and for Phase V:
NCL SHOW NODE
host MOP Client gateway ALL
If you receive the following message,
No information available
then this particular system has not been set up as a load host. Define
the system as a load host following the instructions in DECnet SNA
Gateway-ST Installation.
8.
If this system is a load host, check the following items in the display
information:
DECnet node address
Service circuit
Hardware address
Load file specification
The service circuit name must match the name of the circuit on the load
host to which the Gateway-ST is connected.
The hardware address (twelve hexadecimal digits) should match the
Ethernet address of the Gateway-ST node. You can find the DEC
MicroServer Ethernet hardware address on the label on the back of the
DEC MicroServer.
Check that the load file specification is
SYS$COMMON:[SNA$CSV]SNACSTnnn.SYS
where nnn is the product version number.
Correct any errors you find. Use the DIRECTORY command to check that
the Gateway-ST load file exists.
Try to load the Gateway-ST software.
9.
Check the state of the line connecting the load host to the Gateway-ST by
issuing the NCP command:
NCP> SHOW LINE
line-id STATUS
If the line state is OFF, change the state to ON with the following NCP
command:
NCP> SET LINE
line-id STATE ON
The value of the line-id must be the same as the value of the service circuit
previously displayed.
1–18 Solving DECnet SNA Gateway for Synchronous Transport Problems