Configuring the Integrated
Management Display
The Compaq Integrated Management Display can be configured to display a
variety of menus that can be customized to meet each user’s specific needs. The
following information explains how to configure and customize the Integrated
Display.
Setup with the System
Configuration Utility
After installing the hardware, configure the Integrated Management Display
using the System Configuration Utility located on the Compaq SmartStart and
Support Software CD. It is recommended that this version of System
Configuration be used because it is the latest one that supports the new
Integrated Management Display. To run the utility:
1. Boot the computer from the Compaq SmartStart and Support Software
CD.
2. From the Compaq System Utilities screen select Run System
Configuration Utility.
3. Select
Continue.
4. Select Review or modify hardware settings and press Enter.
5. Select Step 3: View or Edit Details and press Enter.
6. Scroll down until you find the section entitled Embedded Compaq LCD
Module.
7. Highlight the field to be modified. Press Enter to edit the highlighted
item, then type the text for that field. After entering the text, press Enter
to accept the modifications. Each field is discussed in detail later in this
chapter. See “Customizing Management Display Fields.”
8. Repeat step 7 for each menu item to be modified.
9. Press
F10 to exit the View or Edit Details screen.
10. Select Step 5: Save and Exit.