INSTALLATION AND OPERATION MANUAL 

RLMCSFP SERIES

INS_RLMCSFP_REV–   

Rev. 18 Sep 2020   PAGE 5

INSTALLATION AND OPERATION MANUAL 

RLMCSFP SERIES

7 -   CONNECT POWER

Connect power to unit per the following table. 

Table 3 – Power Connections per Use Case

 

RLMCSFP24DC

RLMCSFP48DC

RLMCSFPHV

RLMCSFPPOEHO

Operating Voltage

Redundant Inputs

9 to 36 VDC (max)

Redundant Inputs

36 to 59 VDC (max)

88 to 300 VDC (max)

OR

85 to 264 VAC (max)

Redundant Inputs 

44 to 57 VDC (max)

Use Power Connectors

Vin1+ and Vin1- for PS 1

Vin2+ and VIN2- for PS 2

Vin1+ and Vin1- for PS 1

Vin2+ and VIN2- for PS 2

+/L, -/N,  

and Earth GND

Vin1+ and Vin1- for PS 1

Vin2+ and VIN2- for PS 2

Contact the ComNet Design Center, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.

8 -   VERIFY FUNCTIONALITY

See LED Indicator table below and Troubleshooting Guide if corrective action is needed.

Table 4 – Front Panel LED Indicators

SFP Link

SFP Speed

Fault

Power

PoE

GREEN Solid

Communication link has been established 

over optical fiber. Flashes when data is 

being transmitted.

1000 Mbps

No Fault (NC-

COM)

Power Applied

Flashing

Fiber failure or copper failure (Link Fault 

Enable must be switched set to ON)

Dim

30 W Mode

Bright

60 W Mode

RED

Solid

100 Mbps

Fault (NO-COM) –

-

OFF

Communication link has not been 

established.

Unit is not correctly powered up or DIP 

Switch incorrectly set. 

(Reset power after switch change.)

Unit is not 

correctly 

powered up

Unit is not 

correctly 

powered up

-

Figure 5

 – 

Electrical Port

Ethernet

Speed

Ethernet

Link / 

Activity

 

Installation Instructions (Continued)

Figure 6 - Fault Relay Operation

The fault relay is normally closed and will open on any of the following alarm conditions:
-  Link Fault is enabled on the 

remote

 RLMCSFP unit and the corresponding copper port has been 

disconnected.

-  Link Fault is enabled on the 

local

 RLMCSFP unit and the corresponding copper port has been 

disconnected.

-  Fiber Fault is enabled on the 

local

 RLMCSFP unit and the fiber link is down or the power has been lost to 

either the local or remote RLMCSFP unit. 

Table 5 – Electrical Port LED Indicators

Link / Activity

Speed

GREEN

Solid

Communication link has been established over the electrical cable

Flashing

Data is being transmitted over the electrical cable

YELLOW

1000 Mbps Speed

OFF

Communication link has not been established.

10/100 Mbps Speed

Содержание RLMCSFP Series

Страница 1: ...electable link fault pass through provides remote indication of a network fault and a summary fault alarm provides a local or remote indication via Form C dry contact closure in the event of loss of optical link or operating power The 10 100 1000BASE TX port supports both auto negotiation and automatic MDI MDI X crossover for full and half duplex operation manual MDI MDI X switching is not require...

Страница 2: ...lation Instructions Step 6 3 10 100 1000 TX RJ 45 Port 1 and Port 1 Link Activity L A and Speed LED Indicators See Installation Instructions Step 8 See Table 6 Indicating LEDs 4 SFP Port Link Status and SFP Port Link Speed LED Indicators See Table 5 Indicating LEDs 5 Power LED Indicator See Table 5 Indicating LEDs 6 User selectable DIP Switches See Installation Instructions Steps 1 2 See Table 3 D...

Страница 3: ...1 Link Activity L A and Speed LED Indicators See Installation Instructions Step 8 See Table 6 Indicating LEDs 4 SFP Port Link Status and SFP Port Link Speed LED Indicators See Table 5 Indicating LEDs 5 Power LED Indicator See Table 5 Indicating LEDs 6 Power over Ethernet PoE LED Indicator for Port 1 See Table 5 Indicating LEDs 7 User selectable DIP Switches See Installation Instructions Steps 1 2 ...

Страница 4: ...SWITCHES UTP MODELS ONLY FOR COAX MODELS SKIP TO STEP 3 Locate the LFE FFE and PSE DIP switches on the bottom panel of the unit LFE1 If the Copper Port is Down or Not Connected the Optical Port will turn on and off at a 1 sec rate to indicate copper port fault and the alarm relay will be triggered FFE If the optical link is lost or there is a power failure then the alarm relay output will be trigg...

Страница 5: ...ng transmitted 1000 Mbps No Fault NC COM Power Applied Flashing Fiber failure or copper failure Link Fault Enable must be switched set to ON Dim 30 W Mode Bright 60 W Mode RED Solid 100 Mbps Fault NO COM OFF Communication link has not been established Unit is not correctly powered up or DIP Switch incorrectly set Reset power after switch change Unit is not correctly powered up Unit is not correctl...

Страница 6: ...tion should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Figure A Dimensions and mounting methods for a ComNet Reliance mini DIN Rail module T...

Отзывы: