CompAir Limited
page 36
4.1.4 To Drain the Oil
The compressor must be stopped.
Drain the oil while the compressor is hot. The hot oil
will run freely and carry out any suspended
particles.
1.
Remove the oil filler cap.
2.
Place a container beneath the crankcase
drain, remove the drain plug and allow the oil to
drain into the container for disposal. Clean and
refit the drain plug.
3.
Refit the oil filler cap.
4.2 Air Intake Filter
In normal circumstances the air intake filter element
should be checked after every 2,500 hours service.
If the compressor is operating in adverse conditions,
such as high dust levels, more frequent attention
may be necessary .
4.2.1 To Remove the Air Filter Element
The compressor must be stopped.
1.
Unscrew the wingnut or slot-headed nut
securing the air intake cover and remove the
cover.
2.
Remove the filter element.
3.
Clean out the inside of the intake silencer.
4.2.2 To Clean the Element by Air Blast
The compressor must be stopped.
1.
Using an air line supplying dry, low-pressure air
(max. 5 bar) carefully blowout the inner cavity
of the element, ensuring that the air stream
passes through the element from inside to
outside.
2.
When all contamination has been removed,
inspect the element for cracks, holes or other
damage by viewing the light from a hand lamp
through the element or holding the element up
against a light source.
3.
If any damage is evident the element must be
discarded and a new one fitted.
4.
Re-install the clean/new element in the intake
silencer.
Содержание EO40/0001
Страница 12: ...CompAir Limited page 10...
Страница 16: ...CompAir Limited page 14...
Страница 17: ...page 15 V100 VL400 User Manual 3 LEADING PARTICULARS...
Страница 39: ...page 37 V100 VL400 User Manual 7 FAULT FINDING...
Страница 44: ...CompAir Limited page 42...
Страница 45: ...page 43 V100 VL400 User Manual APPENDIX 1 The Pressure Systems Safety Regulations 2000...
Страница 48: ...CompAir Limited page 46...