Connector Sealing Instructions

NOTE: N-Type connectors shown are representative examples.

NOTE: Applying sealing tape to both ends of the cable is recommended.

Step 1: Cleaning the Connectors and Your Hands

1. Clean all traces of dust, grease, and oil from your hands
2. Clean off any traces of dust, grease, and oil from the N-type bulkhead

connector external threads

3. Make sure that the connectors are dry before continuing.

Step 2: Connecting the Cable with the Connector

1. If the AP is powered on, disconnect the AP from the power source.

CAUTION! Make sure that you disconnect the AP from the power

source to avoid electrocution or equipment damage.

FIGURE 12  Connecting the Cable with the Connector

2. Unscrew the metal cap that protects the antenna connector. Place the

metal cap in a safe place, in case you need it later.

3. Connect the cable to the connector. Use a torque wrench to tighten

the cable coupling nut to 1.58 N.m (14 in-lb). If you do not have a

torque wrench or if you are tightening a knurled coupling nut (as

shown), hand-tighten the cable coupling nut until the internal gaskets

are compressed, but do not overtighten.

Step 3: Wrapping the Exposed Connector Threads

1. Depending on the width of the sealing tape, either fold the tape in

half or cut it to fit the exposed connector threads

2. Stretch the tape per the manufacturer’s instructions
3. Working clockwise, gently stretch the sealing tape as you install it so

that it covers the connector thread between the cable coupling nut

and the base of the connector.
Make sure that the final wrap is approximately flush with the cable

coupling nut, and then cut the sealing tape.

FIGURE 13  Wrapping the Exposed Connector Threads

NOTE: Cut, do not tear, the sealing tape. If the sealing tape is

overstretched, it loses its self-amalgamating properties.

Step 4: Wrapping the Internal Layer of the Electrical

Tape

1. Using scissors, cut the end of the electrical tape at an angle. This will

allow the electrical tape to be applied with minimal bulk.

FIGURE 14  Cutting the End of the Electrical Tape

2. Wrap the electrical tape clockwise from the beginning of the cable

coupling nut to just past the heat shrink tube on the cable. Do not

cover the sealing tape installed in 

Step 3: Wrapping the Exposed

Connector Threads

 on page 5.

FIGURE 15  Wrapping the Electrical Tape

Step 5: Wrapping the Main Sealing Tape

1. Using scissors, cut the end of the sealing tape at an angle. This will

allow the sealing tape to be applied with minimal bulk.

FIGURE 16  Cutting the Sealing Tape at an Angle

2. Working clockwise, gently stretch the sealing tape from the beginning

of the sealing tape installed in 

Step 3: Wrapping the Exposed

Connector Threads

 on page 5 and continue wrapping to 12 mm (0.5

in.) past the electrical tape installed in 

Step 4: Wrapping the Internal

Layer of the Electrical Tape

 on page 5.

NOTE: Cut, do not tear, the sealing tape. If the sealing tape is

overstretched, it loses its self-amalgamating properties.

Copyright 

©

 2020 CommScope, Inc. All rights reserved.

Page 5 of 7

Published July 2020, Part Number 800-72283-001 Rev B

Содержание RUCKUS

Страница 1: ...ireless com warranty Before deploying your RUCKUS WIRELESS Access Point verify that all items listed in Package Contents are included in the package If any item is damaged or missing notify your authorized RUCKUS WIRELESS sales representative Also make sure that you have the required hardware and tools Required Hardware and Tools 1 2 13 mm flat blade screwdriver or equivalent No 2 Phillips screwdr...

Страница 2: ...gland base 8 Tighten the cable gland dome to 7 in lbs The SFP module is hot swappable and can be removed with fingers or simple tools Connecting the SFP Optic Module Using a Zipcord Cable You can use a zipcord cable to connect to the SFP optic module WARNING The zipcord fiber cable is extremely fragile and must be handled with care NOTE Do not insert the cable gland base grommet dome into the exte...

Страница 3: ...tical pole 4 Continue with Mounting the Linkage Bracket to the U Joint Bracket on page 3 Mounting the Linkage Bracket to the U Joint Bracket 1 The linkage bracket attaches to the U joint bracket using an M8 bolt and washer set The linkage bracket is symmetrical and either end can be attached to the U joint bracket NOTE Make sure that linkage bracket is installed with its serrated external tooth lo...

Страница 4: ... 6 N m 120 in lbs 3 Continue with Powering the AP with AC on page 7 External Antenna and Cabling Need to be Purchased Separately If the External Antenna option is chosen over the internal sector antenna the External Antenna and Antenna Cable must be purchased separately NOTE Beamflex is not available with external antennas Mounting and Connecting 5 GHZ and 2 5 GHZ External Antennas NOTE Mount the ...

Страница 5: ...t covers the connector thread between the cable coupling nut and the base of the connector Make sure that the final wrap is approximately flush with the cable coupling nut and then cut the sealing tape FIGURE 13 Wrapping the Exposed Connector Threads NOTE Cut do not tear the sealing tape If the sealing tape is overstretched it loses its self amalgamating properties Step 4 Wrapping the Internal Lay...

Страница 6: ...p Loops Physically mount the AP and antennas at your desired location preferably on the same mounting structure Form 80 mm to 130 mm 3 in to 5 in drip loops with the cables FIGURE 21 Creating Cable Drip Loops Earth Grounding the AP CAUTION Make sure that earth grounding is available and that it meets local and national electrical codes For additional lightning protection use lightning rods and lig...

Страница 7: ...n the cable itself 2 in Figure 12 2 Attach the safety cable to the AP 3 in Figure 12 FIGURE 24 Attaching the security cable Troubleshooting CAUTION If required you can reset the AP to its factory default settings by pressing the reset button located inside the PoE IN port Use the tip of a pen or a 3mm flat blade screwdriver to press the reset button Press and hold the reset button for 4 seconds to...

Страница 8: ... of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars could cause interference and or damageto LE LAN devices Opération dans la bande 5600 5650 MHz n est pas autorisée au Canada Haute puissance radars sont désignés comme utilisateurs principaux c à utilisateurs prioritaires des bandes 5250 5350 MHz et 5650 5850 MHz et que ces radars pourraient causer des interférences et ou des domma...

Страница 9: ...d the user shall cease operatingimmediately until no interference is achieved The said legal communications means radio communications is operated in compliance with the Telecommunications Act The low power radio frequency devices must not be susceptible with the interference from legal communications or ISM radio wave radiated devices 限用物質含有情況標示聲明書 設備名稱 無線網路基地台 型號 型式 T750 T750SE Equipment name Ty...

Страница 10: ... requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014 53 EU Latviski Latvian Ar šo Ruckus Wireless deklarē ka Radio LAN atbilst Direktīvas 2014 53 EU būtiskajām prasībām un citiem ar to saistītajiem noteikumiem Lietuvių Lithuanian Šiuo Ruckus Wireless deklaruoja kad šis Radio LAN atitinka esminius reikalavimus ir kitas 2014 53 EU Direktyvos nuostatas Nederlands...

Страница 11: ...e earth the device operates in compliance with FCC rules without any adjustment of output power T750 T750SE Antennas When the device is installed outdoors at an angle above the horizon it may be necessary to reduce output power to insure the energy radiated above 30 from the horizon remains under 21 dBm EIRP Please see table and elevation plots below T750 Omni Antenna 3 4dBi Vertical Polarity Elev...

Отзывы: