8
6.2.6
Store fibers on the tray properly.
6.2.7
Remove/Install tray 48 as following shows
6.3
When using Tray 12 (Thin tray)
6.3.1
Same as 6.1.1
6.3.2
Same as 6.1.2
6.3.3
Degrease the fiber bundle. Slide the thicker
transportation tubes over the fibers up to 50 mm from the cable
jacket end and then insert the thinner transportation tube into the
thicker one with overlap 30mm (see drawing 6.2.4).
6.3.4
Sketch for tube installation.
6.3.5
Same as 6.1.5
6.3.6
Insert the thinner transportation tube to the splice tray
entrance directly.
7
7.1
Splicing and fiber storage
Position the
SCIL-B
close to the splicing machine
in a convenient location and secure the closure.
7.2
Slide the heat-shrinkable splice protection over one
fiber and fuse fibers according to local recommendations and
procedures. After the fusion splice is made, install the heat-
shrinkable splice protection (e.g. SMOUV) with an appropriate
heating source. Allow the splice protection to cool down to
ambient temperature.
7.3
After each splice is made, the splice should be stored
in the splice holder in the appropriate position. Do not deform the
splice protector during insertion.
7.4
Incoming fibers should be routed first behind the splice
holder before the over-length is coiled into the tray. Route the
fibers through the cross of the tray as shown.
30mm
Thinner tube
Содержание SCIL-B
Страница 11: ...11 ...