Removal and Replacement Procedures
To replace the lithium battery from the system board:
1. Complete the preparation procedures. Refer to “Preparation Procedures” earlier in this
chapter.
2. Remove the front bezel. Refer to “Front Bezel” earlier in this chapter.
3. Remove the access panel. Refer to “Access Panel” earlier in this chapter.
4. Locate the battery on the system board.
NOTE: If you have expansion boards installed, it may be necessary to remove them to gain access to
the battery.
5. Press the latch at the top of the battery holder to release the battery (1), and then lift the
battery away from the holder (2).
1
2
6. Side the replacement battery into the proper position with the positive (+) side up.
Figure 2-31: Locating and removing the battery from the system
board
IMPORTANT: Positive (+) polarity must be positioned up.
7. Replace the server access panel and connect cables to the server.
8. Run RBSU to reconfigure your system by pressing the F9 key when prompted during
server startup. Refer to the Compaq ROM Based Setup Utility User Guide for more
information on RBSU.
2-40
Compaq ProLiant ML330 Generation 2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: Mimic/Reaper Part Number: 234832-003 Last Saved On: 11/25/02 10:18 AM