Compaq ProLiant 5500 and 5500R Servers Setup and Installation Guide
For use with Pentium II Xeon and Pentium III Xeon processor-based servers only
Writer: Michele Wray Project: Compaq ProLiant 5500 and 5500R Servers Setup and Installation Guide Comments: 328470-002
File Name: H-CH07.DOC Last Saved On: 2/8/99 11:06 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Example
This section contains an example cabling scenario covering common
applications. If your planned configuration does not match this example, use the
SCSI Cable Matrices in Tables 7-1 and 7-2 and as a general guide.
Example 1:
Using Integrated SCSI Port 1 and Port 2 for
Hard Drives with SCSI Input 1 Connected to
the Removable Media Bay
1. Install the Duplex Enabler Board on the back of the Drive Cage, if not
already installed.
2. Connect 19-inch point-to-point non-terminated SCSI cable (199606-
007), from the SCSI Port 1 to SCSI Input 0 of the duplex board. Connect
another 19-inch point-to-point non-terminated SCSI cable (199606-007)
from SCSI Port 2 to SCSI Input 1 of the duplex board. These
connections are shown in Figures 7-13 and 7-14.
3. Use 22-inch 3-device non-terminated SCSI cable (199616-010),
supplied with server, to connect from the duplex enabler board to the
removable media bay.