Remote Management Console
4-7
4.6
Status Monitoring
Use the RMC status command to check the current state of the
system’s sensors as well as the current escape sequence and
alarm information.
PLATFORM STATUS
Firmware Revision: V1.0
System Power: ON
RMC Halt: Deasserted
RMC Power Control: ON
Power Supply: OK
System Fans: OK CPU Fan: OK
Temperature: 31.0°C (warnings at 55.0°C, power-off at 60.0°C)
Escape Sequence: ^[^[RMC
Remote Access: Disabled
RMC Password: set
Alert Enable: Disabled
Alert Pending: YES
Init String: AT&F0E0V0S0=2
Dial String: ATXDT8,18007598888
Alert String: ,,,,,,,1066278#,,,,,,,,1#,,,,30140#;
Com1_mode: SNOOP
Last Alert: AC Loss
Watchdog Timer: 00 seconds
Autoreboot: OFF
Logout Timer: 20 minutes
User String:
Table 4–2 Status Command Fields
Field
Meaning
Firmware Revision
Revision of RMC firmware on the microcontroller.
System Power
On = System is on.
Off = System is off.
RMC Halt
Asserted = System has been halted.
Deasserted = Halt has been released from halt.
Continued on next page.