5-14
Compaq AlphaServer ES40 Service Guide
5.3
Machine Checks/Interrupts
The exceptions that result from hardware system errors are called
machine checks/interrupts. They occur when a system error is detected
during the processing of a data request.
During the error-handling process, errors are first handled by the appropriate
PALcode error routine and then by the associated operating system error
handler. PALcode transfers control to the operating system through the PAL
handler.
Table 5–2 lists the machine checks/interrupts that are related to error events.
The designations — 630, 670, 620, 660, and 680 — indicate a system control
block (SCB) offset to the fatal system error handler for Tru64 UNIX and
OpenVMS. Windows NT does not use SCB offsets, but instead uses a self-
maintained interrupt dispatch table (IDT).
Table 5–2 Machine Checks/Interrupts
Error Type
Error Descriptions
CPU Correctable Error (630)
Generic Alpha 21264 (EV6)
correctable errors.
B-cache probe hit single-bit ECC error
D-cache tag parity error on issue
I-cache tag or data parity error
D-cache victim single-bit ECC error
B-cache single-bit ECC fill error to I-stream or
D-stream
Memory single-bit ECC fill error to I-stream
or D-stream
CPU Uncorrectable Error
(670)
Fatal microprocessor machine
check errors that result in a
system crash.
PAL detected bugcheck error
Operating system detected bugcheck error
EV6 detected second D-cache store EEC error
EV6 detected D-cache tag parity error in
pipeline 0 or 1
EV6 detected duplicate D-cache tag parity
error
EV6 detected double-bit ECC memory fill
error
EV6 detected double-bit probe hit EEC error
EV6 detected B-cache tag parity error
Содержание AlphaServer ES40
Страница 4: ......
Страница 16: ......
Страница 20: ......
Страница 68: ......
Страница 104: ......
Страница 162: ......
Страница 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Страница 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Страница 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Страница 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Страница 194: ......
Страница 280: ......
Страница 292: ...8 12 Compaq AlphaServer ES40 Service Guide Figure 8 4 Enclosure Panel Removal Pedestal 1 2 PK0234 ...
Страница 298: ...8 18 Compaq AlphaServer ES40 Service Guide Figure 8 7 Covers on the System Chassis Tower PK0216 5 4 3 1 2 2 2 1 ...
Страница 299: ...FRU Removal and Replacement 8 19 Figure 8 8 Covers on the System Chassis Pedestal Rack PK0215 1 4 5 3 2 1 2 ...
Страница 300: ...8 20 Compaq AlphaServer ES40 Service Guide 8 5 Power Supply Figure 8 9 Removing a Power Supply 5 4 3 2 PK0232a 1 ...
Страница 302: ...8 22 Compaq AlphaServer ES40 Service Guide 8 6 Fans Figure 8 10 Replacing Fans Unlock Lock 5 6 1 2 3 4 PK0208 ...
Страница 304: ...8 24 Compaq AlphaServer ES40 Service Guide 8 7 Hard Disk Drives Figure 8 11 Removing a Hard Drive PK0938a 1 2 ...
Страница 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Страница 314: ...8 34 Compaq AlphaServer ES40 Service Guide 8 11 OCP Assembly Figure 8 16 Removing the OCP Assembly 1 2 PK0282 ...
Страница 318: ...8 38 Compaq AlphaServer ES40 Service Guide 8 13 Floppy Drive Figure 8 18 Removing the Floppy Drive 1 2 3 4 4 5 PK0281 ...
Страница 324: ...8 44 Compaq AlphaServer ES40 Service Guide Figure 8 21 Removing the PCI Backplane PK0280 3 1 2 2 4 1 ...
Страница 332: ......
Страница 336: ......
Страница 358: ......
Страница 444: ......