replace the fixed disk drive
controller board. *
1704 - xx
Fixed disk drive random
4.
Replace the fixed disk drive
seek test
assembly.
5.
Replace the system board.
1705 - xx
Fixed disk drive controller
test
* 286 based COMPAQ Personal
Computers only
1706 - xx
Fixed disk drive ready test
1707 - xx
Fixed disk drive
recalibrate test
1708 - xx
Fixed disk drive format bad
track test
1709 - xx
Fixed disk drive reset
controller test
1710 - xx
Fixed disk drive park head
test
1714 - xx
Fixed disk drive file write
test
------------------------------------------------------------------------------
Error
Error
Required
Code
Description
Action
------------------------------------------------------------------------------
Fixed Disk Drive
17yy - xx
------------------------------------------------------------------------------
1715 - xx
Fixed disk drive head select
The following steps apply to error
test
codes 1700 - xx through 1716 - 59:
1716 - xx
Fixed disk drive conditional
1.
Check the fixed disk drive
format test
controller board for the
proper switch setting
1716 - 01
Exceeded maximum soft error
(see Chapter 8). *
limit
2.
Replace the fixed disk drive
signal and power cables.