A-6
Compaq StorageWorks ESL9000 Series Tape Library Reference Guide
The message name and description might contain abbreviations as follows:
■
Logical Unit (LU)
■
Required (REQ’D)
■
Device (DEV)
■
Diagnostics (DIAG)
■
Nonvolatile RAM (NVRAM)
■
Analog-to-Digital (A/D)
Table A-4 Sense Data Values (Hexadecimal)
Sense
Key
ASC
ASCQ
Message Name/Description
Interface
0
00
00
NO ADDITIONAL SENSE INFORMATION
No recovery necessary.
Both
B
00
00
SCSI ABORT
Command aborted because host sent SCSI Abort
Message.
SCSI
2
04
00
LU IS NOT READY, CAUSE NOT REPORTABLE
Check library power. Retry command.
Both
2
04
01
LOGICAL UNIT IN PROCESS OF BECOMING READY
Wait for library to complete initialization.
Both
2
04
02
LOGICAL UNIT INIT REQUIRED
Element status or calibration unknown. Perform
INITIALIZE ELEMENT STATUS command (SCSI) or
INITIALIZE INVENTORY command (DIAG)
Both
2
04
03
LU IS NOT READY, MANUAL INTERVENTION REQ’D
Initialization failed. Determine failure type by checking
any previous error code returned to host. Correct the
cause of the failure and toggle
Standby
button.
Both
0B
08
00
LOGICAL UNIT COMMUNICATION FAILURE
Check cables. Ensure library is turned on. Retry
command.
SCSI