Removal and Replacement Procedures
Power Switch and LED
IMPORTANT: To completely remove all power from the system, you must disconnect the power cord
from the server.
To remove the power switch:
1. Complete the preparation procedures. Refer to “Preparation Procedures” earlier in this
chapter.
2. Remove the front bezel. Refer to “Front Bezel” earlier in this chapter.
3. Remove the access panel. Refer to “Access Panel” earlier in this chapter.
4. Disconnect the power switch cable from the system board.
Figure 2-16: Disconnecting the power switch cable from
the system board
2-24
Compaq ProLiant ML330 Generation 2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: Mimic/Reaper Part Number: 234832-003 Last Saved On: 11/25/02 10:18 AM