INS_RLMCSFP_REV–   

Rev. 18 Sep 2020   PAGE 6

© 2020 Communications Networks, LLC. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC. 

3 CORPORATE DRIVE | DANBURY, CT 06810 | USA 

T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | [email protected]

8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE

T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]

MECHANICAL INSTALLATION INSTRUCTIONS

Installation Considerations

 

This product is supplied as Standalone/Surface Mount module. Units should be installed in dry locations protected from extremes of temperature and humidity.

WARNING

: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS: 

A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than 

room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) 

specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

Figure A

Dimensions and mounting methods for a ComNet Reliance mini DIN Rail module

Table 7 – Troubleshooting Guide

Problem

Steps to Take

Power LED not lighting

Check that power is properly applied to the unit using the correct connector pair.

No Communication

Check Ethernet Link LEDs, Fiber Optic Link LEDs. Confirm Connections, DIP switches are set properly. Verify that the Data Rate switches are set 

to the same data rate on back-to-back units and match the installed SFP. Restart the unit if the Data Rate Switch or installed SFP has changed.

PoE LED not lighting

Ensure a Powered Device (PD) is properly connected and verify 48 V input to RLMCSFPPOEHO.

PoE not supplying  

appropriate power levels

Check power supply and confirm it has the power capability to drive RLMCSFPPOEHO and network device.

Содержание RLMCSFP Series

Страница 1: ...electable link fault pass through provides remote indication of a network fault and a summary fault alarm provides a local or remote indication via Form C dry contact closure in the event of loss of optical link or operating power The 10 100 1000BASE TX port supports both auto negotiation and automatic MDI MDI X crossover for full and half duplex operation manual MDI MDI X switching is not require...

Страница 2: ...lation Instructions Step 6 3 10 100 1000 TX RJ 45 Port 1 and Port 1 Link Activity L A and Speed LED Indicators See Installation Instructions Step 8 See Table 6 Indicating LEDs 4 SFP Port Link Status and SFP Port Link Speed LED Indicators See Table 5 Indicating LEDs 5 Power LED Indicator See Table 5 Indicating LEDs 6 User selectable DIP Switches See Installation Instructions Steps 1 2 See Table 3 D...

Страница 3: ...1 Link Activity L A and Speed LED Indicators See Installation Instructions Step 8 See Table 6 Indicating LEDs 4 SFP Port Link Status and SFP Port Link Speed LED Indicators See Table 5 Indicating LEDs 5 Power LED Indicator See Table 5 Indicating LEDs 6 Power over Ethernet PoE LED Indicator for Port 1 See Table 5 Indicating LEDs 7 User selectable DIP Switches See Installation Instructions Steps 1 2 ...

Страница 4: ...SWITCHES UTP MODELS ONLY FOR COAX MODELS SKIP TO STEP 3 Locate the LFE FFE and PSE DIP switches on the bottom panel of the unit LFE1 If the Copper Port is Down or Not Connected the Optical Port will turn on and off at a 1 sec rate to indicate copper port fault and the alarm relay will be triggered FFE If the optical link is lost or there is a power failure then the alarm relay output will be trigg...

Страница 5: ...ng transmitted 1000 Mbps No Fault NC COM Power Applied Flashing Fiber failure or copper failure Link Fault Enable must be switched set to ON Dim 30 W Mode Bright 60 W Mode RED Solid 100 Mbps Fault NO COM OFF Communication link has not been established Unit is not correctly powered up or DIP Switch incorrectly set Reset power after switch change Unit is not correctly powered up Unit is not correctl...

Страница 6: ...tion should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Figure A Dimensions and mounting methods for a ComNet Reliance mini DIN Rail module T...

Отзывы: