Troubleshooting
2-9
2.3
Service Tools and Utilities
This section lists some of the tools and utilities available for acceptance
testing and diagnosis and gives recommendations for their use.
2.3.1
Error Handling/Logging Tools (Compaq Analyze)
The Tru64 UNIX, OpenVMS, and Microsoft Windows NT operating systems
provide fault management error detection, handling, notification, and logging.
The primary tool for error handling is Compaq Analyze, a fault analysis utility
designed to analyze both single and multiple error/fault events. Compaq
Analyze uses error/fault data sources other than the traditional binary error log.
See Chapter 5.
2.3.2
Loopback Tests
Internal and external loopback tests are used to test the components on the I/O
connector assembly (“junk I/O”) and to test Ethernet cards. The loopback tests
are a subset of the SRM diagnostics.
Use loopback tests to isolate problems with the COM2 serial port, the parallel
port, and Ethernet controllers. See the test command in Chapter 4 for
instructions on performing loopback tests.
2.3.3
SRM Console Commands
SRM console commands are used on systems running Tru64 UNIX or OpenVMS
to set and examine environment variables and device parameters. For example,
the show configuration and show device commands are used to examine the
configuration, and the set envar command is used to set environment
variables.
SRM commands are also used to invoke ROM-based diagnostics and to run
native exercisers. For example, the test and sys_exer commands are used to
test the system.
See Chapter 6 for information on configuration-related console commands and
environment variables. See Chapter 4 for information on running console
exercisers. See Appendix A for a list of console commands used most often on
ES40 systems.
Содержание AlphaServer ES40
Страница 4: ......
Страница 16: ......
Страница 20: ......
Страница 68: ......
Страница 104: ......
Страница 162: ......
Страница 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Страница 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Страница 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Страница 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Страница 194: ......
Страница 280: ......
Страница 292: ...8 12 Compaq AlphaServer ES40 Service Guide Figure 8 4 Enclosure Panel Removal Pedestal 1 2 PK0234 ...
Страница 298: ...8 18 Compaq AlphaServer ES40 Service Guide Figure 8 7 Covers on the System Chassis Tower PK0216 5 4 3 1 2 2 2 1 ...
Страница 299: ...FRU Removal and Replacement 8 19 Figure 8 8 Covers on the System Chassis Pedestal Rack PK0215 1 4 5 3 2 1 2 ...
Страница 300: ...8 20 Compaq AlphaServer ES40 Service Guide 8 5 Power Supply Figure 8 9 Removing a Power Supply 5 4 3 2 PK0232a 1 ...
Страница 302: ...8 22 Compaq AlphaServer ES40 Service Guide 8 6 Fans Figure 8 10 Replacing Fans Unlock Lock 5 6 1 2 3 4 PK0208 ...
Страница 304: ...8 24 Compaq AlphaServer ES40 Service Guide 8 7 Hard Disk Drives Figure 8 11 Removing a Hard Drive PK0938a 1 2 ...
Страница 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Страница 314: ...8 34 Compaq AlphaServer ES40 Service Guide 8 11 OCP Assembly Figure 8 16 Removing the OCP Assembly 1 2 PK0282 ...
Страница 318: ...8 38 Compaq AlphaServer ES40 Service Guide 8 13 Floppy Drive Figure 8 18 Removing the Floppy Drive 1 2 3 4 4 5 PK0281 ...
Страница 324: ...8 44 Compaq AlphaServer ES40 Service Guide Figure 8 21 Removing the PCI Backplane PK0280 3 1 2 2 4 1 ...
Страница 332: ......
Страница 336: ......
Страница 358: ......
Страница 444: ......