ORIGINAL INSTRUCTIONS | Ref. quality process 002/03 | v. 12/02/2021 | K07173H01
23
9.4.
PRESELECT MODE
In the PRESELECT mode, a pre-
programmed single, double or triple
dose can be set by simple pressing the
corresponding icon on the LCD screen ( ).
The preselection of a single, double or triple
dose will remain active until it is changed
by pressing one of the three numbered
preselect icons. This preselection is
reflected on the LCD screen ( ) with
the icon of the active selection in the
secondary color, and the rest of the icons in
the principle color.
Dispensing the preselected dose by
pressing the lower pulse button ( ) one
time. When the grinding cycle begins, a
timer countdown will begin on the LCD
screen ( ), which will count down the
timed dose cycle to zero.
Once the grind cycle is initiated, it can be
paused by pressing the lower activation
button ( ). The cycle will pause, and will
complete the timed grind cycle as long
as the lower activation button is pressed
again within 10 seconds. After 10 seconds
of inactivity, the grind cycle will reset to the
complete cycle time.
Grind pause can be activated or
deactivated by pressing the lower pulse
button ( ). First, set up by following these
steps:
MENU / SET UP SETTINGS / SET
UP GRIND PAUSE.
In this mode, pause grinding may also be
performed by pressing the active icon on
the LCD display ( ). This pause cannot be
enabled or disabled via the MENU.
* Available only for the 3 dose software option.
9.5.
INSTANT MODE
In this operating mode, the selection of one,
two or three * doses of coffee is made by
making a single touch of the corresponding
numerical icon of the LCD screen ( ).
Once the dose has been selected, grinding
starts without the need to press the lower
coffee dose button ( ).
The time set for that dose will decrease
until it reaches zero, at which time the dose
ends.
Once the grinding cycle has started, if the
lower coffee dose button ( ) is pressed,
grinding will stop. If in the next 8 seconds
it is pressed again, the remaining time
to complete the requested dose will be
completed.
After 8 seconds of inactivity, it returns to
sleep mode.
9.
OPERATION
Содержание PKE
Страница 1: ...INSTRUCTIONS MANUAL COFFEE GRINDER PKE...
Страница 2: ...ORIGINAL INSTRUCTIONS Ref quality process 002 03 v 12 02 2021 K07173H01 2...
Страница 15: ...ORIGINAL INSTRUCTIONS Ref quality process 002 03 v 12 02 2021 K07173H01 15 Fig 2 8 REGULATION Coarse Fine...
Страница 40: ...ORIGINAL INSTRUCTIONS Ref quality process 002 03 v 12 02 2021 K07173H01 40 NOTES...
Страница 41: ...ORIGINAL INSTRUCTIONS Ref quality process 002 03 v 12 02 2021 K07173H01 41 NOTES...