HP Array Configuration Utility 94
Warning
code
Warning message
Comment or clarification
4003
One or more controller commands were
skipped because the controller is not
configured
Certain commands require that the controller be
configured before they can be sent to the controller.
4004
Using Repeat function
Some commands have been ignored because the
Repeat parameter has been specified in the input
file.
4005
The system must be rebooted for the firmware
flash to complete
A controller has been flashed with new firmware.
The new firmware requires a reboot to take effect.
4006
Unable to set the array accelerator for this
volume. The cache board may be missing or
have a bad status, or the controller may not
support a cache
The controller may not support a cache (for
example, some Software RAID controllers) or the
cache may be missing or defective.
ACU scripting error messages
Error code Error message
Comment or clarification
0
—
No error exists. The program completed
successfully.
2053
Too many coinciding expansion, migration,
or extension operations
The new configuration requires more
transformations than are possible at one time. For
example, you cannot expand a logical volume and
transform its RAID level at the same time.
2056
Controller does not support license keys
The controller does not support license key entry or
deletion.
2059
Invalid license key
The entered license key is not a valid license key.
2064
Controller does not support SSP
The controller does not support SSP functions.
2817
Invalid Action
The requested actions are invalid, for example,
combining
-reset
with capture mode.
2818
Invalid Method
The method must be either Custom or Auto.
2819
Invalid Controller
An invalid controller value was specified.
2821
No controllers detected
No controllers were detected. This error applies to
Input mode only.
2823
Invalid Rebuild Priority
The specified rebuild priority is not supported.
2824
Invalid Expand Priority
The specified expand priority is not supported. This
error also occurs if the controller does not allow
expansion, and therefore does not support expand
priority.
2825
Invalid Array
The array ID is invalid.
2826
Array not specified
The Array command is missing from the script file.
Some commands were found that require an Array
to be specified.
2827
New Array ID does not match the next
available Array ID.
The array ID in the script file does not match the
array ID of the next available array. For example, if
the configuration has an Array A and the input file
specifies Array C (without Array B), then the script
generates this error.
2828
New Array ID already exists
The array ID specified in the script file (in Configure
mode) already exists in the configuration. Configure