40
U4
U13
U22
U31
U40
U49
U58
U67
20
U5
U14
U23
U32
U41
U50
U59
U68
10
U6
U15
U24
U33
U42
U51
U60
U69
08
U7
U16
U25
U34
U43
U52
U61
U70
04
U8
U17
U26
U35
U44
U53
U62
U71
02
U9
U18
U27
U36
U45
U54
U63
U72
01
U10
U19
U28
U37
U46
U55
U64
U73
00
U11
U20
U29
U38
U47
U56
U65
U74
==============================================================================
COMPAQ Portable and COMPAQ PLUS Memory Error Codes
Memory error codes for the COMPAQ Portable and COMPAQ PLUS Personal Computers
will appear in an "XXYY 201" format.
XX - Denotes the beginning address of the error code (or the bank in which the
error occurred)
YY - Denotes the failed bit
Once all corrections have been completed and all boards have been reinstalled
in the system, begin the problem isolation procedure again to verify proper
operation of the CPU/memory subsystem.
Table 5.4-4.
COMPAQ Portable and COMPAQ PLUS System Board Memory
==============================================================================
Error
Failure
Location of
Code
Description
Failed Chip
Required Action
------------------------------------------------------------------------------
(XXYY 201)
------------------------------------------------------------------------------
0000 201
Bank 0, Parity
U39
Replace System Board
0001 201
Bank 0, Data Bit 0
U97 or U53 *
Replace System Board
0002 201
Bank 0, Data Bit 1
U87 or U53 *
Replace System Board
0004 201
Bank 0, Data Bit 2
U80 or U53 *
Replace System Board
0008 201
Bank 0, Data Bit 3
U74 or U53 *
Replace System Board
0010 201
Bank 0, Data Bit 4
U70 or U45 *
Replace System Board
0020 201
Bank 0, Data Bit 5
U63 or U45 *
Replace System Board
0040 201
Bank 0, Data Bit 6
U54 or U45 *
Replace System Board
0080 201
Bank 0, Data Bit 7
U46 or U45 *
Replace System Board