A-12
Compaq StorageWorks ESL9000 Series Tape Library Reference Guide
4
80
0A
NVRAM CHECKSUM FAILURE
Nonvolatile RAM contents are corrupted. Use the
diagnostic software to initialize nonvolatile RAM and
calibrate library.
Both
B
80
0B
COMMAND ABORTED BY USER
Informational message. No action is necessary.
Both
B
80
0D
CARTRIDGE IS ONLY PARTIALLY GRIPPED (ONLY SEEN IN
THE FRONT SENSOR).
Issue a MOVE MEDIUM command to move the cartridge
from the transfer element to an empty storage element.
Both
6
80
0E
DATA TRANSFER CHANGED
A drive has been inserted into the library. Use Read
Element Status to determine status of drives.
Both
4
80
0F
LOW POWER ERROR
Check power connections.
Both
B
80
10
LOAD RETRY FAILED
Library was unable to successfully load the drive, even
after retries. Check drive alignment. If the problem
continues, drive might need servicing.
Both
4
80
11
MOTOR POWER FAILURE
Indicates motor power turned off for a reason not
otherwise reported. Toggle of the
Stop
button should
clear.
Both
5
80
22
ELEMENT CONTENTS UNKNOWN
The contents of an element address are unknown. Issue
a READ ELEMENT STATUS command for the element
address. If contents are still unknown issue an INITIALIZE
ELEMENT STATUS command.
Both
4
80
23
BAR CODE DECODER COMMUNICATION FAILURE
Unable to initialize decoder. Verify that the decoder is
powered on. Cycle power and/or check cable
connections.
Both
Table A-4 Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description
Interface