INS_RL1000GW_REV– 15 Jul 2016 PAGE 185
INSTALLATION AND OPERATION MANUAL
RL1000GW
TECH SUPPORT: 1.888.678.9427
Adding a transparent serial tunneling service
Hub :
1. Create the serial port and transparent serial tunneling service
application connect
serial port create slot 1 port 1 mode-of-operation transparent
serial local-end-point create slot 1 port 1 service-id 2 application serial-tunnel
position master
serial remote-end-point create remote-address 192.168.40.10 service-id 2 position slave
exit
write startup-cfg
Spoke :
1. Create the serial port and transparent serial tunneling service
serial port create port 2 mode-of-operation transparent
serial local-end-point create port 2 service-id 2 application serial-tunnel position slave
serial remote-end-point create remote-address 192.168.10.10 service-id 2 position master
commit
Testing the setup:
1. From the SCADA send serial traffic over its COM port.
2. The remote serial device at the spoke will respond