4-10
XP900 Console Reference
4.8
Remote Halt (In/Out)
You can issue a halt to a monitored system from the RMC using
console monitor commands. Under OpenVMS and Tru64 UNIX,
the system will halt. Under Windows NT, the command will be
ignored.
Figure 4–5 Halt/Reset Jumper
PK0246c
Setting for
OpenVMS
& Tru64 UNIX
Setting for
Windows NT
1
1
The RMC halt in command can be issued remotely to halt the system.
The RMC halt out command can be issued to deassert the halt.
These commands have the same function as the Halt button on the control
panel (see Figure 4–6) for OpenVMS and Tru64 Unix. The Halt button under
Windows NT operates differently because the Halt/Reset jumper is set
differently (see Figure 4–5).